• Title/Summary/Keyword: positron camera

Search Result 18, Processing Time 0.022 seconds

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

Resolution Improvement of the Positron Computerized Tomographic System with Hardware Approach and Superresolution Technique

  • Hong, Ki-Sang;Ra, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.162-163
    • /
    • 1979
  • A new detector array scheme for the positron camera for tile improved image resolution and a method for the resolution improvement of the undersampled projection data from ring positron camera are proposed. Computer simulation results are presented and problems ana limitations are discussed.

  • PDF

Resolution Improvement of the Positron Computerized Tomography with a New Positron Camera Tomographic System (분해능 향상을 위한 새로운 양전자 단층 촬영기의 제안)

  • Hong, Ki-Sang;Ra, Jong-Beom
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.6
    • /
    • pp.22-30
    • /
    • 1979
  • A new circular ring position camera tomographic system termed "Oscillatory Dichotomic Ring" system is proposed and its performance is simulated. It is basically a circular ring system, composed of two half rings, which has the capability of scanning so that any sampling intervals can be obtained. Since finer sampling means poorer photon statistcs, simulations with varous signal dependent statistical noise effects, ray sampling and arrangement as well as related artifacts peculiar to the proposed Dichotomic Ring system are made.

  • PDF

Gamma Camera Based FDG PET in Oncology

  • Park, Chan-Hui
    • 대한핵의학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.45-53
    • /
    • 2002
  • Positron Emission Tomography(PET) was introduced as a research tool in the 1970s and it took about 20 years before PET became an useful clinical imaging modality. In the USA, insurance coverage for PET procedures in the 1990s was the turning point, I believe, for this progress. Initially PET was used in neurology but recently more than 80% of PET procedures are in oncological applications. I firmly believe, in the 21st century, one can not manage cancer patients properly without PET and PET is very important medical imaging modality in basic and clinical sciences. PET is grouped into 2 categories : conventional(c) and gamma camera $based_{(CB)}$ PET. $_{CB}PET$ is more readily available utilizing dual-head gamma cameras and commercially available FDG to many medical centers at low cost to patients. In fact there are more $_{CB}PET$ in operation than cPET in the USA. $_{CB}PET$ is inferior to cPET in its performance but clinical studies in oncology is feasible without expensive infrastructures such as staffing, rooms and equipments. At Ajou university Hospital, CBPET was installed in late 1997 for the first time in Korea as well as in Asia and the system has been used successfully and effectively in oncological applications. Ours was the fourth PET operation in Korea and I believe this may have been instrumental for other institutions got interested in clinical PET. The fellowing is a brief description of our clinical experience of FDG CBPET in oncology.

  • PDF

FDG-PET and MDP scan findings in chronic osteomyelitis of the left femur (좌측 대퇴골에 발생한 만성골수염의 PET와 MDP scan 영상)

  • Park, Chan-H.;Lee, Myoung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.143-145
    • /
    • 2002
  • A 49-year-old male patient with a carcinoma of the right pyriform sinus had a whole-body bone scan and gamma camera based F-18 FDG-PET for staging. Tc-99m MDP bone scan depicted diffuse increased uptake in the left femur due to chronic osteomyelitis but no skeletal metastasis. F-18-FDG-PET revealed increased focal bone uptake and uptake in the draining sinus due to chronic osteomyelitis in addition to visualization of the right pyriform sinus carcinoma and right neck nodal uptake. Fluorine-18 fluorodeoxyglucose-positron emission tomography is significantly more accurate than the bone scan in pinpointing chronic osteomyelitis focus and draining soft tissue infection.

Incidental detection of myocardial ischemia during F-18 FDG CoDe PET for the evaluation of a solitary pulmonary nodule

  • Park, Chan-H.;Park, Kwang-J.;Lee, Myoung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.398-400
    • /
    • 2001
  • The authors report a case of unsuspected myocardial ischemia detected during CoDe FDG PET (coincidence detection fluorodeoxyglucose positron emission tomogram) which was performed for the evaluation of a solitary pulmonary nodule. Camera-based FDG PET without attenuation correction often reveals false defect in the inferior wall of the left ventricle in normals due to excessive attenuation. However, this asymptomatic patient had increased uptake in the inferior wall suggesting ischemic myocardium. The scan finding was confirmed by Tl-201 myocardial SPECT and coronary angiogram. The patient then underwent successful PTCA of mild RCA and right ventricular branch followed by right upper lobectomy for small cell lung cancer.

  • PDF

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF

Development of Drugs and Technology for Radiation Theragnosis

  • Jeong, Hwan-Jeong;Lee, Byung Chul;Ahn, Byeong-Cheol;Kang, Keon Wook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.597-607
    • /
    • 2016
  • Personalized medicine is tailored medical treatment that targets the individual characteristics of each patient. Theragnosis, combining diagnosis and therapy, plays an important role in selecting appropriate patients. Noninvasive in vivo imaging can trace small molecules, antibodies, peptides, nanoparticles, and cells in the body. Recently, imaging methods have been able to reveal molecular events in cells and tissues. Molecular imaging is useful not only for clinical studies but also for developing new drugs and new treatment modalities. Preclinical and early clinical molecular imaging shows biodistribution, pharmacokinetics, mechanisms of action, and efficacy. When therapeutic materials are labeled using radioisotopes, nuclear imaging with positron emission tomography or gamma camera can be used to treat diseases and monitor therapy simultaneously. Such nuclear medicine technology is defined as radiation theragnosis. We review the current development of drugs and technology for radiation theragnosis using peptides, albumin, nanoparticles, and cells.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF