• Title/Summary/Keyword: positional deviation

Search Result 32, Processing Time 0.021 seconds

An Arc Sensor and Its Interface System for Welding Robots (용접로봇용 아크센서 및 인터페이스 시스템)

  • 오승준;김재웅
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.76-82
    • /
    • 2000
  • An arc sensor system to compensate positional errors was developed on the foundation of sensor interface system to make use of the on-line shift function of industrial welding robot. Investigating the on-line shift function, we examine the quantitative relationship between the deviation from programmed path and the correction data transferred from personal computer to robot controller. The number of input parameters for weld seam tracking can be reduced by making the relationship between the deviation and the correction data during half weaving be the function of only cross time. With the results of weld seam tracking for the butt joint with V-groove and fillet joint of sheet metal, good performance was implemented. By developing the sensor interface system to compensate the positional errors, industrial welding robot can be expected to contribute to the promotion of welding automation.

  • PDF

Positional deviation between CBCT-based digital facebow transfer and analog facebow transfer: case series (CBCT 기반 디지털 안궁이전과 아날로그 안궁이전의 위치 편차: 증례보고)

  • Myung Hyun Park;Keunbada Son;Hwi-Gyun Ahn;Du-Hyeong Lee;So-Yeun Kim;Kyu-Bok Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.176-185
    • /
    • 2023
  • Facebow transfer is essential for accurately mounting a dental cast onto a semi-adjustable articulator. The precision of traditional analog facebow transfer is influenced by both the accuracy of the equipment used and the skill level of the operator. Considering that substantial positional deviations can adversely affect the quality of a fabricated dental prosthesis; it is critical to assess the positional accuracy of casts mounted using analog facebow transfer. This case report evaluates the linear and angular deviations of the occlusal plane for maxillary casts mounted through both analog facebow transfer and cone-beam computed tomography-based methods. The findings indicate that analog facebow transfer produced a linear deviation ranging from 3 to 16 mm and an angular deviation of the occlusal plane between 5 to 7 degrees. This case report confirms that, across two patients, analog facebow transfer can result in varying degrees of positional deviation, thereby potentially leading to inaccuracies in the fabrication of dental prostheses. These results suggest that, in clinical practice, the use of analog facebow transfer may yield significant deviations during the process of mounting maxillary casts.

Development of Color Inspection System of Printed Texture using Scanner (스캐너를 이용한 직물의 색상검사기 개발)

  • 조지승;정병묵;박무진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.70-75
    • /
    • 2003
  • It is very important to inspect the color of printed texture in the textile process. The standard colorimetric system used for the recognition of the color in the textile industry. It uses XYZ color system defined by CIE (Commission Internationale de 1Eclairage), but is too expensive. Therefore, in this paper, we propose a color inspection system of the printed texture using a color scanner. Because the scanner uses RGB value for color, it is necessary the mapping from RGB to XYZ. However, the mapping is not simple, and the scanner has even positional deviation because of the geometric characteristics. To transform from RGB to XYZ, we used a NN (neural network) model and also compensated the positional deviation. In real experiments, we could get fairly exact XYZ value from the proposed color inspection system in spite of using a color scanner with large measuring area.

Relationship between chin deviation and the position and morphology of the mandible in individuals with a unilateral cleft lip and palate

  • Kim, Kyung-Seon;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.168-177
    • /
    • 2013
  • Objective: In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods: Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results: For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions: UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance.

THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT (3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구)

  • Lee, Sang-Han;Nam, Jeong-Hun;Jung, Chang-Wook;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

RELATIONSHIP OF THE MAXILLARY CUSPID AND ALA-LACRIMAL DUCT LINE (정상인(正常人)에 있어서의 상악(上顎) 견치(犬齒)와 비익(鼻翼) 및 누관(淚管)과의 위치적(位置的) 관계(關係))

  • Jhin, Chang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.35-40
    • /
    • 1976
  • The author observed the positional relationship of maxillary cuspid to ala-lacrimal duct line in the 594 Koreans(329 male, 265 female) who had relatively normal teeth arrangement, aged 16 to 70. The relationship of ala-lacrimal duct line to the distal angie of maxilly cuspid of the subjects were classified as follows; Type A : Ala-lacrimal duct line was lotated more medially than the distal angle of maxillary cuspid. Type B : Ala-lacrimal duct line coincided with the distal angle of maxillary cuspid. Type C: Ala-lacrimal duct line was located more distally than the distal angle of maxillary cuspid. The occlusal relationship of the maxillary first molar to the mandibular first molar of the subjects were classified as follows; Group I : Group of neutrocclusion relationship. Group II : Group of distocclusion relationship. Group III : Group of mesiocclusion relationship. The obtained results were as follows; 1) The positional relationship of maxillary cuspid to ala-lacrimal duct line were as follows; (Male) Type A: $68.5%{\pm}1.58m%$, Type B: $22.5%{\pm}2.30m%$, Type C: $9.1%{\pm}\1.58m%$ (Female) Type A : $64.5%{\pm}2.94m%$, Type B: $26.5%{\pm}2.71m%$, TypeC: $8.9%{\pm}1.73m%$ 2) Ala-lacrimal duct line located more distally in group II and group III than group I at the point of the positional relationship of upper and lower first molar. 3) Average distance and standard deviation in type A were as follows; (Male) Right: $2.17mm.{\pm}1.01mm.$ Left: $2.27mm.{\pm}1.02mm.$ (Female) Right: $2.06mm.{\pm}0.70mm.$ Left: $2.24mm.{\pm}0.80mm.$ 4) Average distance and standard deviation in type C were as follows; (Male), Right: $1.47mm.{\pm}0.85mm.$ Left: $1.52mm.{\pm}0.97mm.$ (Female) Right: $1.04mm.{\pm}0.44mm.$ Left: $1.26mm.{\pm}0.89mm.$ The results of 3) and 4) had no significant difference between the male and female.

  • PDF

Horizontal change of philtrum after orthognathic surgery in patients with facial asymmetry

  • Joh, Yewon;Park, Hyun Soo;Yang, Hoon Joo;Hwang, Soon Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.48.1-48.7
    • /
    • 2019
  • Background: Soft tissue asymmetry such as lip canting or deviation of the philtrum is an important influencing factor for unbalanced facial appearance. Lip canting could be improved by the correction of the occlusal canting or positional change of the mentum. Although there are many studies about changes of lip canting, however, postoperative changes of philtrum deviation have not been yet reported. In this study, we investigate the positional change of the philtrum after orthognathic surgery and influencing factors. Methods: Positional change of the philtrum was evaluated in 41 patients with facial asymmetry who underwent bimaxillary surgery, in relation to other anatomical soft tissue landmarks using a frontal clinical photo. The surgical movement of the maxillary and mandibular dental midline and canting were measured in postero-anterior cephalogram before and 1 day after surgery. The same procedure was repeated in patients with more than 1.5 mm perioperative change of the mandibular dental midline after bimaxillary surgery. Results: Maxillary dental midline shifting and canting correction did not have a significant correlation with lateral movement of the philtrum midline. However, the mandibular shift had a statistically significant correlation with a lateral movement of the philtrum (p < 0.05) as well as other linear parameters and angle values. Conclusion: The horizontal change of the philtrum is influenced by lateral mandibular movement in patients with facial asymmetry, rather than maxillary lateral movement.

Calibration of Scanner at Color Inspection of printed Texture (직물의 색상검사에서 스캐너의 편차 보정)

  • 정병묵;조지승;박무진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.383-386
    • /
    • 2002
  • It is very important to inspect color of printed texture in the textile process. To distinguish the color of the printed texture, RGB color values obtained from a scanner must be transformed to the standard colorimetric system used in the textile industry. It is XYZ color system that is defined by CIE(Commission Internationale do 1Eclairage). The mapping from RGB to XYZ color values is not simple and the scanner has even a positional deviation of RGB colors. In this paper an automatic color inspection method using a general scanning machine is presented. We used a U(neural network) model to map RGB to XYZ and compensate the positional error. In the real experiments, this inspection system shows to get very exact XYZ values from the traditional scanner regardless of the measuring position.

  • PDF

Monte-Carlo Simulation and measuring for Error Analysis of 3-axis SCARA Robot using Observability (관측성을 이용한 3축 SCARA Robot의 오차분석을 위한 Monte-Carlo simulation 및 측정)

  • Ju, Ji-Hun;Chung, Won-Jee;Kim, Jung-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 2008
  • This paper aims at finding out dominant robot configurations with maximal position errors, which can be attributed to the parameter errors, by using Monte-Carlo simulation for error analysis of a 3-axis SCARA(Selective Compliance Assembly Robot Arm) type robot. In particular, the Monte-Carlo simulation is used for virtually measuring on the position errors, instead of physical measurement. In order to measure the observability of the model parameters with respect to a set of robot configurations, we propose the observability index which is defined as the product of singular values for error propagation matrices. Thus the index can be used for discriminating dominant robot configurations from a set of simulated ones in conjunction with standard deviation of positional errors, This paper analyzed error by robot positional error.