Enhanced ion-exchange properties of clinoptilolite to reduce the leaching of nitrate in soil

  • Kabuba, John
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.41-52
    • /
    • 2022
  • The leaching of nitrate from soil increases the concentration of elements, such as nitrogen, phosphorus, and potassium, in water, causing eutrophication. In this study, the feasibility of using clinoptilolite as an ion-exchange material to reduce nitrate leaching in soil was investigated. Soil samples were collected from three soil depths (0 - 30, 30 - 90, and 90 - 120 cm), and their sorption capacity was determined using batch experiments. The effects of contact time, initial concentration, adsorbent dosage, pH, and temperature on the removal of NO3- were investigated. The results showed that an initial concentration of 25 mg L-1, a contact time of 120 min, an adsorbent dosage of 5.0 g/100 mL, a pH of 3, and a temperature of 30 ℃ are favorable conditions. The kinetic results corresponded well with a pseudo-second-order rate equation. Intra-particle diffusion also played a significant role in the initial stage of the adsorption process. Thermodynamic studies revealed that the adsorption process is spontaneous, random, and endothermic. The results suggest that a modification of clinoptilolite effectively reduces the leaching of nitrate in soil.

수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발 (Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients)

  • 김기영;이상봉;장영창
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

스크린 프린팅 기반 저가형의 플렉서블 칼륨 이온 센서 제조 및 이의 전기화학적 특성 (Fabrication of Low-cost and Flexible Potassium Ion Sensors based on Screen Printing and Their Electrochemical Characteristics)

  • 손선규;박홍준;김영균;조현상;최봉길
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.737-741
    • /
    • 2019
  • 본 연구에서는 스크린 프린팅 공정을 이용하여 저렴하고 유연한 칼륨 이온(K+) 센서를 제작하였다. 전도성 잉크의 균일한 코팅은 주사 전자 현미경 및 광학 현미경 측정에 의해 입증되었다. K+ 센서는 높은 감도, 빠른 응답 시간, 낮은 검출 한계를 보여주었다. 제조된 K+ 센서의 감도는 기계적으로 구부러진 상태에도 여전히 유지되었다. 히스테리시스 효과가 없는 우수한 반복성과 우수한 장기 안정성이 K+ 센서의 전기화학적 특성 분석에서 관찰되었다. 또한, K+ 센서는 다른 간섭 양이온이 존재하는 경우에도 정확하게 K+ 농도를 측정 할 수 있어 우수한 선택성을 증명하였다. 또한, 실제 스포츠 음료 샘플에서 K+ 농도의 성공적인 측정은 K+ 센서의 K+ 농도 값과 상용 K+ 미터를 비교하여 증명되었다.

자라 심장 박출량과 $K^{+}$ 농도 (Effects of Potassium Ion Concentrations on the Cardiac Performances in the Turtle Heart Amyda japonica)

  • 김전;남기용
    • The Korean Journal of Physiology
    • /
    • 제14권1호
    • /
    • pp.31-39
    • /
    • 1980
  • Changes in cardiac performances were observed under variations of the arterial and/or venous pressures with K-loading or K-depletion in turtle heart. Hearts were perfused with turtle Ringer-Locke's solutions containing various levels of potassium ion concentration. When venous pressure increased from 4 to 12 cm $H_2O$, cardiac output increased from $6.2{\pm}0.68$ to $15.7{\pm}0.75\;ml/min$, concomittantly. On the contrary, cardiac output decreased during the elevation of arterial pressure. Stroke work increased more prominently during the arterial pressure elevation than during the elevation of venous pressure. During K-depletion$(1{\sim}2mEq/L)$, cardiac output increased to two times that of normal K-concentration$(3{\sim}6\;mEq/L)$ group. Heart rate increased also, but less markedly. In K-loaded$(7{\sim}8\;mEq/L)$ group, both the cardiac output and heart rate decreased but stroke volume rather increased, because heart rate decrement was disproportionate to that of cardiac output. We concluded that in perfused turtle heart, cardiac output variation was more sensitive to K_depletion whereas heart rate to K-loading.

  • PDF

토끼 유두근의 전기적 및 기계적 성질에 미치는 칼륨 및 수소이온의 영향 (Effects of $K^+$ and $H^+$ on electromechanical properties of rabbit papillary muscle)

  • 김전;김기환
    • The Korean Journal of Physiology
    • /
    • 제16권1호
    • /
    • pp.13-23
    • /
    • 1982
  • Effects of external pH and potassium concentrations on the electrical and mechanical properties were investigated on rabbit papillary muscle. Papillary muscles were perfused in horizontal chamber with Tris Tyrode solutions and action potential along with isometric tension was recorded simultaneously. Potassium concentrations were varied between 1 and 12 mM at low(6.9), normal(7.4) and high (7.9) external pH. The following results were obtained: 1) On rasing the potassium concentration from 1 to 12 mM resting membrane potentials decreased from $-88.8{\pm}2.8$ to $-66.4{\pm}1.2\;mV$ at normal pH and the amplitude of action potential decreased from $115.1{\pm}0.7$ to $97.5{\pm}2.8\;mV$. On lowering the potassium concentration, membrane hyperpolarized and at 1 mM potassium concentration resting potentials were $-107{\pm}2.2\;mV$. Duration of action potential especially $APD_{60}{\sim}APD_{90}$ increased($APD_{90}$: $214{\pm}15.8\;ms$ at 1 mM $K^+$ to $287{\pm}18.1\;ms$ at 12 mM $K^+$). 2) During acidosis membranes hyperpolarized by more than 20 mV within 1 min. and then slow recovery was observed during the following 10 min. During alkalosis membranes depolarized about 10 mV, which were maintained until washing with normal Tyrode solutions. 3) On lowering the external pH(7.9-6.5), duration of action potential increased progressively and it was most prominent at pH 6.5 and $K^+$ 1mM. 4) Magnitude of developed tension was $0.6{\pm}0.14\;g/mm^2$ at normal pH and potassium concentration (stimulus frequency : 60/min). Relative isometric tension to normal value increased along the increment of stimulus frequency($44.2{\pm}4.2%$ at 6/min to $271{\pm}86.7%$ at 180/min). Force-frequency relations were altered quantitatively during the perfusion with different external pH solutions. 5) Developed tension did not show marked variation within the range of $2{\sim}8\;mM$ potassium concentrations. Positive inotropism was observed at less than 2 mM $K^+$ and negative inotropism beyond 12 mM $K^+$ concentrations. From the above results we concluded that the effects of potassium ion concentration on electrical and mechanical properties of rabbit papillary muscle are related to the changes in surface negative charge due to acid base disturbances.

  • PDF

ELIMINATION PATTERNS OF ARTERIAL BLOOD CYANIDE ION IN THIOSULFATE-OXYGEN ADMINISTERED RABBIT

  • Yoo, Keun-Young;Lee, Yoon-Seong;Yun, Dork-Ro
    • Toxicological Research
    • /
    • 제3권2호
    • /
    • pp.89-96
    • /
    • 1987
  • To test the efficacies of thiosulfate in cyanide poisoning with or without oxygen, after the administration of sublethal dose of potassium cyanide, serial arterial blood samples were collected during 60 minutes in 15 rabbits. Cyanide ion concentrations were measured by Conway cell microdiffusion method, and arterial oxygen tensions were also observed. Comparison of elimination constants showed that arterial blood cyanide ion concentration decreased most rapidly in the thiosulfate with oxygen-administered group. The elimination of cyanide ion by the action of thiosulfate in acutely poisoned rabbit accelerated probably due to oxygen and elimination pattern seems to occur by first-order elimination kinetics.

  • PDF

토끼 동방결절 활동전압에 대한 Na, K, Ca 및 Mg 이온의 영향 (Effect of Na, K, Ca and Mg ions on the Action Potential of the Sinoatrial Node in the Rabbit)

  • 이정렬;엄융의
    • Journal of Chest Surgery
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 1985
  • Isolated sinus node cells of the rabbit were used to assess the effects of extracellular Na, K, Ca and Mg concentrations on cardiac pacemaker activity. With intracellular glass micro-electrodes spontaneous action potentials of SA node were recorded and the effects of various ions and their blockers were analyzed in terms of the cycle length, the amplitude and the duration of action potentials, the results obtained were as follows. 1. Sodium reduction [up to 30%] decreased the amplitude of action potential and lengthened the cycle length. TTX, specific blocker of Na channel slightly lengthened the cycle length. 2. Increasing potassium ion concentration, the duration of action potential decreased and the frequency increased in 6mM, however, spontaneous action potential was stopped in 24 mM. Barium ion known to be decreasing K conductance increased the duration of action potential but no significant change in the cycle length was noticed. 3. Calcium ion has shortening effect on the duration and the cycle length of action potential but not with dose-dependent manner. Cadmium ion .[0.02mM] lengthened cycle length and the duration of action potential. 4. Increasing the concentration of magnesium ion the cycle length was lengthened, significantly.

  • PDF

A Chemical Analysis of Airborne Particulates at the near Coast Site, Ul-jin Geun Gyungbook

  • Lee, Dong Sub;Park, Jin Sik
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.615-622
    • /
    • 2015
  • East Asia is characterized by anthropogenic emissions resulting from the large population and fast economic growth of this region. Since the prevailing wind is westerly and northwesterly, emissions from Ul-jin can be expected to contribute to acidic deposition increase in downwind direction. Aerosols collected at the near coast site, Uljin geun, gyungbook and were analyzed for $NH_4{^+}$, $Mg^{2+}$, $Na^+$, $Ca^{2+}$, $Cl^-$, $SO_4{^{2-}}$, and $NO_3{^-}$ from Aug. 2012 to Feb. 2013. The seasonal averaged aerosol concentration showed the highest potassium and calcium ion in winter and the highest ammonium ion due to a meadow and high solar intensity in summer. Sodium and chloride ion showed the same ratio all seasons and sulfate and nitrate species showed the maximum value in winter Chemical components of aerosols collected at the near coast site, Uljin geun, gyungbook were lower by 16 to 73% than those collected at other similar environment site such as kanghwa, yangyang. Comparing air quality data at the near coast site, Uljin geun, gyungbook, There was found that Uljin coast site is less influenced by the sea salts(potassium, magnesium, calcium) and nss-$SO_4{^{2-}}$ percentage is 3~13% higher than similar condition site.

2009년 부산지역 강수의 화학적 특성 (Characterization of Chemical Properties of Precipitation at Busan, Korea, 2009)

  • 정운선;박성화;강덕두;이동인;김동철
    • 한국환경과학회지
    • /
    • 제23권1호
    • /
    • pp.69-79
    • /
    • 2014
  • The seasonal variation of pH and ion components in precipitation were investigated from January to December 2009 at Busan, Korea. The precipitation was acidic with a volume-weighted mean pH concentration of 5.32, which ranged from 3.79 to 8.66. The volume-weighted mean conductivity showed 86.77 ${\mu}S/cm$ and indicated higher concentration about 96.69 ${\mu}S/cm$ in summer. The volume-weighted mean equivalent concentration of components followed the order: $K^+$ > $Ca^{2+}$ > $nss-Ca^{2+}$ > $NH_4^+$ > $Mg^{2+}$ > $Na^+$ > $Li^+$ in cations and $Cl^-$ > $SO_4^{2-}$ > $nss-SO_4^{2-}$ > $NO_3^-$ > $NO^{2-}$ > $F^-$ > $Br^-$ in anions. Particularly, concentration of $K^+$ and $Cl^-$ showed 56 and 78 % in cations and anions. The higher concentration in $K^+$, $Na^+$, $Mg^{2+}$ and $Cl^-$ were shown in Busan city as compared to the other cities. The neutralization factors have been found to have higher value for potassium ion in winter compared with different seasons, indicating significant neutralization of acidic components over the region by potassium. Therefore, the precipitation characteristics at Busan had both continental and coastal as consequence of pH, conductivity and ionic analyses.

hERG 칼륨채널 활성도 변화에 따른 31종 한약처방의 심장독성 평가 (Cardiotoxicity assessment of 31 herbal formulae by activity of hERG potassium channel in HEK 293 cells)

  • 하혜경;진성은;이시온;김동현;서창섭;신현규
    • 대한한의학회지
    • /
    • 제43권1호
    • /
    • pp.33-41
    • /
    • 2022
  • Objectives: Drug-induced blockade of the human ether-à-go-go related gene (hERG) potassium ion channel causes acquired long QT syndrome, which is known to cause cardiac arrhythmias and be fatal. To establish safety evidence of herbal formulae, we evaluated the effects of 31 herbal formulae on hERG channel activity. Methods: The current through hERG channel was measured by changing the membrane voltage before and after treatment with 31 herbal formulae in HEK 293 cell overexpressing hERG channel using a whole-cell patch clamp system. The current-voltage curves and the activity curves were fitted, and the hERG activity and 50% inhibitory concentration (IC50) according to each herbal formula were calculated. Results: Chokyungjongok-tang, Oncheong-eum, and Cheongsangbangpung-tang strongly inhibited the hERG activity, with IC50 values of 67.67, 141.2, and 296.3 ㎍/mL, respectively. Yeonkyopaedok-san, Eunkyo-san, Ukgan-san gajinphibanha, Daegunjoong-tang (except Oryzae gluten), Insamyangyoung-tang, Banhahubak-tang, SokyungHwalhyul-tang, Jodeung-san, Hyeonggaeyeongyo-tang, and Bangkeehwangkee-tang weakly inhibited hERG activity, with IC50 values ranging from 400 to 1000 ㎍/mL. The other 18 herbal formulae showed very weak hERG activity inhibition of less than 50% at the highest concentration (1000 ㎍/mL). Conclusion: This study provided safety information on cardiotoxicity by cardiac arrhythmia risk assessment of herbal formulae, and is expected to be a reference data for predicting the safety and risk of herbal formulae.