• Title/Summary/Keyword: potential radiation dose

Search Result 196, Processing Time 0.029 seconds

Prediction of Late Rectal Complication Following High-dose-rate Intracavitary Brachytherapy in Cancer of the Uterine Cervix (자궁경부암 환자의 고선량률 강내치료 시행 시 직장합병증의 예측)

  • Lee, Jeung-Eun;Huh, Seung-Jae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.276-282
    • /
    • 2003
  • Purpose: Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. Materials and Methods: A retrospective analysis was peformed for 222 patients with cevix cancer who were treated for curative intent with external beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6$\~$56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3$\~$5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. in vivo measurement of the rectal dose was peformed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Results: Twenty-one patients (9.5$\%$) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70$\%$, or when the measured rectal BED was over 110 Gy$_{3}$, a high possibility of late rectal complication was found. Conclusion: Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using TLD during HDR ICR. If data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

Carbon Ion Therapy: A Review of an Advanced Technology

  • Kim, Jung-in;Park, Jong Min;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.71-80
    • /
    • 2020
  • This paper provides a brief review of the advanced technologies for carbon ion radiotherapy (CIRT), with a focus on current developments. Compared to photon beam therapy, treatment using heavy ions, especially a carbon beam, has potential advantages due to its physical and biological properties. Carbon ion beams with high linear energy transfer demonstrate high relative biological effectiveness in cell killing, particularly at the Bragg peak. With these unique properties, CIRT allows for accurate targeting and dose escalation for tumors with better sparing of adjacent normal tissues. Recently, the available CIRT technologies included fast pencil beam scanning, superconducting rotating gantry, respiratory motion management, and accurate beam modeling for the treatment planning system. These techniques provide precise treatment, operational efficiency, and patient comfort. Currently, there are 12 CIRT facilities worldwide; with technological improvements, they continue to grow in number. Ongoing technological developments include the use of multiple ion beams, effective beam delivery, accurate biological modeling, and downsizing the facility.

The potential of X-ray irradiation as a new pasteurization technology for food (식품 살균을 위한 X선 조사 기술의 활용 및 전망)

  • Lim, Jong-Seong;Ha, Jae-Won
    • Food Science and Industry
    • /
    • v.53 no.3
    • /
    • pp.264-276
    • /
    • 2020
  • Ionizing radiation is one of the efficient non-thermal pasteurization methods. The US Food and Drug Administration (FDA) allows the use of ionizing radiation to a dose up to 10 kGy for controlling foodborne pathogens and extending the self-life of foods. Recently X-rays, generated on absorption of high energy electrons in an appropriate metal target, have been used commercially for sterilization purposes. X-rays have the advantages of higher penetration power than E-beams and absence of harmful radioactive sources, such as Cobalt-60 or Cesium-137 associated with gamma-rays. That is why it has continued to receive attention as an attractive alternative to gamma-ray or E-beam irradiation. In this article, the potential of X-ray irradiation for controlling foodborne pathogens in various food products and necessary pre-requisite knowledge for the introduction of X-ray irradiation to the Korean food industry will be provided.

A Result and Prognostic Factors of Hypofractionation Radiation Therapy in Early Glottic Cancer (초기 성문암 환자에서 소분할조사법의 방사선 치료 결과와 예후 인자)

  • Lee Mi-Jo;Kim Hun-Jung;Kim Woo-Chul;Loh Jun-Gou
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.2
    • /
    • pp.132-138
    • /
    • 2005
  • Purpose: The purpose of this study was to establish general guidelines for the treatment of patients with early glottic cancer(T1-2N0M0), by assessing the role of primary radiation therapy and by analyzing the tumor-related and treatment-related factors that influence treatment results. We also studied the results of hypofractionated radiation therapy for early glottic cancer. Material and Methods: This retrospective study comprised 48 patients who suffered from early glottic cancer and were treated by primary radiotherapy at Inha University Hospital, between May 1997 and October 2004. T-stage distribution showed 38 patients as T1 and 10 patients as stage T2. Thirty-eight patients underwent hypofractionated radiotherapy using a 6 MY photon beam, a total tumor dose of 63Gy, in 5 weekly fractions of 2.25Gy, with an overall radiation treatment time of 38 days. Ten patients in the T2 stage tolerated a total dose of 63-72 Gy(median 68.4Gy) in 5 weekly fractions of 1.8-2.0Gy, with an overall radiation treatment time of 40-87 days(median 51 days). All patients were followed up for at least 3 years. Univariate and multivariate analyses were performed to identify the prognostic factors affecting the treatment results. Result: The 5-year survival rate was 92% for all patients, 94% for T1 patients and 91% for T2 patients. The local control rate was 93.5% for all patients, 95% for T1 and 92.2% for T2 patients. Three patients suffered a relapse following radiotherapy, and underwent subsequent salvage surgery. We included T-stage, tumor location, total radiation dose, field size and overall radiation treatment time as potential prognostic factors. Only T-stage was found to be statistically significant in the univariate analysis, but in the multivariate analysis, it was not found to be significant. Conclusion: High curative and voice preservation rates were obtained with hypofractionated radiotherapy. Further study with a larger number of patients is needed to determine the prognostic factors affecting treatment results.

The Tumor Control According to Radiation Dose of Gamma Knife Radiosurgery for Small and Medium-Sized Brain Metastases from Non-Small Cell Lung Cancer

  • Park, Sue Jee;Lim, Sa-Hoe;Kim, Young-Jin;Moon, Kyung-Sub;Kim, In-Young;Jung, Shin;Kim, Seul-Kee;Oh, In-Jae;Hong, Jong-Hwan;Jung, Tae-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.983-994
    • /
    • 2021
  • Objective : The effectiveness of gamma knife radiosurgery (GKR) in the treatment of brain metastases is well established. The aim of this study was to evaluate the efficacy and safety of maximizing the radiation dose in GKR and the factors influencing tumor control in cases of small and medium-sized brain metastases from non-small cell lung cancer (NSCLC). Methods : We analyzed 230 metastatic brain tumors less than 5 mL in volume in 146 patients with NSCLC who underwent GKR. The patients had no previous radiation therapy for brain metastases. The pathologies of the tumors were adenocarcinoma (n=207), squamous cell carcinoma (n=18), and others (n=5). The radiation doses were classified as 18, 20, 22, and 24 Gy, and based on the tumor volume, the tumors were categorized as follows : small-sized (less than 1 mL) and medium-sized (1-3 and 3-5 mL). The progression-free survival (PFS) of the individual 230 tumors and 146 brain metastases was evaluated after GKR depending on the pathology, Eastern Cooperative Oncology Group (ECOG) performance score (PS), tumor volume, radiation dose, and anti-cancer regimens. The radiotoxicity after GKR was also evaluated. Results : After GKR, the restricted mean PFS of individual 230 tumors at 24 months was 15.6 months (14.0-17.1). In small-sized tumors, as the dose of radiation increased, the tumor control rates tended to increase (p=0.072). In medium-sized tumors, there was no statistically difference in PFS with an increase of radiation dose (p=0.783). On univariate analyses, a statistically significant increase in PFS was associated with adenocarcinomas (p=0.001), tumors with ECOG PS 0 (p=0.005), small-sized tumors (p=0.003), radiation dose of 24 Gy (p=0.014), synchronous lesions (p=0.002), and targeted therapy (p=0.004). On multivariate analyses, an improved PFS was seen with targeted therapy (hazard ratio, 0.356; 95% confidence interval, 0.150-0.842; p=0.019). After GKR, the restricted mean PFS of brain at 24 months was 9.8 months (8.5-11.1) in 146 patients, and the pattern of recurrence was mostly distant within the brain (66.4%). The small and medium-sized tumors treated with GKR showed radiotoxicitiy in five out of 230 tumors (2.2%), which were controlled with medical treatment. Conclusion : The small-sized tumors were effectively controlled without symptomatic radiation necrosis as the radiation dose was increased up to 24 Gy. The medium-sized tumors showed potential for symptomatic radiation necrosis without signifcant tumor control rate, when greater than 18 Gy. GKR combined targeted therapy improved the tumor control of GKR-treated tumors.

Assessment of Radiological Hazards in Some Foods Products Consumed by the Malian Population Using Gamma Spectrometry

  • Adama Coulibaly;David O. Kpeglo;Emmanuel O. Darko
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.84-89
    • /
    • 2023
  • Background: Food consumption is one of the most important routes for radionuclide intake for the public; therefore, there is the need to have a comprehensive understanding of the amount of radioactivity in food products. Consumption of radionuclide-contaminated food could increase potential health risks associated with exposure to radiation such as cancers. The present study aims to determine radioactivity levels in some food products (milk, rice, sugar, and wheat flour) consumed in Mali and to evaluate the radiological effect on the public health from these radionuclides. Materials and Methods: The health impact due to ingestion of radionuclides from these foods was evaluated by the determination of activity concentration of radionuclides 238U, 232Th, 40K, and 137Cs using gamma spectrometry system with high-purity germanium detector and radiological hazards index in 16 samples collected in some markets, mall, and shops of Bamako-Mali. Results and Discussion: The average activity concentrations were 9.8±0.6 Bq/kg for 238U, 8.7±0.5 Bq/kg for 232Th, 162.9±7.9 Bq/kg for 40K, and 0.0035±0.0005 Bq/kg for 137Cs. The mean values of radiological hazard parameters such as annual committed effective dose, internal hazard index, and risk assessment from this work were within the dose criteria limits given by international organizations (International Commission on Radiological Protection and United Nations Scientific Committee on the Effects of Atomic Radiation) and national standards. Conclusion: The results show low public exposure to radioactivity and associated radiological impact on public health. Nevertheless, this study stipulates vital data for future research and regulatory authorities in Mali.

Clinical Application of 3-D Conformal Radiotherapy for Carcinoma of the Ethmoid Sinus : I. Comparative Analysis Between Conventional 2-D and 3-D Conformal Plans (사골동 종양의 3-차원 입체조형치료 : I. 2차원 치료계획과 3차원 치료계획의 비교분석)

  • Lee Sangwook;Kim Gwi Eon;Keum Ki Chang;Park Hee Chul;Cho Jae Ho;Han Soung Uk;Lee Kang Kyu;Suh Chang Ok;Hong Won Pyo;Park In Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.287-296
    • /
    • 1997
  • Purpose : This is study of whether 3-D conformal radiotherapy for carcino-mas of the ethmoid sinus were better than those treated with conventional 2-D plan, Materials and Methods : The 3-D conformal treatment Plans were compared with conventional 2-D plans in 4 patients with malignancy of the ethmoid sinus. Isodose distribution, dose statistics, and dose volume histogram of the planning target volume were used to evaluate differences between 2-D and 3-D plans. In addition. the risk of radiation exposure of surrounding normal critical organs are evaluated by means of point dose calculation and dose volume histogram. Results : 3-D conformal treatment plans for each patient that the better tumor coverages by the planning target volume with improved dose homo-geneity, compared to 2-D conventional treatment Plans in the same Patient. On the other hand, the radiation dose distributions to the surrounding nor-mal tissue organs, such as the orbit and optic nerves are not significantly reduced with our technique, but a substantial sparing in the brain stem and optic chiasm for each patient. Conclusion : Our findings represented the potential advantage of 3-D treatment planning for dose homogeniety as well as sparing of the normal tissue surrounding the tumor. However, further investigational studies are required to define the clinical benefit.

  • PDF

Analysis of Domestic and Overseas Radioactive Waste Maritime Transportation and Dose Assessment for the Public by Sinking Accident (국내·외 방사성폐기물 해상운반 현황 및 침몰사고 시 일반인 선량평가 사례 분석)

  • Ga Eun Oh;Min Woo Kwak;Hyeok Jae Kim;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Demand for RW transportation is expected to increase due to the continuous generation of RW from nuclear power plants and facilities, decommissioning of plants, and saturation of spent fuel temporary storage facilities. The locational aspect of plants and radiation protection optimization for the public have led to an increasing demand for maritime transportation, necessitating to apprehend the overseas and domestic current status. Given the potential long-term radiological impact on the public in the event of a sinking accident, a pre-transportation exposure assessment is necessary. The objective of this study is to investigate the overseas and domestic RW maritime transportation current status and overseas dose assessment cases for the public in sinking accident. Selected countries, including Japan, UK, Sweden, and Korea, were examined for transport cases, Japan and the U.S were chosen for dose assessment case in sinking accidents. As a result of the maritime transportation case analysis, it was performed between nuclear power plants and reprocessing facilities, from plants to disposal or intermediate storage facilities. HLW and MOX fuel were transported using INF 3 shipments, and all transports were performed low speed of 13 kn or less. As a result of the dose assessment for the public in sinking accident, japan conducted an assessment for the sinking of spent fuel and vitrified HLW, and the U.S conducted for the sinking of spent fuel. Both countries considered external exposure through swimming and working at seashore, and internal exposure through seafood ingestion as exposure pathway. Additionally, Japan considered external exposure through working on board and fishing, and the U.S considered internal exposure through spray inhalation and desalinized water and salt ingestion. Internal exposure through seafood ingestion had the largest dose contribution. The average public exposure dose was 20 years after the sinking, 0.04 mSv yr-1 for spent fuel and 5 years after the sinking, 0.03 mSv yr-1 for vitrified HLW in Japan. In the U.S, it was 1.81 mSv yr-1 5 years after the sinking of spent fuel. The results of this study will be used as fundamental data for maritime transportation of domestic RW in the future.

Mineral Phosphate Solubilization by Wild Type and Radiation Induced Mutants of Pantoea dispersa and Pantoea terrae

  • Murugesan, Senthilkumar;Lee, Young-Keun;Kim, Jung Hun
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Three mineral phosphate solubilizing (MPS) bacteria where isolated from rhizosphere soil samples of common bean and weed plants. 16S rDNA analysis indicated that the isolate P2 and P3 are closely related to Pantoea dispersa while isolate P4 is closely related to Pantoea terrae. Isolates P2 and P3 recorded $381.60{\mu}g\;ml^{-1}$ and $356.27{\mu}g\;ml^{-1}$ of tricalcium phosphate (TCP) solubilization respectively on 3 days incubation. Isolate P4 recorded the TCP solubilization of $215.85{\mu}g\;ml^{-1}$ and the pH was dropped to 4.44 on 24 h incubation. Further incubation of P4 sharply decreased the available phosphorous to $28.94{\mu}g\;ml^{-1}$ and pH level was raised to 6.32. Gamma radiation induced mutagenesis was carried out at $LD_{99}$ dose of the wild type strains. The total of 14 mutant clones with enhanced MPS activity and 4 clones with decreased activity were selected based on solubilization index (SI) and phosphate solubilization assay. Mutant P2-M1 recorded the highest P-solubilizing potential among any other wild or mutant clones by releasing $504.21{\mu}g\;ml^{-1}$ of phosphorous i.e. 35% higher than its wild type by the end of day 5. A comparative evaluation of TCP solubilization by wild type isolates of Pantoea and their mutants, led to select three MPS mutant clones such as P2-M1, P3-M2 and P3-M4 with a potential to release >$471.67{\mu}g\;ml^{-1}$ of phosphorous from TCP. These over expressing mutant clones are considered as suitable candidates for biofertilization.

A Study on the Evaluation of 3D Dose Distribution using Normoxic Polymer Gel (정상산소 중합체 겔 선량계를 이용한 3차원 방사선량 평가에 관한 연구)

  • Chung, Se-Young;Kim, Young-Bum;Kwon, Young-Ho;Lee, Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2007
  • Purpose: As increasing complexity of modern radiotherapy technique, more developing dosimetry is required. Polymer gel dosimeters offer a wide range of potential applications with high resolution and assured quality in the thee-dimensional verification of complex dose distribution such as intensity-modulated radiotherapy (IMRT). The purpose of this study is to find the most sensitive and suitable gel as a dosimeter by varying its composition ratio and its condition such as temperature during manufacturing. Materials and Methods: Each polymer gel with various ratio of composition was irradiated with the same amount of photon beam accordingly. Various polymer gels were analyzed and compared using a dedicated software written in visual C++ which converts TE images to R2 map images. Their sensitivities to the photon beam depending on their composition ratio were investigated. Results: There is no dependence on beam energy nor dose rate, and calibration curve is linear. Conclusion: The polymer gel dosimeter developed by using anti-oxidant in this study proved to be suitable for dosimetry.

  • PDF