• 제목/요약/키워드: post-tensioned slab

검색결과 51건 처리시간 0.021초

ADAPT Edge 2012-RC/PT 다층 구조물 해석 및 설계 프로그램 (New Approach to Integrated Structural Analysis and Design for Multistory RC/Post-Tensioned Buildings)

  • Aalami, Florian;Lee, Soo Heon
    • 전산구조공학
    • /
    • 제25권4호
    • /
    • pp.63-70
    • /
    • 2012
  • This article introduces ADAPT Corporation's latest software product for the integrated multistory analysis and design of concrete buildings, ADAPT Edge. Edge uniquely packages user-friendly modeling of multistory buildings, accurate gravity and lateral analysis, post-tensioning, and detailed slab and beam design, all in one software package. The benefits of Edge over traditional concrete design software are explained.

파괴 메커니즘을 고려한 내부 포스트텐션 플랫 플레이트 슬래브-기둥 접합부의 강도식 평가 (Strength of Interior Post-Tensioned Flat Plate Slab-Column Connection based on Failure Mechanism)

  • 김민남;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.126-129
    • /
    • 2006
  • A bending moment $M_u$ transferred at slab-column connection is resisted at the slab critical section by flexure and shear. The ACI 318-05 Building Code(1) gives an empirical equation for the fraction ${\gamma}_{\upsilon}$ of the moment $M_u$ to be transferred by shear at the slab critical section at d/2 from the column face and also the effective wide(c+3h). The equation is based on tests of interior slab-column connections without shear reinforcement. In order to investigate the data eight test specimens were examined. The test shows that increased slab load substantially reduces both the unbalanced moment capacity and the lateral drift capacity of the connection. Especially, the specimens with the bottom reinforcement existence and nonexistence, appears remarkable differences. Studies also show that the code equation for ${\gamma}_{\upsilon}$ does not apply to all cases. The purpose of this study is to compare the test results with present ACI 318-05 Building Code provisions for design of slab-column connections and with the analysis of the experimental data for a new limitation of strength equation without shear reinforcement and bottom reinforcement.

  • PDF

부분 프리스트레스트 콘크리트 슬래브의 휨 균열 거동에 관한 실험적 연구 (An Experimental Study on the Flexural Cracking Behavior of Partially Prestressed Concrete Slabs)

  • 박홍용;연준희;최익창
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.108-115
    • /
    • 1990
  • This paper contains experimental studies on the flexural cracking behabior of PPC one-way slabs. Three post tensioned bonded PPC slabs with the same prestressing ratio and ultimate moment strength were tested. Based upon test results, this paper also presents the crack width prediction formula PPC slab. According to the crack theory developed mainly in Europe, crack width formula is given as the product of crack spacing and mean steel strain after decompression. Aaaaverage crack spacing formula is composed of many factors mainly such as concrete cover, concrete effective area in tension, sum of reinforcing bars perimeters and mixed reinforcements. In particular, it is very important to specify the bond characteristics of mixed reinforcements, since bond characteristics of PC bars are different from those of non-tensioned deformed bars. For this reason, a reduced bond coefficients for PS bars is employed in this study.

  • PDF

포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동 (Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems)

  • 한상환;기성훈;강현구;조종;이리형
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.595-602
    • /
    • 2006
  • 본 연구의 목적은 중력 하중에 저항하도록 설계된 플랫 플레이트 외부 접합부의 이력 거동을 평가하는 데 있다. 이러한 목적을 위하여 2/3의 크기가 조정된 PT 슬래브-기둥 외부 접합부 2개와 RC 슬래브-기둥 외부 접합부 1개를 대상으로 실험적 연구를 수행하였다. 여기서 각각의 PT 실험체는 서로 다른 강선 배치 형태를 띄고 있다. 중력 하중은 동일하게 설정하였고, 지속적인 정적 하중 하에서 유사 정적 횡하중을 적용하였다. 한편 모든 실험체는 ACI 318-05과 ACI 352.1R-89에 근거하여 기둥 폭 내에 하부 철근을 배근 하였다. 또한 PT 외부 접합부의 이력 거동에 대한 일반적인 결론을 얻기 위하여 기존 연구자들의 실험 결과와 함께 비교하였다. 이번 연구를 통하여 강선의 배치는 PT 접합부의 이력 거동을 결정하는 중요한 변수임을 확인하였다. 즉 횡변형 성능, 에너지 소산 능력, 파괴 메커니즘, 그리고 연성 능력이 강선의 배치에 따라 다르게 나타났다. 또한 ACI 352.1R-89에서 구조적 일체성을 위해 제공된 하부 철근의 양은 모멘트 역전에 의해 발생된 정모멘트를 저항하는데 있어서도 적절하다는 것이 밝혀졌다. 또한 실험체의 전단 강도는 강선의 포스트 텐션에 의한 평균 콘크리트 압축 응력($f_{pc}$)의 효과가 고려된 식이 그렇지 않은 식보다 전단 강도를 정확히 예측하는 것으로 나타났다.

Analytical study of composite steel-concrete beams with external prestressing

  • Turini, Thiago T.;Calenzani, Adenilcia F.G.
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.595-609
    • /
    • 2022
  • Prestressed composite steel-concrete beams are still a technology restricted to repair sites of large-scale structures and spans. One of the reasons for that is the absence of standard frameworks and publications regarding their design and implementation. In addition, the primary normative codes do not address this subject directly, which might be related to a scarcity of papers indicating methods of design that would align the two technics, composite beams and external prestressing. In this context, this paper proposes methods to analyze the sizing of prestressed composite beams submitted to pre-tension and post-tension with a straight or polynomial layout cable. This inquiry inspected a hundred and twenty models of prestressed composite beams according to its prestressing technology and the eccentricity and value of the prestressing force. The evaluation also included the ratio between span and height of the steel profile, thickness and typology of the concrete slab, and layout of the prestressing cables. As for the results, it was observed that the eccentricity of the prestressing force doesn't significantly influence the bending resistance. In prestressed composite beams subjected to a sagging moment, the ratio L/d can reach 35 and 30 for steel-concrete composite slabs and solid concrete slabs, respectively. Considering the negative bending moment resistance, the value of the L/d ratio must be less than or equal to 25, regardless of the type of slab. When it comes to the value of the prestressing force, a variation greater than 10% causes a 2.6% increase in the positive bending moment resistance and a 4% decrease in the negative bending moment resistance. The pre-tensioned composite beams showed a superior response to flexural-compression and excessive compression limit states than the post-tensioned ones.

언더텐션 시스템을 이용한 장스팬 구조의 처짐 거동 해석 (Deflection Analysis of Long Span Structures Using Under-Tension System)

  • 박덕근;이진;함수윤;안남식;이기학;이재홍
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.66-69
    • /
    • 2008
  • 본 연구는 도로 상부에 휴식과 통행이 가능한 공간을 조성하여 녹지 및 휴게 공간을 확보하고 각 구역간의 연결성 및 접근성을 높일 수 있는 장 스팬 구조의 처짐의 거동을 해석하는 것을 목표로 한다. 이러한 장 스팬 구조의 경우, 부재의 크기를 결정할 때 도심 미관과 하부의 차량소통을 고려하여야 한다. 그 결과 부재의 크기가 세장해지는 결과를 가져오게 되며 이는 구조물의 과다 처짐을 유발할 수가 있다, 여기에서는 부재의 크기 제한과 구조물의 과다 처짐을 방지하기 위하여 구조물 하부에 언더텐션을 적용한 후, 그 효과와 처짐 거동에 대하여 비교 분석하였다. 언더텐션이란 상부에서의 하중을 하부 케이블의 인장력을 이용하여 그 하중을 양 단부로 전달하는 시스템을 말하며, 케이블의 크기와 개수, 포스트의 개수와 크기 및 간격에 따라서 효과가 다르게 나타날 수 있다. 따라서 본 연구에서는 케이블의 크기와 개수, 포스트의 개수와 크기 및 간격을 변수로 하여 장 스팬 구조의 처짐 거동을 비교하였다. 하중은 활하중과 고정하중이 평면에 재하되는 것을 기본으로 가정하였으며, 해석결과는 상용 프로그램인 마이더스(MIDAS)를 이용하여 언더텐션의 효과를 처짐에 맞추어 비교 검토하였다.

  • PDF

PT 플랫 플레이트와 RC 플랫 플레이트 내부 접합부의 구조적 거동 비교에 관한 실험적 연구 (An Experimental Study on Comparison of Structural Behavior of PT Flat Plate and RC Flat Plate Interior Connections)

  • 이동근;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.111-114
    • /
    • 2005
  • While the existing reinforced concrete flat plate(RC flat plate) has a lot of advantages including reduced building height, it has some weak points such as many steel bars and the brittle rupture by punching shear. Compared with the RC flat plate, the post-tensioned flat plate (PT flat plate) has not only the same merits, but it also makes longer span possible and induces slab-column connections to be failed with the ductile behavior rather than with the brittle behavior by means of post-tensioning. However, it is difficult to define the joint behavior of PT flat plate under vertical and lateral loads since there are limit experimental results. For this reason, the experimental study is undertaken to investigate the comparison of behavior of PT flat plate and RC flat plate, and how flat plate(Gravity Load Resisting System) is displaced as lateral loads, like the wind and the earthquake, are occur. The result of this experiment shows that PT flat plate is generally superior to RC flat plate in terms of controlling crack, postponing stiffness deterioration, energy dissipation, etc.

  • PDF

한계상태모델을 이용한 철근콘크리트와 포스트텐션 무량판의 통합해석 (Generalized Analysis of RC and PT Flat Plates Using Limit State Model)

  • 강현구;나창순
    • 콘크리트학회논문집
    • /
    • 제21권5호
    • /
    • pp.599-609
    • /
    • 2009
  • 2층 규모의 철근콘트리트조 및 포스트텐션조 무량판구조를 1/3 스케일로 축소하여 제작한 실험체의 진동대 실험 결과를 바탕으로 무량판구조의 모델링 기법을 향상하고자 하는 연구를 수행하였다. 이 연구에서 적용한 모델링 방법은 슬래브의 휨모멘트에 의한 휨파괴, 불균형모멘트의 전달에 의한 휨파괴 및 펀칭전단파괴에 의한 슬래브-기둥 접합부의 모멘트 전달능력 상실등의 영향을 반영하는 매우 포괄적인 구조해석 방식이다. 펀칭전단파괴에 대해서는 중력비와 층간변위각에 기초한 한계상태 모델이 적용되었다. 이 논문에서 제안된 비선형 모델은 무량판구조의 진동대 실험 결과와 잘 부합하는 것으로 나타났다.

상향긴장식 부분PT를 사용한 슬래브의 적용성 분석 (A Study on the Applicability of Partial Post-Tension Slab with Top Anchorage System)

  • 이득행;김강수;김창혁;김상식;김용남;정광량
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.309-312
    • /
    • 2008
  • 철근콘크리트구조(RC)는 경제성이 뛰어나 가장 널리 사용되고 있지만, 인장응력에 취약하고 콘크리트의 자중이 커서 처짐 제어가 어렵다는 단점이 있다. 프리스트레스트콘크리트구조는 이를 극복할 수 있는 가장 효율적인 방법으로 이미 오래전부터 알려져 있지만 국내에서는 건축 현장 여건 때문에 적용사례가 매우 드물다. 특히, 대부분 부정정 구조물인 건축물에 적합하면서 일체성을 확보할 수 있는 포스트텐션(PT) 공법은 국내에서는 최근에서야 비로소 몇몇 건축 현장에 도입하기 시작하였다. 그러나 전구간 포스트텐션 공법을 적용하는 것에는 현장여건상 여전히 많은 엔지니어들이 부담을 가지고 있는 것이 현실이다. 따라서 본 연구에서는 RC구조의 처짐억제 효율성을 높이면서도 현장 실무자들에게 부담을 최소화 할 수 있는 현실적 대안으로 부분 구간에만 PT공법을 적용시키는 방법을 제안하고 거동 특성을 분석하였다. 본 연구에서는 부분 구간PT공법의 적용성을 높이기 위하여 상향긴장방식을 적용하였으며, 실제 현장적용을 통하여 얻은 계측값과 해석결과의 비교를 통하여 거동 특성을 분석하였다.

  • PDF

프리스트레스트 콘크리트 부재용 재긴장 정착구 하중전달시험 (Load Transfer Test for Re-tensioning Post-Tension Kit for Prestressed Concrete)

  • 허재훈;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.8-14
    • /
    • 2021
  • 포스트텐션 프리스트레스트 콘크리트 부재는 즉시 손실 이외에도 크리프, 건조수축 및 릴렉세이션과 같은 시간적 손실이 발생한다. 아울러 상부 슬래브 또는 포장 등의 교체 등에 의한 고정하중 변동으로 인하여 부재 상하부의 응력이 변화하게 된다. 이러한 응력의 변화는 부재의 안전성에 영향을 줄 경우가 있으며, 이 경우 프리스트레스 힘의 조절이 필요하다. 따라서 이 연구에서는 나사를 적용한 새로운 유형의 재긴장 포스트텐션 정착구를 제안하고, EAD160004 및 KCI-PS101에 규정된 하중전달시험을 통하여 하중에 대한 안전성과 변형률에 대한 안정성을 만족함을 구명하였다.