• Title/Summary/Keyword: position-dependent processing time

Search Result 18, Processing Time 0.02 seconds

Dynamic Characterization of Noise and Vibration Transmission Paths in Linear Cyclic Systems (I)-Theory-

  • Kim, Han-Jun;Cho, Young-Man
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1051-1060
    • /
    • 2000
  • Linear cyclic systems (LCS's) are a class of systems whose dynamic behavior changes cyclically. Such cyclic behavior is ubiquitous in systems with fundamentally repetitive motions (e. g. all rotating machinery). Yet, the knowledge of the noise and vibration transmission paths in LCS's is quite limited due to the time-varying nature of their dynamics. The first part of this two-part paper derives a generic expression that describes how the noise and/or vibration are transmitted between two (or multiple) locations in the LCS's. An analysis via the Fourier series and Fourier transform (FT) plays a major role in deriving this expression that turns out to be transfer function dependent upon the cycle position of the system. The cyclic nature of the LCS' transfer functions is shown to generate a series of amplitude modulated input signals whose carrier frequencies are harmonic multiples of the LCS' fundamental frequency. Applicability of signal processing techniques used in the linear time-invariant systems (LTIS's to the general LCSs is also discussed. Then, a criterion is proposed to determine how well a LCS can be approximated as a LTIS. In Part II, experimental validation of the analyses carried out in Part I is provided.

  • PDF

The Center Locus Estimation of the Evoked Potential Distributions During Visual Stimulation in Human (시각 자극 동안의 유발성 전위분포 의 중심점 추적에 관한 연구)

  • Park, Gwang-Seok;Min, Byeong-Gu;Lee, Chung-Ung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.3
    • /
    • pp.6-12
    • /
    • 1983
  • The visual evoked potentials were measured using 19 electrodes attached to the scalp in 5 normal and 4 abnormal subjects during visual stimulation and these data were sampled for computer processing with 500 Hz sampling frequency. The center of potential distributions and its time-dependent locus were estimated from these potential distributions using weighting matrix which was determined by the electrodes' position coordinates. In normal subjects these estimated electrical signals were shown to propagate from the frontal lobe to the occipital lobe of the cortex following the known visual pathway. In abnormal subjects, there were significant differences in these estimated propagation pathway. The relationships among this model, the point source model and the dipole source model were analyzed.

  • PDF

A Shaking Snake for Contour Extraction of an Object (물체의 윤곽선 추출을 위한 진동 스네이크)

  • Yoon, Jin-Sung;Kim, Kwan-Jung;Kim, Gye-Young;Paik, Doo-Won
    • The KIPS Transactions:PartB
    • /
    • v.10B no.5
    • /
    • pp.527-534
    • /
    • 2003
  • An active contour model called snake is powerful tool for object contour extraction. But, conventional snakes require exhaustive computing time, sometimes can´t extract complex shape contours due to the properties of energy function, and are also heavily dependent on the position and the shape of an initial snake. To solving these problems, we propose in this paper an improved snake called "shaking snake", based on a greedy algorithm. A shaking snake consist of two steps. According to their appropriateness, we in the first step move each points directly to locations where contours are likely to be located. In the second step, we then align some snake points with a tolerable bound in order to prevent local minima. These processes shake the proposed snake. In the experimental results, we show the process of shaking the proposed shake and comparable performance with a greedy snake. The proposed snake can extract complex shape contours very accurately and run fast, approximately by the factor of five times, than a greedy snake.

Design of an Activity Recognition System using Smartphone Accelerometer (스마트폰 가속도 센서를 이용한 행위 인식 시스템의 설계)

  • Kim, Joo-Hee;Nam, Sang-Ha;Heo, Se-Kyeong;Kim, In-Cheol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 2013
  • Activity recognition using smartphone accelerometer suffers from the user dependency problem that acceleration patterns of one user differ from those of others for the same activity. Moreover, it also suffers from the position dependency problem since a smartphone may be placed in any pockets or hands. In order to overcome these problems, this paper proposes an effective activity recognition method which is less dependent with both specific users and specific positions of the smartphone. Based on the proposed method, we implement a real-time activity recognition system working on an Android smartphone. Throughout some experiments with 6642 examples collected from different users and different positions, we investigate the performance of our activity recognition system.

Efficient Processing using Static Validity Circle for Continuous Skyline Queries (연속적인 스카이라인 질의의 정적 유효 영역을 이용한 효율적인 처리)

  • Li, Zhong-He;Park, Young-Bae
    • Journal of KIISE:Databases
    • /
    • v.33 no.6
    • /
    • pp.631-643
    • /
    • 2006
  • Moving objects in a mobile environment to change their position based on the change of time require a query with their position as a basis. Efficient Regional Decision for Continuous Skyline Queries requires objectively pre-calculating the OSR(Optimal Skyline Region) regardless of the speed and direction of the moving objects. It proposes techniques to reduce the frequency of continuous queries by choosing a VCircle(Validity Circle) as safe location which has radius of the distance to the closest region with position on the moving object at center. But, a VCircle's area varies based on the Moving object's position from first marked time of continuous query. Therefore, the frequency of its continuous query is variable and also when the object moves inside of OSR, query can re-occur frequently In this paper, we suggest a technique of selecting an IVCircle(Interior Validity Circle) in a Skyline Region as the static Safe Region using the characteristics of the OSR. An Interior IVCircle can be calculated in advance when the OSR is decided. Our experiment shows that the frequency of using IVcircle as safe region reduced than that of using VCircle as safe region by 52.55%.

Combination Analysis of Optical Tracking System Design Variables for Unknown Space Objects Using Effectiveness Analysis Simulation (효과분석 시뮬레이션을 이용한 미지 우주물체 광학 추적 시스템 설계 변수 조합 분석)

  • Hyun, Chul;Lee, Sangwook;Lee, Hojin;Park, Seung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.9
    • /
    • pp.1312-1319
    • /
    • 2022
  • This paper defines an effectiveness index for optical continuous observation of unknown space objects and presents a range of design variables combinations that can satisfy the effectiveness index from a telescope/mount control system perspective using integrated simulation. The overall system-level simulation was implemented and the tracking performance was analyzed by considering design variables such as target position prediction and frame rate, image processing time and measurement error, target trajectory characteristics, and maneuver performance of mount gimbal. As a result of the analysis, it was confirmed that the continuous tracking performance of the optical observation system is dependent on the combination of frame rate and mount maneuver performance. In a situation where an optical observation system is designed or a similar system is implemented using COTS, an appropriate combination of parameters between design variables can be found through effectiveness analysis simulation as in this study.

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.