• Title/Summary/Keyword: post-collision

Search Result 91, Processing Time 0.025 seconds

The Present Status of Development of Inductively Coupled Plasma Simulator based on Fluid Model (유체 모델을 기반으로 하는 유도 결합 플라즈마 시뮬레이터 개발 현황)

  • Kwon, D.C.;Yoon, N.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.151-163
    • /
    • 2009
  • The domestic development status of Inductively Coupled Plasma (ICP) simulator which is based on fluid model is explained. As each part which composes the unified simulator, electron heating module, charged and neutral particle transport module, surface reaction module including a sheath model, and GUI (Graphic User Interface) with pre- and post-processors are described in order. Also, we present data base status of chemical reaction and physical collision, which has been applied to the recently developed simulator until now. Lastly, some future plans of development are suggested.

A Study on the Injury Criteria of the Occupant Protection Performance of Crush Cushions (충격흡수시설의 탑승자보호 성능평가 기준에 관한 연구)

  • Lim, Jae-Moon;Jung, Geun-Seup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • The performance of crash cushion systems is certified through the full scale crash tests by the standard for installation and maintenance guidelines for roadside safety appurtenance. The impact severities of impacting vehicles in collision with crash cushion systems are rated by indices THIV and PHD. Crash test results are considered to study the performance of three crash cushion systems. In case of the frontal impact or the offset frontal impact, the results show that THIV values of three systems are very close to the threshold limit for the occupant protection. Also, the results show that PHD would be improper for the occupant protection performance index. In order to improve the occupant protection performance of crash cushions, ASI needs to be included in the impact severity index.

Reliability Assessment of Tubular Markers Used for Road Safety Facilities (도로안전시설용 시선유도봉의 신뢰성 평가)

  • Koo, Hyun-Jin;Yoon, Ye-Seok
    • Journal of Applied Reliability
    • /
    • v.12 no.2
    • /
    • pp.91-103
    • /
    • 2012
  • Tubular markers for road safety facilities are used to lead the driver's sight line and separate the lanes on the road. Such tubular markers are usually installed on the road and frequently hit by vehicles, they are accordingly requested to assure the product durability. The traditional evaluation method of tubular markers include only quality tests of the material properties. However, most of consuming agencies in charge of road management at fields have proposed problems on long-term performance of the products hit by vehicles under various weather conditions. Therefore, the objectives of this study are to develop the reliability test methods and equipments to simulate the product failures of tubular markers due to vehicle collision and wheel compression and the delamination and discoloration of reflection sheets attached on the surface of the products under high and low temperatures.

NUMERICAL ANALYSIS OF PHASE CHANGE AND SPRAY, MHD FLOW USING A NUFLEX (NUFLEX의 상변화, 분무유동 및 MHD 해석)

  • Ro, Kyoung-Chul;Ryou, Hong-Sun;Kang, Kwan-Gu;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • v.12 no.2
    • /
    • pp.32-36
    • /
    • 2007
  • NUFLEX is a general purpose program for the analysis 3D thermo/fluid flow and pre/post processor in a complex geometry. NUFLEX is composed of various physical models, such as phase change(solidification/melting) and spray, MHD(Magneto Hydraulic Dynamics) models. It is possible to simulate continuous cast iron process and spray droplet breakup/collision phenomenon. For the verification of these models, compared with the experimental data and commercial CFD code's results. The results show good agreements with experimental and comercial CFD codes's results.

NUMERICAL ANALYSIS OF PHASE CHANGE, SPRAY AND MHD FLOW USING A NUFLEX (NUFLEX의 상변화, 분무유동 및 MHD 해석)

  • Ryou, Hong-Sun;Ro, Kyoung-Chul;Kang, Kwan-Gu;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.99-102
    • /
    • 2007
  • NUFLEX is a general purpose program for the analysis 3D thermo/fluid flow and pre/post processor in a complex geometry. NUFLEX is composed various physical models, such as phase change(solidification/melting) and spray, MHD(Magneto Hydraulic Dynamics) models. It is possible to simulate of continuous cast iron process and spray droplet breakup/collision phenomenon. For the verification of these models, compared with the experimental data and commercial CFD code's results. The results show good agreements with experimental and comercial CFD codes's results.

  • PDF

Development of 5-axis $CO_2$ Laser Cutting Machine and CAM (5축 CO2 레이저 컷팅 머신 및 CAM 시스템 개발)

  • Kang Jae-Gwan;Yeom S.B.;Kang B.S.;Lee H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.245-246
    • /
    • 2006
  • For developing 5-axis laser cutting systems, many problems such as rotating of laser head or table, 5-axis tool path generation and collision avoidance between laser head and product should be solved. In this paper, a five-axis laser cutting machine with table swivel and rotary type configuration is developed. The five axes (X,Y,Z,A,B) are controlled and interfaced to PC via MMC board. Two kinds of CAM S/W such as commercial 5-axis CAM S/W(Euclid) and UG-API are engaged to generate NC code for the developed 5-axis laser cutting machine.

  • PDF

Delayed Post-Traumatic Spinal Cord Infarction with Quadriplegia: A Case Report

  • Kim, Tae Hoon
    • Journal of Trauma and Injury
    • /
    • v.34 no.4
    • /
    • pp.279-283
    • /
    • 2021
  • Traumatic spinal cord infarction is a rare condition that causes serious paralysis. The regulation of spinal cord blood flow in injured spinal cords remains unknown. Spinal cord infarction or ischemia has been reported after cardiovascular interventions, scoliosis correction, or profound hypotension. In this case, a 52-year-old man revisited the emergency center with motor and sensory abnormalities in all four extremities 56 hours after a motor vehicle collision. Despite the clinical presentation and imaging examination, there were no specific findings on the patient's first visit to the trauma center. Cervical spine computed tomography angiography showed a narrow vertebral artery, and diffusion-weighted imaging revealed spinal cord infarction from C3 to C5 with high signal intensity. It should be kept in mind that delayed-onset spinal cord infarction may occur in minor or major trauma patients as a result of head and neck injuries.

Development of a Robot System for Automatic De-palletizing of Parcels loaded in Rolltainer (롤테이너 적재 소포를 자동으로 디팔레타이징하기 위한 로봇 시스템 개발)

  • Kim, Donghyung;Lim, Eul Gyoon;Kim, Joong Bae
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.4
    • /
    • pp.431-437
    • /
    • 2022
  • This paper deals with a study on the automatic depalletizing robot for parcels loaded in rolltainer of domestic postal distribution centers. Specifically, we proposed a robot system that detect parcels loaded in a rolltainer with a 3D camera and perform de-palletizing using a cooperative robot. In addition, we developed the task flow chart for parcel de-palletizing and the method of retreat motion generation in the case of collision with rolltainer. Then, we implemented the proposed methods to the robot's controller by developing robot program. The proposed robot system was installed at the Anyang Post Distribution Center and field tests were completed. Field tests have shown that the robotic system has a success rate of over 90% for depalletizing task. And it was confirmed that the average tact time per parcel was 7.3 seconds.

BLACK HOLES IN GALACTIC NUCLEI: ALTERNATIVES AND IMPLICATIONS

  • Lee, Hyung-Mok
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.89-96
    • /
    • 1992
  • Recent spectroscopic observations indicate concentration of dark masses in the nuclei of nearby galaxies. This has been usually interpreted as the presence of massive black holes in these nuclei. Alternative explanations such as the dark cluster composed of low mass stars (brown dwarfs) or dark stellar remnants are possible provided that these systems can be stably maintained for the age of galaxies. For the case of low mass star cluster, mass of individual stars can grow to that of conventional stars in collision time scale. The requirement of collision time scale being shorter than the Hubble time gives the minimum cluster size. For typical conditions of M31 or M32, the half-mass radii of dark clusters can be as small as 0.1 arcsecond. For the case of clusters composed of stellar remnants, core-collapse and post-collapse expansion are required to take place in longer than Hubble time. Simple estimates reveal that the size of these clusters also can be small enough that no contradiction with observational data exists for the clusters made of white dwarfs or neutron stars. We then considered the possible outcomes of interactions between the black hole and the surrounding stellar system. Under typical conditions of M31 or M32, tidal disruption will occur every $10^3$ to $10^4$ years. We present a simple scenario for the evolution of stellar debris based on basic principles. While the accretion of stellar material could produce large amount of radiation so that the mass-to-light ratio can become too small compared to observational values it is too early to rule out the black hole model because the black hole can consume most of the stellar debris in time scale much shorter than mean time between two successive tidal disruptions. Finally we outline recent effort to simulate the process of tidal disruption and subsequent evolution of the stellar debris numerically using Smoothed Particle Hydrodynamics technique.

  • PDF

77 GHz Waveguide VCO for Anti-collision Radar Applications (차량 충돌 방지 레이더 시스템 응용을 위한 77 GHz 도파관 전압 조정 발진기)

  • Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1652-1656
    • /
    • 2014
  • In this work, we demonstrated a 77 GHz waveguide VCO with transition from WR-12 to WR-10 for anti-collision radar applications. The fabricated waveguide VCO consists of a GaAs-based Gunn diode, a varactor diode, a waveguide transition, and two bias posts for operating as a LPF and a resonator. The cavity is designed for fundamental mode at 38.5 GHz and operated at second hormonic of 77 GHz. The waveguide transition has a 1.86 dB of insertion loss and -30.22 dB of S11 at the center frequency of 77 GHz. The fabricated VCO achieves an oscillation bandwidth of 870 MHz. Output power is from 12.0 to 13.75 dBm and phase noise is -100.78 dBc/Hz at 1 MHz offset frequency from the carrier.