Rack-Level DC Power Solution for Volume Servers

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • v.32 no.6
    • /
    • pp.940-949
    • /
    • 2010
  • Rack-level DC power supply is the optimal technology for providing DC power to a volume server without any power infrastructure changes in an existing AC data center. In this paper, we propose a smartly controllable and monitorable DC rack power system. The proposed system improves power efficiency by changing the power distribution architecture of a conventional method in the rack. We developed an optimal power control method in multipower modules to provide high efficiency at low loads. In addition, the proposed system provides real-time web monitoring of the rack power and environment around a rack. In our experiments, the proposed system improved the power efficiency by over 10% compared to an AC power system providing N+1 redundant power and power monitoring.

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

A Study on the Compensation of Reactive Power by Power MOSFET INVERTER (전력용 MOSFET Inverter에 의한 무방전력보상에 관한 연구)

  • 이계호;김동필
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.163-170
    • /
    • 1987
  • It is known that reactive component of AC power in the power system gives no energy to outside and cuses enlargiment of power apparatus, voltage fluctuation and unstability of power system. The power conversion system and control system which are composed of power semiconductor devices such as tyristor, transistor, GTO and so on have been appeared as new sources of reactive power. So the cmpensation of reactive power in power semiconductor systems is one of impending problem on the point of energy conservation and inprovement of power factor. This paper treates the fundamental review of the current type power compensation system that compensates the reactive power by MOSFET inverter. This inverter detects not only the reactive power of fundamental wave but also that of all harmoics created in the power semiconductor system and is scheduled to control by sampled value.

  • PDF

Improvement of the Power Flow Convergency Using Switched Shunt Reactive Power Sensitivity (Switched Shunt의 무효전력 민감도를 이용한 조류계산 수렴성 개선)

  • Oh, Sung-Kyun;Yang, Min-Yuk;Kim, Kern-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.355-360
    • /
    • 2012
  • It is difficult to converge power flow for the power system planning data. The main cause of power flow diverse is reactive power imbalance. A active power could be adjust by ELD or merit order but a reactive power couldn't dispatch before power flow analysis. The lack of reactive power of power system is cause a inadequate voltage drop This paper suggest new reactive power dispatch algorithm using switched shunt admittance. This algorithm uses reactive power sensitivity called switch shunt jacobian. When proposed algorithm applies to real system data that couldn't be conversed in PSS/E the power flow analysis is converged.

Low Power SoC Design Trends Using EDA Tools (설계툴을 사용한 저전력 SoC 설계 동향)

  • Park, Nam Jin;Joo, Yu Sang;Na, Jung-Chan
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.2
    • /
    • pp.69-78
    • /
    • 2020
  • Small portable devices such as mobile phones and laptops currently display a trend of high power consumption owing to their characteristics of high speed and multifunctionality. Low-power SoC design is one of the important factors that must be considered to increase portable time at limited battery capacities. Popular low power SoC design techniques include clock gating, multi-threshold voltage, power gating, and multi-voltage design. With a decreasing semiconductor process technology size, leakage power can surpass dynamic power in total power consumption; therefore, appropriate low-power SoC design techniques must be combined to reduce power consumption to meet the power specifications. This study examines several low-power SoC design trends that reduce semiconductor SoC dynamic and static power using EDA tools. Low-power SoC design technology can be a competitive advantage, especially in the IoT and AI edge environments, where power usage is typically limited.

Forecasting of new businesses after restructuring of power industry

  • Koo, Young-Duk;Kim, Eun-Sun;Park, Young-Seo
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.2
    • /
    • pp.116-118
    • /
    • 2004
  • In the power industry after restructuring of Power industry will be appeared on-site type business, power retail sales business, and power wholesales business, power dealing business, customer inclination business & delivery of power facilities. Among them, power trade business, customer inclination business and on-site type business will be rapidly increased and occupied attention. In addition, it is forecasted to advent the broker, provider, market place, power marketer, system operator and generator as a main player. Meanwhile, it needs protection of existing power industry and activation of new energy market for accomplishment of restructuring of power industry.

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method (부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구)

  • Lee B. H.;Kim J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

A New Three Winding Coupled Inductor-Assisted High Frequency Boost Chopper Type DC-DC Power Converter with a High Voltage Conversion Ratio

  • Ahmed Tarek;Nagai Shinichiro;Hiraki Eiji;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.99-103
    • /
    • 2005
  • In this paper, a novel circuit topology of a three-winding coupling inductor-assisting a high-frequency PWM boost chopper type DC-DC power converter with a high boost voltage conversion ratio and low switch voltage stress is proposed for the new energy interfaced DC power conditioner in solar photovoltaic and fuel cell generation systems. The operating principle in a steady state is described by using its equivalent circuits under the practical condition of energy processing of a lossless capacitive snubber. The newly-proposed power MOSFET boost chopper type DC-DC power converter with the three-winding coupled inductor type transformer and a single lossless capacitor snubber is built and tested for an output power of 500W. Utilizing the lower voltage and internal resistance power MOSFET switch in the proposed PWM boost chopper type DC-DC power converter can reduce the conduction losses of the active power switch compared to the conventional model. Therefore, the total actual power conversion efficiency under a condition of the nominal rated output power is estimated to be 81.1 %, which is 3.7% higher than the conventional PWM boost chopper DC power conversion circuit topology.