• Title/Summary/Keyword: power configuration

Search Result 1,621, Processing Time 0.045 seconds

A Study on Optimal Hybrid-Renewable Energy Configuration of Islanded Microgrids (독립형 마이크로그리드에서 신재생에너지 최적구성 알고리즘에 관한 연구)

  • Woo, Sang-Min;Lee, Sung-Hun;Kwag, Hyung-Gun;Kim, Sung-Yul;Son, Hyun-Il;Kim, Jin-O
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.511-515
    • /
    • 2012
  • At the moment, with an interest in renewable energy sources (RES) that continue to grow its penetration will be expected to considerably increase in the future power system. However, this penetration of RES leads to new challenges to be solved in electric power systems. In this paper, optimal configuration of renewable energy resources and operation strategy is presented. By using this methodology for allocation of the optimal sizes and types, system operational efficiency and stability of the microgrid will be maximized.

  • PDF

Comparison of Efficiency of Flash Memory Device Structure in Electro-Thermal Erasing Configuration (플래시메모리소자의 구조에 대한 열적 데이터 삭제 효율성 비교)

  • Kim, You-Jeong;Lee, Seung-Eun;Lee, Khwang-Sun;Park, Jun-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.452-458
    • /
    • 2022
  • The electro-thermal erasing (ETE) configuration utilizes Joule heating intentionally generated at word-line (WL). The elevated temperature by heat physically removes stored electrons permanently within a very short time. Though the ETE configuration is a promising next generation NAND flash memory candidate, a consideration of power efficiency and erasing speed with respect to device structure and its scaling has not yet been demonstrated. In this context, based on 3-dimensional (3-D) thermal simulations, this paper discusses the impact of device structure and scaling on ETE efficiency. The results are used to produce guidelines for ETEs that will have lower power consumption and faster speed.

An Efficient Channel Selection and Power Allocation Scheme for TVWS based on Interference Analysis in Smart Metering Infrastructure

  • Huynh, Chuyen Khoa;Lee, Won Cheol
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.50-64
    • /
    • 2016
  • Nowadays, smart meter (SM) technology is widely effectively used. In addition, power allocation (PA) and channel selection (CS) are considered problems with many proposed approaches. In this paper, we will suggest a specific scenario for an SM configuration system and show how to solve the optimization problem for transmission between SMs and the data concentrator unit (DCU), the center that collects the data from several SMs, via simulation. An efficient CS with PA scheme is proposed in the TV white space system, which uses the TV band spectrum. On the basic of the optimal configuration requirements, SMs can have a transmission schedule and channel selection to obtain the optimal efficiency of using spectrum resources when transmitting data to the DCU. The optimal goals discussed in this paper are the maximum capacity or maximum channel efficiency and the maximum allowable power of the SMs used to satisfy the quality of service without harm to another wireless system. In addition, minimization of the interference to the digital television system and other SMs is also important and needs to be considered when the solving coexistence scenario. Further, we propose a process that performs an interference analysis scheme by using the spectrum engineering advanced Monte Carlo analysis tool (SEAMCAT), which is an integrated software tool based on a Monte-Carlo simulation method. Briefly, the process is as follows: The optimization process implemented by genetic evolution optimization engines, i.e., a genetic algorithm, will calculate the best configuration for the SM system on the basis of the interference limitation for each SM by SEAMCAT in a specific configuration, which reaches the solution with the best defined optimal goal satisfaction.

A Study on the Application Impacts on Korean Power System by Introducing SFCL

  • Kim, Jong-Yul;Park, Heung-Kwan;Yoon, Jae-Young
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.1-6
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154 ㎸ system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying 154 ㎸ Superconducting Fault Current Limiter(SFCL) to 154 ㎸ transmission systems is proceeding with implementation slated for after 2010. In this paper, the resistive and inductive SFCLs are applied to re-duce the fault current in Korean power system and their technical and economic impacts are evaluated. The results show that the application of SFCL can eliminate the need to upgrade the circuit breaker rat-ing and the economic potential of SFCL is evaluated positively.

A Study on the Introduction of Superconducting Cable in Korean Power System (초전도 케이블 계통 적용을 위한 계통 구성 방안 및 적용 대상 고찰)

  • 김종율;윤재영;이승렬
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.8-15
    • /
    • 2003
  • Nowadays, As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS cable has the several useful characteristics such as increased power density, stronger magnetic fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In this paper, we investigate the status of korean power system and underground transmission system. Based on this, the feasibility study on applying HTS cable to korean power system is carried out and then we propose the new power system configuration of metropolitan area with HTS cable. Finally, we can get a conclusion that applying HTS cable to 154kV underground transmission line in metropolitan area such as seoul is very available. In addition, detail applicable cases are investigated; a)replace old conventional cable with HTS cable; b) apply HTS cable to constructing new underground transmission line; c)use HTS cable to resolve overload problem in conventional power system configuration.

Evaluation of the Application Scheme of SFCL in Power Systems

  • Kim, Jong-Yul;Lee, Seung-Ryul;Yoon, Jae-Young
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.221-226
    • /
    • 2004
  • As power systems grow more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154kV system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying a 154kV Superconducting Fault Current Limiter (SFCL) to 154kV transmission systems is proceeding with implementation slated for after 2010. In this paper, SFCL is applied to reduce the fault current in power systems according to two different application schemes and their technical and economic impacts are evaluated. The results indicate that both application schemes can regulate the fault current under the rating of circuit breaker, however, applying SFCL to the bus-tie location is much more appropriate from an economic view point.

Performance Analysis and Automatic Configuration of Threshold on Anti-Pinch System Based on Current Information for Power Windows (전류정보 기반의 파워 윈도우용 안티핀치 시스템의 전류 임계값 자동 설정 및 성능 분석)

  • Park, Seung-Seob;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.63-70
    • /
    • 2017
  • This paper deals with anti-pinch system based on current information which prevents some risks for trapping, squeezing or injury to people in smart window on vehicles. Automatic configuration of current threshold is suggested to recognize pinch states in the current based anti-pinch system. Also, some factors affecting to the squeezing force were analyzed by some experimental results and simulations. The validity of the suggested system was verified to satisfy the strengthened American safety regulation, FMVSS 118-S5, through some experimental results.

New Configuration of 36-pulse Voltage Source Converter Using Pulse-Interleaving Auxiliary Circuit (펄스다중화 보조회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터)

  • Jon Young-Soo;Baek Seung-Taek;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.238-244
    • /
    • 2005
  • This paper proposes a new configuration of 36-pulse voltage source converter which consists of two 6-pulse bridges and a pulse-interleaving auxiliary circuit. The system topology of proposed converter was derived to increase the pulse number of converter output voltage without increasing the number of 6-pulse bridges. The gate pulse generation was analyzed using the theoretical approach of multi-pulse switching converter, The operational feasibility of proposed system was verified by computer simulations with PSCAD/EMTDC software and experimental works with 2kVA hardware prototype. The proposed converter can be widely used for the uninterruptible power supply, the power quality compensator, and the distributed power generation, such as solar and fuel cell power system.

Loss Analysis according to Configuration Method of AC Module Integrated Converter for Photovoltaic System (태양광 발전 시스템용 AC 모듈 집적형 전력변환기의 구성 방식에 따른 손실 분석)

  • Kang, Seung-Hyun;Son, Won-Jin;Ann, Sangjoon;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.311-318
    • /
    • 2020
  • A photovoltaic (PV) system uses an AC module integrated converter (MIC) to operate PV cells at a maximum power point (MPP) and for high efficiency. The MPP of a PV cell varies depending on partial shading conditions, and loss occurs differently according to the configuration method of the PV-MIC. Therefore, this study compares the losses of passive components and power semiconductors according to the partial shading conditions of the PV module. Theoretical loss analysis is performed using parameters for the datasheet and PSIM simulation results. Analysis results verify that the one-stage PV-MIC demonstrates high efficiency.

Pyramidal reaction wheel arrangement optimization of satellite attitude control subsystem for minimizing power consumption

  • Shirazi, Abolfazl;Mirshams, Mehran
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.190-198
    • /
    • 2014
  • The pyramidal reaction wheel arrangement is one of the configurations that can be used in attitude control simulators for evaluation of attitude control performance in satellites. In this arrangement, the wheels are oriented in a pyramidal configuration with a tilt angle. In this paper, a study of pyramidal reaction wheel arrangement is carried out in order to find the optimum tilt angle that minimizes total power consumption of the system. The attitude control system is analyzed and the pyramidal configuration is implemented in numerical simulation. Optimization is carried out by using an iterative process and the optimum tilt angle that provides minimum system power consumption is obtained. Simulation results show that the system requires the least power by using optimum tilt angle in reaction wheels arrangement.