• 제목/요약/키워드: positive column discharge

검색결과 14건 처리시간 0.027초

Emission Characteristics of Discharge Tube with Mixed Gases

  • Jo, Ju-Ung;Park, Yong-Sung;Lee, Jong-Chan;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.136-139
    • /
    • 2003
  • The positive column of a discharge tube filled with a mixture of mercury-xenon has a tendency to become contracted at room temperature. However, once the tube temperature is raised over 50 [$^{\circ}C$], the positive column changes from a contracted state to a diffused state. The xenon emission is stronger in the contracted positive column than in the diffused column. Alternatively, the mercury emission is more intense in the diffused positive column, and the luminance of the phosphor coating on the inner surface of the tube is higher than that in the contracted positive column. Moreover, higher luminance can be obtained by increasing the xenon pressure.

High Efficacy and High Speed Addressing of a Spatial Positive Column Discharge PDP

  • Shiga, T.;Mikoshiba, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.115-118
    • /
    • 2007
  • Luminous efficacy of 6.0 lm/W has been realized by introducing a spatial positive column discharge together with delayed D pulses, shared sustain pulse voltage, and low sustain frequency drive. Also a high speed addressing of $0.25{\mu}s$ was achieved. The luminance was $157cd/m^2$, which is high enough for a 260-in. FHD display.

  • PDF

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

횡자계 인가시 저압 수은-아르곤 방전등의 광출력특성 (Light-Output Characteristics of a Low-Pressure Mercury-Argon Discharge Lamp in a Transverse Magnetic Field)

  • 여인선;박왕렬
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.9-12
    • /
    • 1989
  • ABSTRACT -- Recently, a method of magnetically-enhanced discharge columns is considered to increase the luminous efficacy of discharge lamps, which is based upon the face that the diffusion motion of charged particles in the discharge column strongly depends on the applied magnetic fields. This study investigates the effect of applied transverse magnetic fields on the light output of low-pressure Hg-Ar discharge. As a result, it is found that the electric field in the positive column increases according to the applied megnetic field, which causes an increase in the total light output. And this effect is much more pronounced upon the spectral line originating form the higher levels.

  • PDF

플라즈마진동을 이용한 기체크로마토그래프의 검출기에 대한 연구 (Study on the Plasma Oscillation for Gas Chromatographic detector)

  • 김효진;맹대영;강종성
    • 분석과학
    • /
    • 제6권4호
    • /
    • pp.369-374
    • /
    • 1993
  • 플라즈마 진동 현상은 글로우방전을 이용한 기체크로마토그래프 검출기의 개발 과정에서 측정되었으며 전류의 변화에 비하여 매우 안정하며 낮은 검출한계로 새로운 검출기로의 개발 가능성이 높다. 플라즈마 진동의 최적 조건과 메카니즘을 규명하기 위하여 몇 가지 실험조건을 변화시키며 관찰하였다. 즉, 방전전압(전류), 압력, 그리고 방전전극 간격을 변화시킨 결과 다양한 형태의 진동이 10KHz에서 10MHz까지의 주파수 범위에서 관찰되었다. 특히 방전전극 간격에 따라 낮은 압력과 전압의 조건에서 두 가지 형태의 진동이 나타났다. 한 가지 형태는 positive column 영역에서, 또 다른 하나는 negative glow 영역에서 측정되었다. Positive column 영역보다 negative glow 영역에서 발생된 플라즈마 진동이 훨씬 더 높은 감도 변화와 더 큰 주파수를 보였다.

  • PDF

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

변조된 수은-희유기체 교류방전의 양광주 내의 반경방향 입자분포 (Radial Density Distributions in the Positive Column of a Strongly Modulated Mercury-rare gas AC Discharge)

  • 이진우;여인선
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권2호
    • /
    • pp.31-35
    • /
    • 1993
  • 본 논문은 t은과 10[torr]의 희유기체의 혼합기체 중에서 심하게 변조된 저압기체방전의 양광주의 반경방향 압자분포를 이론적으로 연구하였다. 전류는 깊이 50[%[로 정현파로 변조되었다. 계산결과 여기 원자의 반경방향 분포는 0차 Bessel 함수 $J_0(2.4r/R)$와 다르고 분포의 반전이 나타나는 주파수 대역도 있었다. 연립미분방정식을 풀기 위하여 FDM과 2계 Runge-Kutta method의 혼합법을 사용하였다.

  • PDF

주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube with the Variation of Frequency)

  • Lee, Jong-Chan;Park, Dae-Hee
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF

A Study on the Control of Luminous Color in Gas Discharge Tubes

  • Lee, Jong-Chan;Her, In-Sung;Park, Yong-Sung;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, pulsed discharge is used to control the luminous color in gas discharge tubes. The luminous color of the positive column in gas discharge tubes filled with Hg-Ar-Ne (1: 9, 60[Torr]) and having no phosphor material, varies from red to blue emitted by the Ne and Hg from the pulsed discharge. With changing of pulse-width and frequency, the electron temperature in the transient period affects changes to the residual ion and metastable atom densities. The first metastable atoms containing energy levels of about 16.6 [eV]have a very high probability that a collision will result in the ionization potential of Ar being 15.8 [eV]. The change of locus in the CIE chromaticity diagram with increasing pulse-width and frequency approves the variation of luminous color.

온도에 따른 D.C. 저압방전의 전기적 특성해석 (Analysis of electrical Charactersitics by the effect of ambient temperature in D.C. low-pressure discharge)

  • 김수길;이진우;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.13-16
    • /
    • 1990
  • 균일한 positive column의 상세한 이론이 충돌 단면적 곡선과 공진 방사 그리고 다단계 여기(multistage)와 이온화 과정을 고려하여 0.5에서 5mmHg 압력에서 수은과 희유가스(rare-gas)가 혼합되어 있는 D.C.형광 램프 방전에 대해 전개된다. 온도와 이온, 비여기원자, 여기원자의 밀도가 수치해석에 의하여 계산된다.

  • PDF