• Title/Summary/Keyword: potential error

Search Result 711, Processing Time 0.032 seconds

Comparing Surplus Production Models for Selecting Effective Stock Assessment Model: Analyzing Potential Yield of East Sea, Republic of Korea (효과적인 자원평가모델 선정을 위한 잉여생산량모델의 비교 분석: 동해 생태계의 잠재생산량 분석을 대상으로)

  • Choi, Min-Je;Kim, Do-Hoon
    • Ocean and Polar Research
    • /
    • v.41 no.3
    • /
    • pp.183-191
    • /
    • 2019
  • This study sought to find which model is most appropriate for estimating potential yield in the East Sea, Republic of Korea. For comparison purposes, the Process-error model, ASPIC model, Maximum entropy model, Observation-error model, and Bayesian state-space model were applied using data from catch amounts and total efforts of the whole catchable fishes in the East Sea. Results showed that the Bayesian state-space model was estimated to be the most reliable among the models. Potential yield of catchable species was estimated to be 227,858 tons per year. In addition, it was analyzed that the amount of fishery resources in 2016 was about 63% of the biomass that enables a fish stock to deliver the maximum sustainable yield.

Effects of Illuminating Condition on ERP and Work Performance during a Counting Task (계수작업시 사상관련전위 및 작업성능에 미치는 조명조건의 영향)

  • 임현교
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.167-175
    • /
    • 2000
  • Work performance and human error are complicated phenomena so that it is very difficult to grasp the true nature of them. However, Event Related Potential (ERP) may give a clue to them because human brain reflects diverse psychophysiological process. In the present study, the possibility of ERP application to the ergonomic area was evaluated in view of grasping error symptoms. For that purpose, the subjects were asked to count specific characters in a random character matrix on a computer monitor, and their ERP was compared with their performance data. Based upon the results, the amplitude of P300 was not so high as that in the case of the Odd Ball tasks, correct response corresponded with stable ERP with high P300 amplitude whereas wrong response did with unstable, fluctuating ERP with low P300 amplitude. Those results coincided with the work performance, and it was concluded that 3-wave fluorescent with illumination level of 800 lux would be recommendable for the counting task in concern. Conclusively, ERP including P300 might supply an objective clue to the problem of human errors in cognitive process.

  • PDF

Characteristics for Ground Impedance of Counterpoise according to Position of Auxiliary Probe and Frequency (보조전극의 배치 및 주파수에 따른 매설지선의 접지임피던스 특성)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.33-37
    • /
    • 2012
  • This paper describes the characteristics for ground impedance of counterpoise according to position of auxiliary probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 10[m] to 100[m] and the measuring frequency was ranged in 55 [Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of auxiliary probe when the ground impedance was measured at grounding system.

The Path Plan for Slip Reduction of Mobile Robot and Slip Compansation Method (이동 로봇의 슬립 감소를 위한 이동 경로 계획 및 슬립 보상방식)

  • Eom, Ki-Hwan;Kang, Seong-Ho;Jung, Kyung-Kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.785-796
    • /
    • 2009
  • In this paper, propose for mobile robot path planning and the reduction in sleep caused by a sleep history suggested a way to compensate for record sensor error. The proposed path plan reduces the robot slip to smooth a potential barrier in the potential field method, and compensates the tachometer error by robot slip using the fuzzy logic system. The efficiency of the proposed method is verified by means of simulations and experiments for path plan and slip revision.

Microbial BOD Sensor Using Hansenula anomala

  • Ihn Gwon-Shik;Park Kyung-Ho;Pek Un-Hua;Sohn Moo-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.145-148
    • /
    • 1992
  • A microbial sensor for BOD (Biochemical Oxygen Demand) measurement has been developed by immobilizing Hansenula anomala in a polyacrylamide gel. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $30^{\circ}C$, respectively. The response time was 30 min. A linear relationship was observed between the potential and the concentration below 44 ppm BOD. The potential was reproducible within ${\pm}9%$ of the relative error when a sample solution containing 20 mg/l of glucose and 20 mg/l of glutamic acid was employed. The effect of various compounds on BOD estimation was also examined. The potential output of the sensor was almost constant for 30 days. The relative error in BOD estimation was within ${\pm}10%$.

Comparative analysis of stock assessment models for analyzing potential yield of fishery resources in the West Sea, Korea (서해 어획대상 잠재생산량 추정을 위한 자원평가모델의 비교 분석)

  • CHOI, Min-Je;KIM, Do-Hoon;CHOI, Ji-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.3
    • /
    • pp.206-216
    • /
    • 2019
  • This study is aimed to compare stock assessment models depending on how the models fit to observed data. Process-error model, Observation-error model, and Bayesian state-space model for the Korean Western coast fisheries were applied for comparison. Analytical results show that there is the least error between the estimated CPUE and the observed CPUE with the Bayesian state-space model; consequently, results of the Bayesian state-space model are the most reliable. According to the Bayesian State-space model, potential yield of fishery resources in the West Sea of Korea is estimated to be 231,949 tons per year. However, the results show that the fishery resources of West Sea have been decreasing since 1967. In addition, the amounts of stock in 2013 are assessed to be only 36% of the stock biomass at MSY level. Therefore, policy efforts are needed to recover the fishery resources of West Sea of Korea.

Analysis of Optical Transfer Function and Phase Error of the Modified Triangular Interferometer

  • Kim, Soo-Gil;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.10-18
    • /
    • 2007
  • We synthesize and analyze the optical transfer function(OTF) of the modified triangular interferometer(MTI) using two-pupil synthesis method and we present the optimal MTI, which can obtain any bipolar function by combining a wave plate and a linear polarizer. Also, we analyze its potential phase error sources caused by polarization components.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

Evaluation of Inverse Fourier Integral Considering the Distances from the Source Point in 2D Resistivity Modeling (전기비저항탐사 2차원 모델링에서 송수신 간격을 고려한 푸리에 역변환)

  • Cho, In-Ky;Jeong, Da-Bhin
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • In the two-dimensional (2D) modeling of electrical method, the potential in the space domain is reconstructed with the calculated potentials in the wavenumber domain using inverse Fourier transform. The inverse Fourier integral is numerically evaluated using the transformed potential at different wavenumbers. In order to improve the precision of the integration, either the logarithmic or exponential approximation has been used depending on the size of wavenumber. Two numerical methods have been generally used to evaluate the integral; interval integration and Gaussian quadrature. However, both methods do not consider the distance from the current source. Thus the resulting potential in the space domain shows some error. Especially when the distance from the current source is very small or large, the error increases abruptly and the evaluated potential becomes extremely unstable. In this study, we developed a new method to calculate the integral accurately by introducing the distance from the current source to the rescaled Gauss abscissa and weight. The numerical tests for homogeneous half-space model show that the developed method can yield the error level lower than 0.4 percent over the various distances from the current source.