• 제목/요약/키워드: power change

검색결과 5,095건 처리시간 0.038초

자동변속기내 유성기어비 변화에 의한 동력전달계의 동적특성 (Dynamic Characteristics of Automatic Transmission System Due to the Change of Planetary Gear Ratio)

  • 박영일;김영석
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.120-127
    • /
    • 1998
  • In this study the dynamic characteristics of automatic transmission system due to the change of the planetary gear ratio is studied. To study the power flow and shift quality for power transmission the simulation program is developed using the modeling and analysis technique. The results from this study will be used in designing the basic structure of automatic transmission using planetary gear system.

  • PDF

CO2 배출량을 감안한 화력발전소의 생산성 변화 분석: Luenberger지수 접근법 (CO2 Emission and Productivity of Fossil-fueled Power Plants: A Luenberger Indicator Approach)

  • 권오상
    • 자원ㆍ환경경제연구
    • /
    • 제19권4호
    • /
    • pp.733-752
    • /
    • 2010
  • 본고는 한국의 화력발전소의 생산성 변화율 자체와 그 변화행태와 발전유형별 분포, 그리고 생산성 변화의 구성요소 등을 $CO_2$ 배출량을 감안하여 분석하며, 그러한 분석목적을 달성하는 데 매우 유용한 Luenberger지수를 비모수적 기법을 이용해 도출하는 방식으로 연구를 진행한다. 분석결과 $CO_2$ 배출량을 감안하지 않을 때에는 생산성 변화율이 상당한 정도 왜곡된 형태로 나타날 수 있음이 확인되었다. 특히 발전소의 경우 가동률 차이가 생산성 지표에 큰 영향을 미치게 되는데, $CO_2$ 배출량을 감안하지 않으면 주로 가동률 차이에 의한 생산량 변화가 생산성 변화율에 영향을 미치게 되고, 그 결과 생산성 변화율 계측치가 비상식적으로 높거나 낮게 되는 현상이 발견되었다. 아울러 분석기간 동안 $CO_2$의 배출량이 늘어났기 때문에 이를 반영하지 않고 생산성 증가율을 계측하면 생산성 증가율을 과대평가하게 됨도 밝혀졌다. $CO_2$를 모형에 포함하느냐의 여부는 또한 발전소 유형별로 생산성 증가율이 어떻게 다른지, 그리고 생산성 변화가 발생한 주요인은 무엇인지를 설명함에 있어서도 상당한 차이를 초래하였기 때문에 이들 내용을 확인하기 위해서도 적절한 방식으로 $CO_2$ 배출량을 반영해 주는 것이 중요하다.

  • PDF

열병합발전을 이용한 집단에너지사업의 온실가스 감축효과 (Effects of District Energy Supply by Combined Heat and Power Plant on Greenhouse Gas Emission Mitigation)

  • 신경아;동종인;강재성;임용훈;김다혜
    • 한국기후변화학회지
    • /
    • 제8권3호
    • /
    • pp.213-220
    • /
    • 2017
  • The purpose of this study is to analyze effects of Greenhouse Gas (GHG) emission reduction in district energy business mainly based on Combined Heat and Power (CHP) plants. Firstly this paper compares the actual carbon intensity of power production between conventional power plants and district energy plants. To allocate the GHG from CHP plants, two of different methods which were Alternative Generation Method and Power Bonus Method, have been investigated. The carbon intensity of power production in district energy plants ($0.43tonCO_2e/MWh$) was relatively lower than conventional gas-fired power plants ($0.52tonCO_2e/MWh$). Secondly we assessed the cost effectiveness of reduction by district energy sector compared to the other means using TIMES model method. We find that GHG marginal abatement cost of 'expand CHP' scenario (-$134/ton$CO_2$) is even below than renewable energy scenario such as photovoltaic power generation ($87/ton$CO_2$). Finally the GHG emission reduction potential was reviewed on the projected GHG emission emitted when the same amount of energy produced in combination of conventional power plants and individual boilers as substitution of district energy. It showed there were 10.1~41.8% of GHG emission reduction potential in district energy compared to the combination of conventional power plants and individual boilers.

부하 임피던스 변화에 따른 6.78MHz 전류모드 D급 전력증폭기 특성 해석 (Performance Analysis of 6.78MHz Current Mode Class D Power Amplifier According to Load Impedance Variation)

  • 고석현;박대길;구경헌
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.166-171
    • /
    • 2019
  • 본 논문은 6.78 MHz무선전력전송 송신기의 전송 효율을 높이고 송수신 코일 간격 변화에도 안정적 특성을 확보하기 위해 전류 모드 클래스 D 전력증폭기를 설계한다. 선형증폭기의 이론적인 효율을 제한하는 트랜지스터의 기생 커패시터 성분에 의한 손실을 적게 만들어 전력증폭기의 효율을 향상시킨다. 회로 설계 시뮬레이터를 이용하여 고효율 증폭기를 설계하고 부하 임피던스 변화에 따른 전력 출력, 효율 특성을 시뮬레이션하여 검증하였다. 시뮬레이션에서 DC 바이어스 30 V일 때 42.1 dBm의 출력과 95%의 효율을 갖도록 설계하였다. 전력증폭기를 제작하여 42.1 dBm (16 W)의 출력에서 91%의 효율을 보였다. 드론 무선전력전송에 적용될 송수신 코일을 제작하였으며, 송수신 코일 간격에 따른 부하변화에 따라 전력부가효율이 최대 88% 이고 출력전력 $42.1dBm{\pm}1.7dB$의 특성을 나타내었다.

Coordination Control of Voltage Between STATCOM and Reactive Power Compensation Devices in Steady-State

  • Park, Ji-Ho;Baek, Young-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.689-697
    • /
    • 2012
  • This paper proposes a new coordinated voltage control scheme between STATCOM (Static Synchronous Compensator) and reactive power compensation devices, such as shunt elements(shunt capacitor and shunt reactor) and ULTC(Under-Load Tap Changer) transformer in a local substation. If STATCOM and reactive power compensators are cooperatively used with well designed control algorithm, the target of the voltage control can be achieved in a suddenly changed power system. Also, keeping reactive power reserve in a STATCOM during steady-state operation is always needed to provide reactive power requirements during emergencies. This paper describes the coordinative voltage control method to keep or control the voltage of power system in an allowable range of steady-state and securing method of momentary reactive power reserve using PSS/E with Python. In the proposed method of this paper, the voltage reference of STATCOM is adjusted to keep the voltage of the most sensitive bus to the change of loads and other reactive power compensators also are settled to supply the reactive power shortage in out range of STATCOM to cope with the change of loads. As the result of simulation, it is possible to keep the load bus voltage in limited range and secure the momentary reactive power reserve in spite of broad load range condition.

발전소 주증기 배관 소음 발생 원인 규명 (Identification of Noise Source from Main Steam Line in Power Plant)

  • 손석만;이준신;이선기;이욱륜;이상국
    • 동력기계공학회지
    • /
    • 제7권3호
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

필터뱅크와 적응필터를 이용한 전력품질 외란 검출기법 (Power Quality Disturbances Detection Technique using Filter Bank and Adaptive Filters)

  • 윤재준;이정규;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.162-167
    • /
    • 2012
  • In power quality monitoring, it is very important to detect disturbances (sag, swell, transient, and interruption) accurately. In this paper, a detection method for power quality disturbances by combining the filter bank system and adaptive filter is proposed. To decompose power signal, binary tree structured filter bank system is designed. In the filter bank system, the fundamental filter bank(QMF bank) is used as a module in each decomposing level. An adaptive filter is used to improve the detection accuracy of disturbances for each subband signal. In the adaptive filter, the measure of estimated error change is used to detect singular points of power quality disturbances. Computer simulations were performed on synthetic signals which have disturbances to assess the performance of the proposed method.

결정질 실리콘 태양전지모듈의 최대 출력특성 변화에 영향을 미치는 환경요인 (The Analysis of Environmental Effects on Maximum Output Power Change of Crystalline Silicon Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.12-13
    • /
    • 2007
  • In this paper, we studied the analysis of environmental effects on maximum output power change of crystalline silicon photovoltaic module. During the test period, there was a 5% reduction of maximum output power on an average. And the degree of output power uniformity became better compared to initial value. Using climate data like rain, snow and dust, we tried to find the reasons for maximum power fluctuation. The surface of PV module was monitored using microscope and infrared camera to study temperature distribution. The further analysis is described in the following paper.

  • PDF

가시광 다이오드 레이저의 스펙트럼 및 주입-잠금 특성분석 (Characteristics of Visible Laser Diode and Its Injection-Locking)

  • 남병호;박기수;권진혁
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.278-285
    • /
    • 1994
  • 가시광 디이오드 레이저의 온도와 주입 전류에 따른 발진 스펙트럼의 특성을 분석하고 주입-잠금 실험을 수행하여 잠금 특성을 분석하였다. 다이오드 레이저의 온도와 주입전류에 따른 스펙트럼 분석 결과 모드 도약이 일어나는 것을 관찰할 수 있었으며 모드 도약이 일어나지 않는 영역에서의 온도와 주입 전류의 변화에 대한 주파수 변화율이 각각 약 $33 GHz/^{\circ}C$, 6.6 GHz/mA로 나타남을 알 수 있었다. 일반적인 근적외선 AlGaAs 다이오드 레이저에서 순간적인 모드 도약이 일어나는 것과는 달리 가시광 다이오드 레이저는 모드 도약의 영역이 넓고 다중 모드로 동작하여 불량한 스펙트럼을 나타냈다. 이러한 특성을 갖는 다이오드 레이저를 이용한 주입-잠금 실험 결과 주입 강도가 $0~25\muW$에 대하여 잠금 대역폭은 0~5 GHz로 나타남을 알 수 있었다. 또한 주입 강도를 약 $25\muW$로 고정시키고, 편광 방향을 회전시키며 주입-잠금 대역폭을 측정한 결과 편광 방향에 의존함을 알 수 있었다. 주입-잠금된 광파의 위상 변화를 측정하기 위하여 주 레이저와 종 레이저를 간섭시켜 종 레이저의 주입 전류의 변화에 대한 간섭 무늬의 이동으로 위상의 변화를 조사하였다.

  • PDF