• Title/Summary/Keyword: portal

Search Result 2,062, Processing Time 0.026 seconds

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.

Arthroscopic Treatment for the Pigmented Villonodular Synovitis in the Knee (슬관절에 발생한 색소 융모 결절성 활액막염의 관절경적 치료)

  • Bae, Dae-Kyung;Cho, Nam-Su
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.22-26
    • /
    • 2001
  • Purpose : To confirm the efficacy of arthroscopic synovectomy fur the pigmented villonodular synovitis in the knee. Materials and Methods : Between October 1996 and February 2000, the arthroscopic synovectomy had been performed in six patients(six knee joints), whose diagnoses were confirmed by pathologist. All patients complained of painful swelling in involved knee and four of the six patients had trauma history. There were three male and three female patients. Average age was 35.8 years ranging from 16 to 67 years. Follow up period was average 22.7 months(range, $13\~53$ months). Results : According to arthroscopic findings, there were three localized forms and three diffuse forms. At their last follow-up examinations, all patients had improvement in pain, swelling and range of motion and there was no evidence of recurrence. Conclusion : Complete arthroscopic excision is the definitive treatment for localized pigmented villonodular synovitis and meticulous arthroscopic excision through all portals including posterior portal can be considered as a valid alternative to traditional open synovectomy for the patients with diffuse pigmented villonodular synovitis.

  • PDF

Analyzing the Issue Life Cycle by Mapping Inter-Period Issues (기간별 이슈 매핑을 통한 이슈 생명주기 분석 방법론)

  • Lim, Myungsu;Kim, Namgyu
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.4
    • /
    • pp.25-41
    • /
    • 2014
  • Recently, the number of social media users has increased rapidly because of the prevalence of smart devices. As a result, the amount of real-time data has been increasing exponentially, which, in turn, is generating more interest in using such data to create added value. For instance, several attempts are being made to analyze the relevant search keywords that are frequently used on new portal sites and the words that are regularly mentioned on various social media in order to identify social issues. The technique of "topic analysis" is employed in order to identify topics and themes from a large amount of text documents. As one of the most prevalent applications of topic analysis, the technique of issue tracking investigates changes in the social issues that are identified through topic analysis. Currently, traditional issue tracking is conducted by identifying the main topics of documents that cover an entire period at the same time and analyzing the occurrence of each topic by the period of occurrence. However, this traditional issue tracking approach has two limitations. First, when a new period is included, topic analysis must be repeated for all the documents of the entire period, rather than being conducted only on the new documents of the added period. This creates practical limitations in the form of significant time and cost burdens. Therefore, this traditional approach is difficult to apply in most applications that need to perform an analysis on the additional period. Second, the issue is not only generated and terminated constantly, but also one issue can sometimes be distributed into several issues or multiple issues can be integrated into one single issue. In other words, each issue is characterized by a life cycle that consists of the stages of creation, transition (merging and segmentation), and termination. The existing issue tracking methods do not address the connection and effect relationship between these issues. The purpose of this study is to overcome the two limitations of the existing issue tracking method, one being the limitation regarding the analysis method and the other being the limitation involving the lack of consideration of the changeability of the issues. Let us assume that we perform multiple topic analysis for each multiple period. Then it is essential to map issues of different periods in order to trace trend of issues. However, it is not easy to discover connection between issues of different periods because the issues derived for each period mutually contain heterogeneity. In this study, to overcome these limitations without having to analyze the entire period's documents simultaneously, the analysis can be performed independently for each period. In addition, we performed issue mapping to link the identified issues of each period. An integrated approach on each details period was presented, and the issue flow of the entire integrated period was depicted in this study. Thus, as the entire process of the issue life cycle, including the stages of creation, transition (merging and segmentation), and extinction, is identified and examined systematically, the changeability of the issues was analyzed in this study. The proposed methodology is highly efficient in terms of time and cost, as it sufficiently considered the changeability of the issues. Further, the results of this study can be used to adapt the methodology to a practical situation. By applying the proposed methodology to actual Internet news, the potential practical applications of the proposed methodology are analyzed. Consequently, the proposed methodology was able to extend the period of the analysis and it could follow the course of progress of each issue's life cycle. Further, this methodology can facilitate a clearer understanding of complex social phenomena using topic analysis.

Stereotactic Radiotherapy by 6MV Linear Accelerator (6MV 선형가속기를 이용한 정위다방향 단일 고선량 조사)

  • Oho, Yoon-Kyeong;Kim, Mi-Hee;Gil, Hak-Jun;Yoon, Sei-Chul;Lee, Jae-Moon;Choi, Kyu-Ho;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Moon-Chan;Kang, Joon-Ki;Song, Jin-Un
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.269-276
    • /
    • 1988
  • Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngiom (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be peformed safely with a radiation dose of 12-30 Gy. So this nonivasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT.

  • PDF

Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker (인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고)

  • Chae, Seung-Hoon;Park, Jang-Pil;Lee, Yang-Hoon;Yoo, Suk-Hyun;Seong, Won-Mo;Kim, Kyu-Bo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • Purpose: In this study, we considerate our radiation therapy process for the breast cancer patient implanted a pacemaker applying the machine movement surgery, shielding, beam selection. Materials and Methods: We perform radiation therapy to a 54 years old, breast cancer patient implanted a pacemaker. The patient underwent a surgery to move the position of a pacemaker to right side breast after consultation with cardiology department. Prescribed dose was 5,040 cGy and daily dose 180 cGy for 28 fractions. The 10 MV photon energy, field size 0/$9.5{\times}20$ cm, half beam and opposing portal irradiation are used. To find out appropriate thickness of shielding board, we carried out an experiment using a solid water phantom ($30{\times}30{\times}7$ cm), a Farmer-type chamber (TN30013, PTW, Germany) and a shielding board (Pb $28{\times}27{\times}0.1$ cm). We calculated expected absorbed dose to te pacemaker with absorb ratio and shielding ratio. In the PTP system (Eclipse, Varian, USA), we figured out how much radiation would be absorbed to the machine with and without shielding. First day of the radiation therapy, we measured head scatter to the pacemaker with MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada). Results: In the phantom measurement, we found out appropriate thickness was 2 mm of shielding board. In the RTP, when using 2 mm shielding the pacemaker will be absorbed 11.5~38.2 cGy and DVH is 77.3 cGy. In the first day of the therapy, 4.3 cGy was measured so 120.4 cGy was calculated during total therapy. The patient was free from any side effects, and the machine also normally functioned. Conclusion: As the report of association which have public confidence became superannuated, there is lack of data about new machine. We believe that radiation therapy to thiese kind of patients could be done successfully with co-operation, patient-suitable planning, accurate QA, frequent in-vivo dosimetry and monitoring.

  • PDF

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Features of Korean Webtoons through the Statistical Analysis (웹툰 통계 분석을 통한 한국 웹툰의 특징)

  • Yoon, Ki-Heon;Jung, Kiu-Ha;Choi, In-Soo;Choi, Hae-Sol
    • Cartoon and Animation Studies
    • /
    • s.38
    • /
    • pp.177-194
    • /
    • 2015
  • This study that had been conducted two months by a research team of Pusan National University at the request of Korea Manwha Contents Agency in Dec. 2013 is about the statistical analysis on 'Korean Webtoon DB and its Flow Report' which resulted from the complete survey of Korean webtoons which had been published with payment in official media from early 2000 to 2013. Webtoon which means the cartoons published on web has become a typical type of Korean cartoons and has developed into a main industry since 2000s when traditional published cartoons had declined and social environments had changed. Today, it represents cultural contents in Korea. This study collected the webtoons officially published in media with payment, among Korean webtoons having been published from the early 2000s to Jan. Based on the collected data, it analyzed the general characteristics of webtoons, including cartoonists, the number of cartoons, distribution chart of each media, genre, and publication cycle. According to the data analysis and statistics, a great deal of Korean webtoons are still published in main portal websites, but their platform is being diversified and a webtoon's publication cycle tends to be shortened. In terms of genre, traditional popular genres, such as drama, comic, fantasy, and action, are still popular, and the genres of history, sports, and food are on the rise along with a social trend. Regarding webtoon application, such events as relay webtoon and brand webtoon, and a new type of webtoon featuring PPL commercialism appear. Such phenomena can realize the common profits of cartoonists, media, and ordering bodies, and are various trials to test the possibility of webtoons. In addition, what needs to pay attention on in the expansion of webtoons is increasing webtoons for adults. The study subjects are the webtoons published with payment, excluding free webtoons. However, this study failed to collect the webtoons published on the online websites already closed, and the lost information on cartoonists and their lost webtoons, and it is necessary to conduct a complete survey on all webtoons including free ones. Despite the limitations, this study is meaningful in the points that it categorized and analyzed Korean webtoons accoridng to official media, webtoons, cartoonists, and genres and that it provided a fundamental material to understand the current conditions of webtoons. It is expected that this study will be able to contribute to activating more research on webtoons and producing more supplementary data which will be used for the Korean cartoon industry and academia.

Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) - (내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) -)

  • Ahn, Jin-Hwan;Ha, Chul-Won;Kim, Ho;Kim, Sung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 1999
  • Purpose : The importance of meniscal repair is well recognized. But transeciton of the posterior horn of the medial meniscus at the posterior tibial attachment is rarely documented and known irreparable. We experienced 9 cases of transection, and present clinical features and pull out suture technique. Methods and Materials : There were 9cases of transection of the posterior horn of medial meniscus from September 1998 to July 1999 in our hospital. Age was 59.3 years in average and ranged from 38 to 70years. Clinical features and MRI made diagnosis in all cases. We confirmed the diagnosis with arthroscopy and repaired the transection with pullout suture technique. Clinical features : Transection of the posterior horn of the medial meniscus at the posterior tibia attachment occurred frequently in middle aged people. They complained posterior knee pain, but they have no history of definitive trauma. Characteristically they had difficulty in full flexion of the knee and in having a squatting position. MRI is very important in diagnosis of transection, especially in coronal view, there is separation of the posterior horn of the meniscus from the posterior tibial attachment. Surgical technique : Pullout suture technique includes debridement of fibrous or scar tissue, exposure of the subchondral bone of the posterior tibial attachment site, suture the transected end of the meniscus with PDS suture, bone tunnel formation from the anteromedial aspect of the proximal tibia, insertion of wire loop through the tibia tunnel, pull the PDS suture through the tibia tunnel out of the joint and stabilize the PDS with post-tie technique to the proximal tibia. Conclusion : Transection of the posterior horn of the medial meniscus at the posterior tibial attachment is not common clinically and rarely documented. Clinical features and MRI are very important in diagnosis of this type tear. Arthroscopic pullout sutures is useful for treatment of this type tear of the meniscus.

  • PDF

A Study on Intertextuality in <2013 Home of the Legends> (연작 웹툰 《2013 전설의 고향》에 나타나는 상호텍스트성 연구)

  • Yang, Hyelim
    • Cartoon and Animation Studies
    • /
    • s.34
    • /
    • pp.293-316
    • /
    • 2014
  • (傳說의 故鄕) is a broadcast play as one-act play series based on Korean legends and folktales. It was first aired in 1977 from KBS and there has been borrowed from this play in a variety of genres such as books and movies as the name of this series securing its popularity and awareness of the public. In this context, this is a representative work for Korean horror genre. Recently, for example, a series webtoon <2013 Home of the Legends> is published on one of the main portal websites, NAVER from July, 2013. This webtoon is main subject of this study. The purpose of this study is to discuss how the genre characteristics of Korean horror in TV serial play transmitted and changed in series webtoon <2013 Home of the Legends>. TV serial play is a representative narrative based on Korean folktales, trying to change its narrative in the range of undestroyed folktale basic move with combining the original motifs. Serial webtoon <2013 Home of the Legends>, however, deconstructs this combination motif in folktale form and leads to new move in narrative. For Korean users accustomed to Korean folktale form as the architext, this will be expected as reversal and make catharsis. Meanwhile, the deconstruction of combination motif leads to extinction of its cause-and-effect, which consists the axis of original narrative form, with resulting powerless theme, good overcoming evil and punitive justice. The aspects of changes in <2013 Home of the Legends> represent new orientation of Korean horror.

Contralateral Breast Doses Depending on Treatment Set-up Positions for Left-sided Breast Tangential Irradiation (좌측 유방암 환자의 방사선 치료 시 환자자세에 따른 반대편 유방의 산란선량 측정)

  • Joo, Chan Seong;Park, Su Yeon;Kim, JongSik;Choi, Byeong Gi;Chung, Yoonsun;Park, Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Purpose : To evaluate Contralateral Breast Doses with Supine and Prone Positions for tangential Irradiation techniques for left-sided breast Cancer Materials and Methods : We performed measurements for contralateral doses using Human Phantom at each other three plans (conventional technique, Field-in-Field, IMRT, with prescription of 50 Gy/25fx). For the measurement of contralateral doses we used Glass dosimeters on the 4 points of Human Phantom surface (0 mm, 10 mm, 30 mm, 50 mm). For the position check at every measurements, we had taken portal images using EPID and denoted the incident points on the human phantom for checking the constancy of incident points. Results : The contralateral doses in supine position showed a little higher doses than those in prone position. In the planning study, contralateral doses in the prone position increased mean doses of 1.2% to 1.8% at each positions while those in the supine positions showed mean dose decreases of 0.8% to 0.9%. The measurements using glass dosimeters resulted in dose increases (mean: 2.7%, maximum: 4% of the prescribed dose) in the prone position. In addition, the delivery techniques of Field-in-field and IMRT showed mean doses of 3% higher than conventional technique. Conclusion : We evaluated contralateral breast doses depending on different positions of supine and prone for tangential irradiations. For the phantom simulation of set-up variation effects on contralateral dose evaluation, although we used humanoid phantom for planning and measurements comparisons, it would be more or less worse set-up constancy in a real patient. Therefore, more careful selection of determination of patient set-up for the breast tangential irradiation, especially in the left-sided breast, should be considered for unwanted dose increases to left lung and heart. In conclusion, intensive patient monitoring and improved patient set-up verification efforts should be necessary for the application of prone position for tangential irradiation of left-sided breast cancer.

  • PDF