• Title/Summary/Keyword: power distribution

Search Result 6,652, Processing Time 0.035 seconds

A Study on Configuration of Electrical Power Distribution System for Railway (철도 배전 계통의 최적 구성 방안에 대한 연구)

  • Lee, Gyu-Dae;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.17-21
    • /
    • 2011
  • Since the railway passenger services have been recognized as important factor for success in railway, electrical energy consumption in railway station for high quality service has greatly increased. Furthermore, the number of the private railway station has gradually increased. Therefore, the operation conditions for railway power distribution system is dramatically changed in comparison with the past. So, this paper proposes the optimal construction method for railway power distribution system considering economical efficiency and the reliability of power supply to establish the railway power distribution system standard for the future railway industry.

  • PDF

Development of Wireless Monitoring System for Distribution Transformer (배전용 변압기의 무선 부하감시 시스템 개발)

  • Jung, Joon-Hong;Kang, Tae-Goo;Kim, Il-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.414-415
    • /
    • 2008
  • In this paper, we consider the development methodology of wireless monitoring system for a distribution transformer. The master/ slave devices are installed in the power distribution feeder and measure the current state of pole or ground transformers. After measuring, the devices send the measurement data to operating room through the wireless network such as RF and CDMA so that the power distribution supervisor can prevent a distribution transformer damaging caused by overloads and imbalance of loads.

  • PDF

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

Development of Intelligence Power Distribution Module with Control Area Network (CAN 통신을 이용한 IPDM(intelligence power distribution module) 개발)

  • Lee D.K.;Ko K.W.;Koh K.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.37-38
    • /
    • 2006
  • In this paper, power distribution module for car relay control with Control area network is developed. This module is called Intelligent power distribution module because it has microprossor which can communicate with other electric module such as ECU and Body control module and also has self-diagonasis function. The developed IPDM module is tested on vehicle and the good performance has been achieved.

  • PDF

A Study on Residential Hybrid Distribution System for Reducing Power Conversion Loss (전력 변환 손실 저감을 위한 하이브리드 주거배전시스템)

  • Byen, Byeng-Joo;Seo, Hyun-Uk;Choi, Jung-Muk;Lee, Young-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.413-421
    • /
    • 2013
  • This paper proposes residential hybrid distribution system that can supply AC power and DC power to AC load and DC load at the same time. This hybrid distribution system consists of three parts: bidirectional inverter, step-up converter and step-down converter. Also that is used to supply voltage to home application is classified of AC load and DC load as load characteristics. The performance of proposed hybrid distribution system is validated through the hardware implementation and the experimental results.

Consideration of the Distributed Generator's Capacity in Determining the Protective Devices (배전선 보호기기 선정 시 계통 연계 분산전원의 용량 고려)

  • Park, I.K.;Jang, S.I.;Park, Y.U.;Kim, S.G.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.331-333
    • /
    • 2003
  • This paper describes the effect of the interconnected wind turbine generators on fault current level of distribution networks. Distributed generator(DG) interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with DG, the fault current level measured in a relaying point might be higher than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may destroy the conventional protective devices applied in the distribution network with DG. Simulation results shows that the current level of fault happened in the power line with DG depends on the power output of DG.

  • PDF

A Study on Computer Application Program to an Efficient Supervisory Control of the Power Distribution System (효율적인 배전관리를 위한 컴퓨터 응용 프로그램 연구)

  • Lee, B.C.;Seo, Y.R.;Lee, J.H.;Chung, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.96-98
    • /
    • 1993
  • In accordance with increase of electrical power demanded, more efficient supervisory control of distribution system is required. This study contains development of MMI(man-machine-interface) system with GUI(graphic-user-interface), for the automatic power distribution system. The main function of MMI system are to edit network of power distribution, to view network, to warnning a breakdown and to management of data base for network. The GUI function of MMI system enables more efficient management of power distribution system.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

The Relationship between Interdependence on Relational Satisfaction in Cosmetics Distribution Channels: Moderating Effect of Communication and Mediating Effect of Non-coercive Power

  • Sun, Il-Suck;Yang, Hoe-Chang
    • The Journal of Economics, Marketing and Management
    • /
    • v.4 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • This study tried to examine how interdependence, communication, and the exercise of power in cosmetics distribution channel would affect satisfaction. In this study we investigated the effects of their communication and the exercise of noncoercive power of department store (or mart). We conducted with managers of the shops which were entered to department store (or mart). 131 copies were collected and 119 copies were used for analysis after the exclusion of 12 copies. Brand image and sales policy influenced satisfaction, but customers were not statistically significant. In addition, communication in distribution path had the moderating effect on the relationship between interdependence and satisfaction, and on the relationship between interdependence and noncoercive power. Sales policy and brand image in the relationship between department store(or mart) and the shops opened inside are critical factors for satisfaction, but customers are highly likely to become a factor with different meaning.

A Study on the Variation of Power Factor by Connection of the Induction Generator to the Distribution Line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.159-163
    • /
    • 2015
  • Recently squirrel cage induction generator has been steadily applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed that how the increase or decrease of D/L load impacts at the change of power factor and power flow.