Differential Power Analysis on Countermeasures Using Binary Signed Digit Representations

  • Kim, Tae-Hyun;Han, Dong-Guk;Okeya, Katsuyuki;Lim, Jong-In
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.619-632
    • /
    • 2007
  • Side channel attacks are a very serious menace to embedded devices with cryptographic applications. To counteract such attacks many randomization techniques have been proposed. One efficient technique in elliptic curve cryptosystems randomizes addition chains with binary signed digit (BSD) representations of the secret key. However, when such countermeasures have been used alone, most of them have been broken by various simple power analysis attacks. In this paper, we consider combinations which can enhance the security of countermeasures using BSD representations by adding additional countermeasures. First, we propose several ways the improved countermeasures based on BSD representations can be attacked. In an actual statistical power analysis attack, the number of samples plays an important role. Therefore, we estimate the number of samples needed in the proposed attack.

  • PDF

Tsunami Hazard Evaluation for the East Coast of Korea by using Empirical Tsunami Data (경험자료에 의한 동해안의 지진해일 재해도 평가)

  • Kim, Min-Kyu;Choi, In-Kil;Kang, Keum-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2010
  • In this study, a tsunami hazard curve was determined for a probabilistic safety assessment (PSA) of a tsunami event at a Nuclear Power Plant site. A Tsunami catalogue was developed by using the historical tsunami record prior to 1900 and the instrumental tsunami record after 1900. For the evaluation of the return period of the tsunami run-up height, power-law, upper-truncated power law and exponential function were considered for the assessment of regression curves and each result was compared. Although there were in total only 9 tsunami records on the east coast of Korea during the time period of the tsunami catalogue, there is no research like this about tsunami hazard curve evaluation, so this research lays a foundation for probabilistic tsunami hazard assessment (PTHA)

Valve core shapes analysis on flux through control valves in nuclear power plants

  • Qian, Jin-yuan;Hou, Cong-wei;Mu, Juan;Gao, Zhi-xin;Jin, Zhi-jiang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2173-2182
    • /
    • 2020
  • Control valves are widely used to regulate fluid flux in nuclear power plants, and there are more than 1500 control valves in the primary circuit of one nuclear power plant. With their help, the flux can be regulated to a specific level of water or steam to guarantee the energy efficiency and safety of the nuclear power plant. The flux characteristics of the control valve mainly depend on the valve core shape. In order to analyze the effects of valve core shapes on flux characteristics of control valves, this paper focuses on the valve core shapes. To begin with, numerical models of different valve core shapes are established, and results are compared with the ideal flux characteristics curve for the purpose of validation. Meanwhile, the flow fields corresponding to different valve core shapes are investigated. Moreover, relationships between the valve core opening and the outlet flux under different valve core shapes are carried out. The flux characteristics curve and equation are proposed to predict the outlet flux under different valve core openings. This work can benefit the further research of the flux control and the optimization of the valve core for control valves in nuclear power plants.

RSSI-Based Indoor Localization Method Using Virtually Overlapped Visible Light (가상 가시광 중첩을 이용한 RSSI 기반의 실내 측위법)

  • Kim, Dae Young;Yi, Keon Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1697-1703
    • /
    • 2014
  • In this paper, we propose an indoor RSSI (received signal strength indication)-based localization method that uses virtually overlapped visible light with an indoor LED lighting system. In our system, a photodiode (PD) measures the RSSI from LED lamps that blink in one row or column units. Subsequently, the RSSI is used to obtain the horizontal distances between the LED lamps and the receiver with the predetermined characteristics curve, R-D curve, that represents the relation between the RSSI and the horizontal distances. When the controlled LED lamps blink in one row or column units, the R-D curve at the border of the LED lamps is different because of the weak lighting, which results in the position sensing error of the receiver. The deviation of the optical power of each LED also causes the error. To solve these problems, we propose a method that overlaps the visible light through the numerical operation at the receiver side without any modification of the light source side. Our proposed method has been simulated in a room measuring $1.2{\times}1.2{\times}1.8m^3$ considering the effect of the error on the optical power of the LED. The simulation result shows that the proposed method eliminates the error condition with the R-D curve and achieves an average positioning error of 13.4 mm under the error rate 3% of the optical power.

Differential Power Analysis Attack on Cryptosystem adopted NAF Algorithm as a Secret Key Recoding Method (비밀키를 NAF로 사용하는 암호시스템의 차분 전력분석 공격)

  • Ahn Mahn-Ki;Ha Jae-Cheol;Lee Hoon-Jae;Moon Sang-Jae
    • Journal of Internet Computing and Services
    • /
    • v.4 no.3
    • /
    • pp.1-8
    • /
    • 2003
  • The power analysis attack is a physical attack which can be applied to the cryptosystems such as smartcard. We try to experimental attack to a smart card which implemented Elliptic Curve Cryptosystem adopting NAF algorithm as a secret key recording method. Our differential power analysis attack is a potential threat to that implementation. The attacker measures the power traces during the multiplication with secret key bits in a target smart card and the multiplication with the guessed bits in other experimental one. The comparison of these two traces gives a secret bit, which means that attacker can find all secret key bits successively.

  • PDF

Soil Ionization Phenomena around a Hemispherical Electrode Stressed by Impulse Voltages (임펄스전압에 의한 반구형 전극계에서 토양의 이온화 현상)

  • Heo, Dae-min;Kim, Hoe-gu;Lee, Bok-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.601-608
    • /
    • 2016
  • The electrical characteristics of the soil where a ground electrode is buried vary with regions, seasons and environmental factors. Electrical discharge in the vicinity of the ground electrode will occur differently and significantly affect the performance of the grounding system. It is necessary to analyze discharge and ionization characteristics of soils when the grounding system is designed. The aims of this investigation are to understand correlation between the soil ionization and the transient ground impedance. This paper presents the experimental results on the soil ionization parameters and the transient ground resistance due to the soil ionization around a hemispherical ground electrode stressed by lightning impulse voltages.

Aero-elastic coupled numerical analysis of small wind turbine-generator modelling

  • Bukala, Jakub;Damaziak, Krzysztof;Karimi, Hamid Reza;Malachowski, Jerzy
    • Wind and Structures
    • /
    • v.23 no.6
    • /
    • pp.577-594
    • /
    • 2016
  • In this paper a practical modelling methodology is presented for a series of aero- servo- elastic- coupled numerical analyses of small wind turbine operation, with particular emphasis on variable speed generator modelling in various wind speed conditions. The following characteristics are determined using the available computer tools: the tip speed ratio as a function of the generator constant (under the assumption of constant wind speed), the turbine coefficient of power as a function of the tip speed ratio (the torque curve is modified accordingly and generator speed and power curves are plotted), turbine power curves and coefficient of power curve as functions of the incoming wind speed. The last stage is to determine forces and torques acting on rotor blades and turbine tower for specific incoming wind speeds in order to examine the impact of the stall phenomena on these values (beyond the rated power of the turbine). It is shown that the obtained results demonstrate a valuable guideline for small wind turbines design process.

The steam turbine condenser pressure optimization with different heat rate correction curves (각기 다른 열소비율 보정곡선을 갖는 증기터빈의 최적 복수기 운전압력 설정)

  • Cho, Cheon-Hwan;Baek, Nam-Ho;Hur, Jin-Hyek;Lee, Jae-Heon;Moon, Seung-Jae;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.224-227
    • /
    • 2008
  • The present study performs a test of a change in a condenser pressure on two kinds of power plants having different condenser pressure-heat rate correction curve and evaluates the results. According to a result of the test, it is confirmed that a sub-critical drum type steam power plant is optimally operated at the condenser pressure of 38㎜Hga that is designed, even during winters. On the other hand, it can be found that a supercritical once through type steam power plant operated at the condenser pressure that is reduced below a design value, that is, up to 28㎜Hga during winters is advantageous in view of turbine efficiency and is operated without a problem in facility operation such as moisture erosion, turbine vibration, etc. Also, the present study compares and reviews a condenser pressure-heat rate correction curve proposed by a manufacturer and a test value. The present study proposes optimum condenser operation pressure capable of concurrently satisfying the stable operation and efficiency improvement of the power plant facility that is operating, making it possible to support an efficient operation of a power plant.

  • PDF

A Study on the Effect of Wind Turbulence Intensity on the Power Performance of Wind Turbine System (풍력발전시스템 출력에 대한 난류강도의 영향 연구)

  • Hyun, Seung-Gun;Ju, Young-Chu;Kim, Keon-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.17-23
    • /
    • 2012
  • The installed capacity of wind turbines in Korea are growing and enlarging by the central government's supporting program. But the majority area having the abundant wind energy resources is composed of mountainous and complex district, thus the turbulence intensity of there is so high and belongs to the turbulence characteristic A category of IEC design requirement. This paper presents the effect of the turbulence intensity on the power performance of a wind turbine system. Particularly, the effect of the power curve of the wind turbine system due to the turbulence intensity has analyzed. As a result, the power curve has a high turbulence characteristic shows the lower value than normal one in high wind speed regime and the AEP will be reduced at the relatively high turbulence area.

An Adaptive Maximum Power Point Tracking Scheme Based on a Variable Scaling Factor for Photovoltaic Systems (태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법)

  • Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok;Lim, Chun-Ho;Kim, Woo-Chull
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.423-430
    • /
    • 2012
  • An adaptive maximum power point tracking (MPPT) scheme employing a variable scaling factor is presented. A MPPT control loop was constructed analytically and the magnitude variation in the MPPT loop gain according to the operating point of the PV array was identified due to the nonlinear characteristics of the PV array output. To make the crossover frequency of the MPPT loop gain consistent, the variable scaling factor was determined using an approximate curve-fitted polynomial equation about linear expression of the error. Therefore, a desirable dynamic response and the stability of the MPPT scheme were maintained across the entire MPPT voltage range. The simulation and experimental results obtained from a 3 KW rated prototype demonstrated the effectiveness of the proposed MPPT scheme.