• Title/Summary/Keyword: powder pattern

Search Result 324, Processing Time 0.03 seconds

Changes in Quality Characteristics of Chopped Garlic with Various Storage Method (저장방법에 따른 다진 마늘의 품질특성 변화)

  • 류현주;최은정;오명숙
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.1
    • /
    • pp.167-180
    • /
    • 2004
  • This study was carried out to investigate quality characteristics of chopped garlic stored at various temperature. Chopped garlic was stored at room temp.($25^{\circ}C$), refrigerator temp.($5^{\circ}C$) and frozen temp. ($-18^{\circ}C$) for 1, 2, 4, 8, 24, 48, 72 hours(room temp.) and 1, 3, 5, 7, 10, 15, 20, 30 days(refrigerator temp. and frozen temp.), respectively. Brown color, Hunter color value, vitamine C contents and flavor patterns by electronic noes of chopped garlic were measured. Fresh chopped garlic was used as control and garlic powder by hot air drying was used for comparisons. Brown color of chopped garlic increased with increasing storage time, and the intensity of that was reduced as following order such as chopped garlic stored at room temp., refrigerator temp. and frozen temp. Brown color of garlic powder was most dark amomg all the samples. The results of Hunter color value was consistent with then of brown color in chopped garlic, whereas those of garlic powder showed relatively low browning. Above results might be caused by the difference of measurement as only surface color was measured in Hunter color value unlike brown color. Vitamine C contents of chopped garlic decreased with increasing storage time, and in particular those stored at room temp. decreased markedly as retention of those stored at room temp. was 60% of control after 1 day storage. Vitamine C retention of chopped garlic stored at refrigerator temp. was 78% of control after 10 day storage and that stored at frozen temp. was 86% of control after 30 day storage. At room temp., flavor pattern by electronic nose showed a difference between chopped garlic stored for 1hour and control, and showed occurrence of off odor after 1 day storage. Flavor pattern of garlic powder by electronic nose showed a mild flavor. Flavor patterns of chopped garlic stored at refrigerator temp. were similiar until 10 day storage, whereas those showed occurrence of volitile components after 15 day storage. Flavor patterns of chopped garlic stored at frozen temp. were similiar after 30 day storage, and especially those after 3 day storage were almost the same as control. Therefore it is desirable to store chopped garlic within 1 day at room temp. and within 10 days at refrigerator temp. And it is most desirable to store chopped garlic at frozen temp. as retention of quality characteristics was superior than other storage temp.

Biosynthesis of Silver Nanoparticles by Phytopathogen Xanthomonas oryzae pv. oryzae Strain BXO8

  • Narayanan, Kannan Badri;Sakthivel, Natarajan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.9
    • /
    • pp.1287-1292
    • /
    • 2013
  • Extracellular biogenic synthesis of silver nanoparticles with various shapes using the rice bacterial blight bacterium Xanthomonas oryzae pv. oryzae BXO8 is reported. The synthesized silver nanoparticles were characterized by UV-Vis spectroscopy, powder X-ray diffractometry (XRD), scanning electron microscopy, energy dispersive X-ray spectrometry, and high-resolution transmission electron microscopy (HR-TEM). Based on the evidence of HR-TEM, the synthesized particles were found to be spherical, with anisotropic structures such as triangles and rods, with an average size of 14.86 nm. The crystalline nature of silver nanoparticles was evident from the bright circular spots in the SAED pattern, clear lattice fringes in the high-resolution TEM images, and peaks in the XRD pattern. The FTIR spectrum showed that biomolecules containing amide and carboxylate groups are involved in the reduction and stabilization of the silver nanoparticles. Using such a biological method for the synthesis of silver nanoparticles is a simple, viable, cost-effective, and environmentally friendly process, which can be used in antimicrobial therapy.

서울지하철 3,4호선 Tunnel 굴착과 진동대책 조사연구(1)

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.2
    • /
    • pp.3-15
    • /
    • 1982
  • The study on prevention measures for vibration and excavation of tunnel for the #3, #4, Seoul Subway. In the Seoul subway tunnel blasting, the drilling pattern and prevention method to seismic vibration are as follows as well as for adaptions of NATM, the supportings of roof and wall holes are arranged with control blasting. 1. The blasting is executed basically using the low velocity explosive such as slurry, Nitrate ammonium explosive, and F-I and F-II explosive for control blasting substituting of existing dynamite. 2. The cut holes are arranged with burn cut pattern and also must be arranged with M/S electrical delay caps substituting of ordinary do]ay caps. 3. Jack leg drills are used in Five Job sites and a jumbo drill in one job site. 4. In performance of safety work and in maintenance of building safety. The drilling length for blasting will not exceed 1.20 meter for round so that the vibration value shall carry below 0.3cm/sec. The harmonizing of better powder, better drilling machine and better technique is only the way of improving tunnelling efficiency and less vibration will help the dereasing of accidence.

  • PDF

Volatile Discrimination of Irradiated and Fumigated White Ginseng Powders at Different Storage Times and Temperatures Using the Electronic Nose

  • Shin, Jung-Ah;Kwon, Joong-Ho;Lee, Ki-Teak
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.3
    • /
    • pp.237-242
    • /
    • 2006
  • The pattern of volatile emissions from white ginseng powders (WGP) that were treated with selected preservatives was investigated during 5-months of storage (at -10 and $25^{\circ}C$) by an electronic nose system equipped with 12 metal-oxide sensors. WGP were treated with gamma radiation at 5 kGy, commercial methyl bromide (MeBr), and phosphine fumigations. Electronic nose differentiated the volatile patterns of the WGP with each different preservative treatment. In addition, each volatile pattern was affected by both storage time (1, 2 and 5 months) and temperature (-10 and $25^{\circ}C$). After 5-months of storage, the least change of volatile patterns was observed from WGP fumigated with phosphine at $-10^{\circ}C$. The result also showed that volatile changes in WGP were much more affected by storage time than by storage temperature.

Characteristics in Size Distributions and Morphologies of Wear Particles Depending on Types of Abrasion Testers

  • Eunji Chae;Seong Ryong Yang;Sung-Seen Choi
    • Elastomers and Composites
    • /
    • v.58 no.2
    • /
    • pp.87-94
    • /
    • 2023
  • Abrasion tests of an SBR compound were conducted using four different types of abrasion testers (cut and chip, Lambourn, DIN, and LAT100). The abrasion test results were analyzed in terms of size distributions and morphologies of the wear particles. Most wear particles were larger than 1000 ㎛. The wear particle size distributions tended to decrease as the particle size decreased. Except for the Lambourn abrasion test, the wear particles smaller than 212 ㎛ were rarely generated by the other three abrasion tests, implying that small wear particles were produced through friction by introducing talc powder. Shapes of the wear particles varied depending on the abrasion testers. The wear particles generated from the Lambourn abrasion tester had stick-like shapes. The cut and chip abrasion test showed a clear abrasion pattern, but the DIN abrasion test did not show any specific abrasion pattern. The Lambourn and LAT100 abrasion tests showed irregular abrasion patterns.

Evaluation of Characteristics for A Liquid Powder e-paper( I ) (액상분말 전자종이 특성평가( I ))

  • Kwon, Ki-Young;Kim, Young-Cho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.51-53
    • /
    • 2007
  • 본 논문에서는 차세대 디스플레이로 각광받고 있는 플렉시블 디스플레이의 일환으로 전하를 갖는 입자가 전계에 의한 운동(Movement)을 기반으로 이미지를 구현하는 유리 기판 기반의 액상분말 전자종이의 패턴(Pattern)을 설계하였으며 셀 캡(Cell Gap)에 따른 구동전압의 변화를 검토하였다. 확보된 데이터를 바탕으로 플렉시블 기판을 적용한 패널을 제작할 경우 효율적인 전기적 특성을 갖는 소자의 설계조건이 제시되었다.

  • PDF

Changes in Extraction Pattern and field of Bamboo Leaf Powder at Different Extraction Conditions (추출조건에 따른 죽엽분말의 추출패턴과 수율변화)

  • 이경은;오남순;박원종;류기형
    • Food Industry And Nutrition
    • /
    • v.9 no.1
    • /
    • pp.46-52
    • /
    • 2004
  • 최근 생활수준의 향상으로 식생활의 서구화와 식품의 제조 및 가공기술의 발달로 장기저장 식품 및 인스턴트식품의 이용도가 현저히 증가하고 있으며 이를 위한 식품첨가물에 대한 관심도 높아지고 있다. 식문화가 바뀌면서 당뇨병, 고혈압, 동맥 경화증 등의 성인병 질환이 급증하고 (1,2) 이러한 만성병의 증가로 식품과 질병과의 연계성에 관한 관심이 급격히 증가하고 있다. 이러한 경향에 따라 식물성 원료의 생리활성 성분에 대한 관심이 높아지고 국내ㆍ외적으로 생리활성 성분을 함유한 신소재 식물들을 원료로 이용하려는 시도가 많이 이루어지고 있다(3,4). (중략)

  • PDF

Thermal Chemical Vapor Deposition법으로 성장된 MoS2 박막의 물리적 특성 분석

  • Chu, Dong-Il;Lee, Dong-Uk;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.376.1-376.1
    • /
    • 2014
  • 그래핀은 차세대 2차원 물질로서 지금까지 활발히 연구되어 왔으나 밴드갭이 없기 때문에 전자소자로서의 응용이 매우 제한적이다. 최근에 그래핀을 대체할 수 있는 물질로서 Transition Metal Dichalcogenides (TMDs)가 주목을 받고 있다. 특히, TMDs 중에서 $MoS_2$는 bulk일 때 indirect한 1.2 eV인 밴드 갭을 갖고 있으나, layer가 줄어들면서 direct한 1.8 eV인 밴드갭을 가진다. 국내외 여러 연구 그룹에서 $MoS_2$를 이용하여 제작한 Field Effect Transistor (FET)는 high-$\small{K}$ gate가 산입되지 않은 경우에 on-off ratio와 mobility가 각각 $10^6$와 약 $3cm^2/Vs$로 나타나고 있다. 이와 같이 아주 우수한 전기적, 광학적 특성을 갖는 소자 응용성을 가지고 있다. 최근까지의 연구결과들은 대부분 mechanical exfoliation method (MEM) 로 제작된 $MoS_2$ monolayer를 이용하였으나, 이 방법은 large scale 및 layer controllable에는 적합하지 않다. 본 연구에서는 대면적의 집적회로 응용에 적합한 chemical vapor deposition법을 이용하여 $MoS_2$를 성장하였다. 높은 결정성을 위해 sulphur (powder purity 99.99%)와 molybdenum trioxide(powder purity 99.9%)를 이용하고, Ar 가스 분위기에서 sulphur powder 및 molybdenum trioxide powder를 각각 $130^{\circ}C$$1000^{\circ}C$로 유지하며 $MoS_2$ 박막을 성장하였다. 성장된 $MoS_2$ 박막은 Atomic force Microscopy (AFM)을 통해 박막의 단차와 roughness을 확인하였다. 또한, X-ray Diffraction (XRD) pattern 분석으로 박막의 결정성을 확인하였으며, Raman Spectroscopy, X-ray Photoelectron Spectroscopy (XPS), Photoluminescence (PL) 측정으로 광학적 특성을 분석하였다.

  • PDF

Blasting Standardization works for NATM on the Seoul Subway Construction by Dr, Ginn Huh (서울 지하철공사 발파공법의 표준화)

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.16 no.3
    • /
    • pp.5-23
    • /
    • 1983
  • On the Seoul Metropolitan Subway Construction of No. 3, 4 Line, the total length is 57 Km and it is now undergoing almost 55% progress. The working method is classified into Open Cut of 70% and the rest of 30% tunnelling method in the 48 job site. Above tunnelling method is execute by American Steel Support System and the rest of 10 job site carried out by New Austria Tunnelling Method. This paper describes Blasting Standardizations works on the above Tunnelling ' Open Cut Method under big slogan, first safety, second execution. As a superintendent, I strived standardization of works with Better powder, Better Drills ' Better Pattern. Geological structure of Seoul area is composed by Jurassic Granite and also the above rockgroup are over burden by Alluviums as a Unconformity. First of all, I carried out the standard amount of powder and burden through experimental standard blasting by each powder as following Blasting works in the subway construction is surrounding shop Building, under pass the city river and also under pass highest building basement floor. I made allowable Blasting Vibration Value by West-Germany Vornorm DIN 4150, Teil 3 and should measure each blasting works as fellows all of powder is used basically Low-Gravity and Low Velocity such as Slurry, Ammonium Nitrate ' Finex I, II. for Smooth Blasting Instead of Gelatin Dynamite. Electric Detonation Cap is used basically M/S Delay Cup instead of Electric delay ' Simultaneous cap. I applied following formula V=KW3/4 $D^{-2}$ V=Particle Velocity (Cm/sec) K=Ginh Huh's Value W=Delay Charge (Kg) D=Distance(m) In the Open Cut, within 1m distance from H-pile I made to use the Concrete breaker, as following V=7W/$^{0.5}$V/$^{-1.75}$ On the Concentrate Building area, I advise to use Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.e Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.

  • PDF

The Production of Functional Peptide from Whey Using Immobilized Trypsin (유청으로부터 고정화 트립신을 이용한 기능성 펩타이드의 생산)

  • Park, Yun-Joo;Yun, Yeo-Pyo;Lee, Hyung-Joo;Jang, Hae-Dong
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.99-104
    • /
    • 1996
  • Carbohydrate-free caseinomacropeptide (CMP) was isolated from the sweet whey powder by a precipitation method using 12% trichloroacetic acid. The yield of carbohydrate-free CMP was 2.7 g from 100 g sweet whey powder. The electrophoretic pattern and the amino acid analysis of CMP showed that isolated CMP was quite pure, indicating the precipitation with 12% trichloroacetic acid was very effective for isolating carbohydrate-free CMP from the sweet whey powder. Trypsin, covalently immobilized on pore glass beads by carbodiimide (EDC) method, was 20mg per 1g glass beads. CMP was almost completely hydrolyzed by soluble trypsin in 24hr, but not by immobilized trypsin. The tryptic hydrolysates were fractionated on a Bio-Gel P 4 column $(1.5{\times}120\;cm)$and separated peptides were tested for their capacities to inhibit platelet aggregation using a aggregometer. The hydrolysate obtained from CMP after 24hr digestion by immobilized trypsin showed the highest activity.

  • PDF