• Title/Summary/Keyword: post-curing

Search Result 139, Processing Time 0.025 seconds

Effect of Fluoride Treatment after Bleaching with Hydrogen Peroxide exposed to Plasma Arc (고농도 과산화수소와 플라즈마 아크를 이용한 미백 치료에 있어서 불소의 효과)

  • Chung, Sun-Young;Lee, Young-Eun;Ahn, Sang-Hun;Yang, Hae-Young;Jeon, Eun-Suk;Choi, Youn-Hee;Song, Keun-Bae
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.375-380
    • /
    • 2011
  • This study evaluated whether fluoride treatment can affect recovery of the irregularity of enamel surface after tooth whitening with a high concentration of hydrogen peroxide (HP) activated by plasma arc light. A total of 36 bovine teeth stained with coke were used in this experiment. The specimens were classified into following three groups (two different commercial plasma arc groups and a control group without light curing source): (1) 35% HP gel only, (2): 35% HP gel and Plasma arc A, and (3) 35% HP gel and Plasma arc B. To measure color changes and surface morphologies before and after the bleaching, colorimeter and scanning electron microscopy were used, respectively. When the specimens were bleached with hydrogen peroxide and plasma arc lights, the bleaching effect was greater than when only hydrogen peroxide gels were used (Kruskal-Wallis test, p<0.05). In addition, plasma arc B showed the more color changes than plasma arc A (Bonferroni post-hoc test, p<0.05). The surfaces of the teeth treated with fluoride gel after the whitening treatment came to be smooth. Therefore, the results of this study suggested that the fluoride application for patients who got tooth whitening therapy with a high concentration of hydrogen peroxide gels activated by plasma arc light will be effective to recover rough enamel surfaces.

Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

  • Gungor, Ahmet Yalcin;Alkis, Huseyin;Turkkahraman, Hakan
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.96-100
    • /
    • 2013
  • Objective: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III ($10.73{\pm}0.96$ MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth ($4.17{\pm}1.11$ MPa) (p < 0.001). Conclusions: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.

A Clinical Study of Bee Venom Acupuncture Therapy on Shoulder Pain Patients in Stroke Sequelae (중풍후견증(中風後遣症)으로 인한 견비통(肩譬痛) 환자(患者)의 봉약침치료(蜂藥鍼治療)에 대한 임상적(臨床的) 고찰(考察))

  • Lee, Dae-Yong;Yeom, Seung-Chul;Kim, Do-Ho;Kim, Dae-Joong;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.69-80
    • /
    • 2006
  • Objectives : The occurrence of shoulder pain after attack of stroke varies from 15% to about 80% in patients. Hemiplegic shoulder pain has been shown to affect stroke outcome in a negative way that it interferes with recovery after a stroke. These following processes have been all postulated as causes of a shoulder pain: glenohumeral subluxation, spasticity, impingement, soft tissue trauma, glenohumeral capsulitis, shoulder hand syndrome. And stroke patients may suffer from pain caused by stroke itself(central post-stroke pain). The aim of this study is to investigate the effectiveness of Bee venom therapy for shoulder pain in stroke patients. Methods : To evaluate the effectiveness of Bee Venom Acupuncture Therapy, 40 patients were allocated into control and treatment group. They were monitored for 3 weeks and followed up with VAS score(with the interval of Initial(YAS1)), 1 week later(VAS2), 2 weeks later(VAS3), 3 weeks later(VAS4), Motor Grade and Passive ROM. Results : VAS score decrease in treatment group compared to control group. Bee Venom Acupuncture Therapy seems to decrease hemiplegic shoulder pain and this effect was statistically significant after 3 weeks. Therefore this therapy could be recommended for the treatment of patients with shoulder pain after stroke and further extensive clinical studies are expected. Conclusion : We suggest that GDS oral administration and electro-acupuncture at $BL_{52}$ & $GB_{39}$ are available for prevention and curing about the postmenopausal osteoporosis.

  • PDF

Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step (연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가)

  • Hwang, Seong-Sig;Im, Yong-Woon;Kim, Si-Chul;Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

A Study on the trends of Meebyung research ('미병(未病)' 연구의 경향에 관한 고찰)

  • Lee, Sang-Jae;Li, Song-Shi;Kim, Do-Hoon
    • Journal of Korean Medical classics
    • /
    • v.23 no.5
    • /
    • pp.23-34
    • /
    • 2010
  • Contemporary topic of the culture is turning to the Nature. In this situation, The Paradigms of realization about Human body and medical science are changing. The new interpretation of the value of Health is another method of recovering the Nature. Oriental medicine has mainly dealt with health preserving idealogy in origin, and pursued it. Get out of the curing medicine, the health preserving idealogy which aims to live up to one's lifespan has been becoming the main idea of Oriental medicine. In this respect, we can extract insperation from the concept of Meebyung and preventive treatments which came from the ideas of preventive medicine in Oriental medicine. Among the researches of Meebyung in Oriental medical classics and in Oriental tri-countries, we grasped and analyzed the trends of them. In connection with the most fundamental project in Meebyung study which is to set up the concept of Meebyung, we inspected the standards which can categorize and diagnose Meebyung. In contrast with 'Ibyeong', Meebyung in Oriental medical classics can be attained from living in harmony with the Nature, four seasons, Eum-and-Yang and the Five Phases. However the classification of Meebyung, Yogbyeong, Ibyeong in medical classics made foundation of post preventive medicine. From the various studies we can find as follws. Promting national project in Meebyung, China is trying to reestablish classifications of Meebyung, as Japanese Meebyung scholars are focusing on quantitative methods. Although there are not enough research products, Korea must absorb the products of such other countries, as to categorize Meebyung through the pattern identification system of Oriental medicine, and achieve our goal of promotion of health.

COLOR CHANGES OF PALFIQUE ESTELITE BETWEEN PRE AND POST IRRADIATIONS (Palfique Estelite의 경화전후 색조 변화에 관하여)

  • Aoshima, Yutaka;Takagi, Haruhito;Sairenji, Noriko;Ikeda, Harughiko;Kuroda, Takashi;Onose, Hideo
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.10-17
    • /
    • 1997
  • It is pointed out that the color of composite resin is changing according to it's ploymerization and this color change is a harmful effect for the clinical satisfacion of composite resin restoration. The purpose of this study was to compare the changes of color of newly developed composite resins between before and after exposure of activating light. Five Compostie resins (8 shades) were employed: Palfique Estelite(UL, U, DY, G ; Tokuyama), Photo Clearfil A (US : Kuraray), Photo Clearfil Bright (US ; Kuraray), GC Graft LC(A3 ; GC), Silux Plus(U; 3M), Tristirnulus values of each material were determined before and after curing-light exposure by using a Micro Multi Photometer (MMP-1001, Nihon Denshoku Kogyo). The values were transformed into $L^*\;a^*\;b^*$ system and color changes of the resins were evaluated by the changes of $L^*$, $a^*$ and $b^*$ values for the individual shades. In addition, the effects of resin thickness and background color on color changes were also studied The finding were as follows: 1. Color changes of $L^*$, $a^*$ and $b^*$ values were recognized due to the light exposure for all products. The $b^*$ values of Palfique Estelite showed negligible changes for all shades. 2. The $b^*$ values were affected strongly by the background color, especially when decreasing the brightness on the background color.(Request original article reprints to Dr. Aoshima)

  • PDF

New Photopolymers Composed of Photoreactive Binder for Holographic Applications (I)

  • Choi, Dong-Hoon;Yoon, Han-Na;Yoon, Hyuk;Lee, Geon-Joon;Feng, De-jun;Kim, Jae-Hong;Paik, Sang-Hyun;Choi, Suk-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.230-233
    • /
    • 2003
  • New photopolymers were designed and prepared using the photosensitive polymer binders. The photochemical reaction of the photosensitive polymer binder was studied by virtue of UV absorption and infrared spectroscopy. The holographic gratings were successfully fabricated in these photopolymer film samples by conventional optical interference method. We also investigated the effect of photocrosslink in the polymer binder on the diffraction behavior of the photopolymer. The dynamic behaviors of the grating formation were studied with the change of exposure intensity in terms of the diffraction efficiency. Particularly, we focused our efforts to observe the variation of the diffraction efficiency during post UV curing process.

  • PDF

Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath (3D 프린팅용 UV 경화 수지의 조사량 및 항온수조 침적에 따른 수축률의 차이)

  • Kim, Dong-Yeon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.113-120
    • /
    • 2020
  • Purpose: This study is to compare and analyze the shrinkage of the specimen after UV irradiation of UV cured resin at 5, 15, and 30 minutes. Methods: A cylindrical UV cured specimen was produced using a stainless steel mold. UV cured resin specimens were prepared in three groups: 5 minutes cured (5M), 15 minutes cured (15M), and 30 minutes cured (30M). The measurement was made in total 3rd. The measurement was made in total 3rd. The primary measurement was made after 24 hours using a digital measuring instrument. The 2nd and 3rd measurements were deposited in a constant temperature water bath and the shrinkage was measured. The measured data was calculated by referring to the ASTM C326 linear measurement calculation method. T-test and One-way ANOVA were performed to test the significance between groups. The post-test was conducted with Tukey (α=0.05). Results: When the inner diameter and the outer diameter of the three groups not placed in the water bath were compared and analyzed, the contraction was the smallest at 6.8% in the 5M group, and the contraction was the largest at 7.3% in the 30M group. In the outer diameter, the contraction of the 5M group was the smallest at 3.5%, and the contraction of the 30M group was the largest at 4.5%. Shrinkage decreased in all three groups immersed in a water bath for 3-7 days. Conclusion: In the UV cured resin specimen, the shrinkage increased as the amount of UV irradiation increased.

Effects of relining materials on the flexural strength of relined thermoplastic denture base resins

  • Sun, Yunhan;Song, So-Yeon;Lee, Ki-Sun;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.361-366
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of relining materials on the flexural strength of relined thermoplastic denture base resins (TDBRs). MATERIALS AND METHODS. For shear bond strength testing, 120 specimens were fabricated using four TDBRs (EstheShot-Bright, Acrytone, Valplast, Weldenz) that were bonded with three autopolymerizing denture relining resins (ADRRs: Vertex Self-Curing, Tokuyama Rebase, Ufi Gel Hard) with a bond area of 6.0 mm in diameter and were assigned to each group (n=10). For flexural strength testing, 120 specimens measuring $64.0{\times}10.0{\times}3.3mm$ (ISO-1567:1999) were fabricated using four TDBRs and three ADRRs and were assigned to each group (n=10). The thickness of the specimens measured 2.0 mm of TDBR and 1.3 mm of ADRR. Forty specimens using four TDBRs and 30 specimens using ADRRs served as the control. All specimens were tested on a universal testing machine. For statistical analysis, Analysis of variance (ANOVA) with Tukey's test as post hoc and Spearman's correlation coefficient analysis (P=.05) were performed. RESULTS. Acry-Tone showed the highest shear bond strength, while Weldenz demonstrated the lowest bond strength between TDBR and ADRRs compared to other groups. EstheShot-Bright exhibited the highest flexural strength, while Weldenz showed the lowest flexural strength. Relined EstheShot-Bright demonstrated the highest flexural strength and relined Weldenz exhibited the lowest flexural strength (P<.05). Flexural strength of TDBRs (P=.001) and shear bond strength (P=.013) exhibited a positive correlation with the flexural strength of relined TDBRs. CONCLUSION. The flexural strength of relined TDBRs was affected by the flexural strength of the original denture base resins and bond strength between denture base resins and relining materials.

Color quality evaluation of composite resins used for splinting teeth (동요치 고정에 사용되는 복합레진의 색품질 평가)

  • Jung, Ji-Hye;Cheon, Kyeong Jun;Oh, Yonghui;Chang, Hoon-Sang
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.995-1002
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the color stability of composite resins used for splinting teeth by comparing a self-cure resin cement (Superbond C&B, SB), a flowable composite resin (G-aenial Universal Flo A2, GU), and a composite resin exclusively used for splinting teeth (G-Fix, GF) before and after aging in NaOCl. Methods: Resin samples were fabricated to a size of 2 mm thickness and 8.5 mm diameter and light-cured with an LED light curing unit (G-Light, n = 12). Immediately after fabrication, CIE L*a*b* values of the resin samples were measured with a spectrophotometer (CM-5) as baseline. Then, the resin samples were immersed in 5% NaOCl at $60^{\circ}C$ and the color was measured after 23 hours every day for 4 days. Data were analyzed with one-way ANOVA followed by Duncan post hoc test (p<0.05), and color differences (${\Delta}E$) of resin samples before and after NaOCl aging were also calculated. Results: For SB, there were no changes in L* and a* values but changes were observed in b* values. For GU, there were no changes in L* and b* values but in a* values. For GF, changes were observed in L*, a*, and b* values. All resin samples showed highest ${\Delta}E$ between baseline and the 1st day of NaOCl immersion. ${\Delta}E$ of SB, GU, and GF was 4.6 - 5.8, 4.9 - 7.9, and 9.9 - 16.9, respectively. GF showed highest color change during NaOCl aging. Conclusion: The results of this color quality evaluation showed that the composite resin exclusively used for splinting teeth might be more vulnerable to color change during intraoral service.