• 제목/요약/키워드: power and energy consumption

검색결과 2,012건 처리시간 0.03초

회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석 (Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations)

  • 정현기;김세동
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

종합병원의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정 (Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in General Hospitals)

  • 김세동;신효섭;김수길;오기봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.233-237
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the general hospitals and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 32 general hospitals and 9 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • 제17권3호
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.

가정용 태양광/ESS 통합 스마트 PCS 개발 (Development of Smart PCS(Power Conditioning System) Integrating PV/ESS for Home)

  • 이상학
    • 디지털융복합연구
    • /
    • 제14권7호
    • /
    • pp.193-200
    • /
    • 2016
  • 최근 들어 가정 내 태양광과 에너지저장시스템을 도입하여 에너지 자립도를 높이고자 하는 기술 개발이 활발히 이루어지고 있다. 낮에 생산된 전기를 에너지 저장 시스템에 충전해 두고 전기요금이 높을 때 사용함으로써 효율적인 에너지 관리를 수행할 수 있다. 국내에서는 아직까지 가정용 실시간 요금제가 이루어지고 있지 않지만 누진제 상의 일정 목표까지 전기 사용량을 낮출 수 있다. 가정 내 태양광을 도입하기 위해서는 전력 변환장치인 PCS를 필요로 한다. PCS는 직류로 생산된 전력을 교류로 변환하여 사용하고 에너지 저장 시스템의 충방전을 수행하도록 한다. 에너지 자립형 스마트 홈 시스템은 태양광, 에너지저장시스템에 대한 일반인들의 관심이 높아지면서 해외를 중심으로 시장이 형성되는 단계이다. 본 논문의 결과물은 실환경에 설치되어 검증을 수행하였으며 실시간 요금제를 가정하여 에너지 절감 효과를 분석하였다.

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

UMTS 상태 천이 방식에서 에너지 소비와 활성 지연간의 트레이드오프 성능 분석 (Performance Analysis of Tradeoff between Energy Consumption and Activation Delay in UMTS State Transition Mechanism)

  • 최현호
    • 한국통신학회논문지
    • /
    • 제37A권12호
    • /
    • pp.1085-1092
    • /
    • 2012
  • 이동통신 시스템은 무선 자원과 배터리 전력을 효율적으로 관리하기 위해 사용자 상태 천이 방식을 정의하고 있다. 이러한 상태 천이 방식에서는 에너지 소비가 많은 상태가 기본적으로 짧은 접속 지연을 제공하므로 에너지와 지연 성능 사이에 트레이드오프 관계가 존재한다. 본 논문에서는 이동 응용 서비스의 트래픽 속성을 고려하여 UMTS 시스템의 사용자 상태 천이 방식을 분석한다. 상태 천이 방식의 마르코프 모델링을 통하여 에너지 소비량과 활성 지연을 수학적으로 도출하고 운용 파라미터에 따라 이들의 트레이드오프 관계를 파악한다. 분석 결과로 도출된 에너지-지연 트레이드오프 곡선은 주어진 상태 천이 방식이 달성 가능한 성능 한계를 보여주며 지연 요구사항을 보장하면서 에너지 소비를 최소화하는 최적 운용 전략을 제시한다.

공간정보를 활용한 대도시권역 비상시 에너지 수요량 예측 (Energy Demand Estimation in Metropolitan Area in Case of Emergency using Spatial Information)

  • 남경목;이홍철;이동은
    • 한국건설관리학회논문집
    • /
    • 제20권3호
    • /
    • pp.105-112
    • /
    • 2019
  • 이상고온 현상으로 전력수요가 예측치를 초과하여 대규모 정전사태가 발생하고 있다. 과밀화된 도시의 경우, 예상치 못한 에너지 수급 차질은 막대한 경제적 피해를 초래하고 도시기능을 마비시키는 중요한 위협요소이다. 기존 비상전력 수요량을 추정하는 방법은 도시의 공간적 차원에서 현실적 수요량을 추정할 수 없어 비상시 예비전력 관리가 용이하지 않다. 본 논문은 도시의 공간정보와 건축물 용도별 평상시 에너지소비 원단위, 비상시 전력수요 원단위를 활용하여 비상전력수요의 공간적 분포를 규명하고, 이를 활용하여 비상전력 수요량을 예측하는 방법론을 제시한다.

AC PDP의 무효전력 감소를 위한 CLHS 구동 방법 (CLHS Driving Method for Reducing Reactive Power Consumption in AC PDP)

  • 신재화;김근수
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.577-583
    • /
    • 2011
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration and long gap. However, it is very difficult to apply above technologies because they make many problems such as mis-discharge and high driving voltage. Especially, the reactive power of PDP must be reduced for satisfaction in international standard IEC62087. In this paper, we proposed CLHS driving method which is half sustain driver without energy recovery capacitor. In the experimental results, CLHS driving method reduced reactive power consumption about 10%. Also, CLHS driving method improved the luminance efficiency in all discharge loads. Therefor, the more the discharge load decreases, the more the luminance efficiency improves. When the discharge load is 20%, CLHS driving method improved 5.35%.

대학교 캠퍼스 소형풍력발전기 설치 및 발전량 예측에 관한 연구 (The Prediction of the location and electric Power for Small Wind Powers in the H University Campus)

  • 조관행;윤재옥
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.127-132
    • /
    • 2012
  • The energy consumption in the world is growing rapidly. And the environmental issues of climate become a important task. The interest in renewable energy like wind and solar is increasing now. Especially, by reducing power transmission loss, a small wind power is getting attention at the residential areas and campus of university. In this study, we attempted to estimate and compare the wind energy density using wind data of AWS (Automatic Weather Station) of H University. In this case of a campus, the weibull distribution parameter C is 2.27, and K is 0.88. According to the data, the energy density of the small wind power is 12.7 W/m2. We did CFD(Computational Fluid Dynamics) simulations at H University campus by 7 wind directions(ENE, ESE, SE, NW, WNW, W, WSW). In the results, we suggest 4 small wind powers. The small wind power generating system can produce 4,514kWh annually.

USN에서 에너지 효율성을 고려한 효과적인 클러스터 헤더 선출 알고리즘 (A Energy-Efficient Cluster Header Election Algorithm in Ubiquitous Sensor Networks)

  • 허태성
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권10호
    • /
    • pp.197-203
    • /
    • 2011
  • 유비쿼터스 센서 네트워크(Ubiquitous Sensor Network)는 사람의 접근이 어려운 다양한 환경에 무선 센서들로 구성된 네트워크이다. 그러므로 센서 노드들은 스스로 라우팅 하는 네트워크로 구성되며, 전력(power) 교체가 어렵다는 특징을 가지고 있다. 따라서 전력 소모를 줄이는 다양한 연구가 이루어지고 있다. 일반적으로 클러스터를 이용한 계층적 구조의 라우팅 방식은 평면적 구조의 라우팅 방식에 비해 센서 노드들의 전력소모가 균등하며, 전력 소모가 적어 네트워크의 사용 주기가 길다. 본 논문은 초기 클러스터를 계속 유지하여 클러스터를 구성하는셋업 과정을 초기 한번만 함으로써 센서노드들의 에너지 소모를 줄이도록 하였으며, 다음 라운드의 헤더 선출은 클러스터내의 멤버 노드들 중 에너지가 가장 많은 노드를 선정함으로써 클러스터내의 모든 노드의 에너지 소모를 균등하게 하는 방법을 제안하였다. 이 방식은 클러스터의 모든 노드들의 에너지소모를 줄여 네트워크의 생명주기를 늘리며, 센서들의 에너지 소모를 균등하게 하여 에너지 홀(energy hole) 문제를 개선하고자 하였다. 본 제안방식의 타당성을 모의실험을 통해 확인하였다.