• 제목/요약/키워드: power cable

검색결과 1,555건 처리시간 0.03초

고낙차 조건에서의 154kV XLPE CABLE 설치 (An Installation of 154kV XLPE CABLE in Steep Slope Condition)

  • 황순철;이창수;이천구;고창성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.775-778
    • /
    • 1992
  • In 1980, 154kV OF cable was installed at the Cheong-Pyeong pumped-storage power station. Effective head of this pumped-storage station is 250m between upper and lower re-servior and length of cable route is 750m. However, several failures have happened owing to steep slope during the operation. 154 kV XLPE cable was applied for this power station to eliminate a lack of stability on account of steep slope and successfully installed in 1991. Meanwhile, installation procedure brings about many problem to be solved. In this paper, we describe the counter measure of cable sliding phenomena caused by heat shrinkage as well as the method of installation of cable under the steep slope condition. And hereafter, we think this paper will be a good reference to design and installation of 154kV XLPE cables in steep slope turnnel at urban areas.

  • PDF

고온초전도 케이블의 과도상태 특성 연구 (Study of Transient Characteristics of High Temperature Superconducting Cable)

  • 장현만;이창영;김춘동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.697-699
    • /
    • 2005
  • High temperature superconducting (HTS) cable could be regarded as one of the most promising technologies for large electric power delivery with high reliability and low losses of power transmission system. Therefore, since 2001, LS Cable Ltd. has been developing 22.9kV, 50MVA HTS cable system as a member of DAPAS (Dream for Advanced rower system by Applied Superconductivity technology) program. In 2003, 22.9kV HTS cable system, single-core cable employing BSCCO HTS wires was firstly manufactured in 2003, and then three-core cable was also successfully developed through the demonstration of its field applicability. In this paper, based on these experiences, the relevant design technology and transient characteristics of HTS cable is described.

  • PDF

초고압 고내력 케이블 국내 최초 현장 적용 (First Installation of High Stress EHV XLPE Cable in korea)

  • 오종옥;조성훈;이상교;김한중;오동수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

전력케이블 시스템의 진단기술 지도 (Technical Map of Diagnosis for Power Cable Systems)

  • 김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.4-6
    • /
    • 2005
  • This paper deals with the technical map of diagnosis for power cable systems. For this purpose, failure status, failure and degradation causes, and newly suggested diagnostic techniques were investigated and analyzed. From the analysis, the technical map of diagnosis for power cable systems was proposed.

  • PDF

Impact of cable sag on the efficiency of an inertial mass damper in controlling stay cable vibrations

  • Wang, Zhi-hao;Gao, Hui;Xu, Yan-wei;Chen, Zheng-qing;Wang, Hao
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.83-94
    • /
    • 2019
  • Passive negative stiffness dampers (NSDs) that possess superior energy dissipation abilities, have been proved to be more efficient than commonly adopted passive viscous dampers in controlling stay cable vibrations. Recently, inertial mass dampers (IMDs) have attracted extensive attentions since their properties are similar to NSDs. It has been theoretically predicted that superior supplemental damping can be generated for a taut cable with an IMD. This paper aims to theoretically investigate the impact of the cable sag on the efficiency of an IMD in controlling stay cable vibrations, and experimentally validate superior vibration mitigation performance of the IMD. Both the numerical and asymptotic solutions were obtained for an inclined sag cable with an IMD installed close to the cable end. Based on the asymptotic solution, the cable attainable maximum modal damping ratio and the corresponding optimal damping coefficient of the IMD were derived for a given inertial mass. An electromagnetic IMD (EIMD) with adjustable inertial mass was developed to investigate the effects of inertial mass and cable sag on the vibration mitigation performance of two model cables with different sags through series of first modal free vibration tests. The results show that the sag generally reduces the attainable first modal damping ratio of the cable with a passive viscous damper, while tends to increase the cable maximum attainable modal damping ratio provided by the IMD. The cable sag also decreases the optimum damping coefficient of the IMD when the inertial mass is less than its optimal value. The theoretically predicted first modal damping ratio of the cable with an IMD, taking into account the sag generally, agrees well with that identified from experimental results, while it will be significantly overestimated with a taut-cable model, especially for the cable with large sag.

초전도 케이블의 Quench 특성에 대한 계통안전성 제어방식 (Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable)

  • 이근준;황시돌
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.29-35
    • /
    • 2005
  • 본 논문은 고온 초전도 케이블을 전력계통의 송전용량 증대를 위해 적용시켰을 경우, 고장발생시 초전도케이블에서 예상되는 ??????치의 영향에 대해 안전하게 제어할 수 있는 방법을 제시하였다. 접근 방법으로는 초전도케이블의 ??????치 특성을 열평형 방정식으로 모델링하고 그 결과 고장전류에 따른 케이블의 설계 최대 온도상승한계에 도달하는 시간을 산출하여 기존의 보호계전시스템의 차단시간과 비교함으로서 안전성 여부를 판정하였다. ??????치발생 고장시간을 모의하기 위해 초전도케이블용 EMTDC모형을 개발하였으며, 모의 결과 초전도 케이블 계통을 보호할 수 있는 안전성 제어방식이 설계 가능함을 보였다.

XLPE의 열처리에 의한 결정화도, 가교부산물의 확산에 따른 교류파괴전압 특성 (AC Breakdown Strength According to Crystallinity and Diffusion of Crosslink By-products by Annealing of XLPE)

  • 김영호;이상진;이승엽;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1608-1610
    • /
    • 2000
  • In this work, the effect of annealing on physical and electrical properties of XLPE cable insulation was investigated. One sample was non-annealed and the other two samples were treated under air circulated oven at 80$^{\circ}C$ for five and ten days. In the DSC patterns of annealed specimen, new peaks appeared at near 80$^{\circ}C$ as a proof of thermal history. The degree of crystallinity increased by annealing effect. In the FT-IR spectrums, the change of absorbances to acetophenone and cumyl alcohol were observated according to the radial direction of cable insulation. They slowly diffused into both semi-conductive layer of the cable in proportion to annealing time and lastly led to near equilibrium state through cable insulation. The AC breakdown strength did not increased but the values were stabilized by effects of crystallinity and diffusion of by-products.

  • PDF