• 제목/요약/키워드: pore water pressure dissipation test

검색결과 27건 처리시간 0.027초

피에조콘 소산결과와 압축지수의 상관관계 (Correlation of Piezocone Dissipation Results and Compression Index)

  • 박영환;강병준;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1204-1211
    • /
    • 2008
  • Compression index is one of the important characteristic numbers in soft soil engineering. Since 1940's, many researchers have suggested various practical solutions to define the compression index of clay using other soil properties. But, these results are only can give us an outline of soft soil behavior. In this study, the relationships between pore water pressure dissipation test results and compression index were suggested using comparison results of both tests. This relationships are based on basic concept of consolidation phenomena, essential difference between pore water pressure dissipation test and consolidation test, and disagreements between theoretical time factor and real time factor. To identify proportional factor of proposed equation, Geotechnical investigation results of Kwang-Yang(KY) site and Busan New Port(BN) site were used. The proportional factor was 0.0031 from 20 to 50% of consolidation rate where correlation parameter($R^2$) is 0.9051.

  • PDF

Effects of excess pore pressure dissipation on liquefaction-induced ground deformation in 1-g shaking table test

  • Wang, B.;Zen, K.;Chen, G.Q.;Kasama, K.
    • Geomechanics and Engineering
    • /
    • 제4권2호
    • /
    • pp.91-103
    • /
    • 2012
  • Focusing on the effect of excess pore pressure dissipation on liquefaction-induced ground deformation, a series of 1-g shaking table tests were conducted in a rigid soil container by use of saturated Toyoura sand, the relative density of which was 20-60%. These tests were subjected to the sinusoidal base shaking with step increased accelerations: 100, 200, 300 and 400 Gals for 2-4 seconds. Shaking table tests were done using either water or polymer fluid with more viscous than water, thus varying the sand permeability of model tests. Excess pore pressures, accelerations, settlements and lateral deformations were measured in each test. Test results are presented in this paper and the effect of sand permeability on liquefaction and liquefaction-induced ground deformation was discussed in detail.

액상화 지반에 대한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests on Liquefied Sand Grounds)

  • 김성렬;황재익;;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.

  • PDF

실내모형실험을 통한 연직배수재 타설에 의한 스미어존의 평가 (An Estimation of Smear Zone Induced by Vertical Drain Construction Based on the Laboratory Model test)

  • 김홍택;한연진;김승욱;황정순
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.279-282
    • /
    • 2007
  • When ground disturbance takes place due to vertical drain construction through mandrel penetration, that affects excess pore water pressure dissipation time because of soft clay coefficient of permeability decreasing. Eventually, consolidation time is influenced. In this research, we measure process of excess pore water pressure dissipation before and after each other different shape's mandrel penetration through model test, and calculates range of smear zone, coefficient of permeability and horizontal coefficient of consolidation after model test. Using of test result, we grasp a degree of drainage ability drop resulting from vertical drain construction.

  • PDF

Numerical analysis of vertical drains accelerated consolidation considering combined soil disturbance and visco-plastic behaviour

  • Azari, Babak;Fatahi, Behzad;Khabbaz, Hadi
    • Geomechanics and Engineering
    • /
    • 제8권2호
    • /
    • pp.187-220
    • /
    • 2015
  • Soil disturbance induced by installation of mandrel driven vertical drains decreases the in situ horizontal hydraulic conductivity of the soil in the vicinity of the drains, decelerating the consolidation rate. According to available literature, several different profiles for the hydraulic conductivity variation with the radial distance from the vertical drain, influencing the excess pore water pressure dissipation rate, have been identified. In addition, it is well known that the visco-plastic properties of the soil also influence the excess pore water pressure dissipation rate and consequently the settlement rate. In this study, a numerical solution adopting an elastic visco-plastic model with nonlinear creep function incorporated in the consolidation equations has been developed to investigate the effects of disturbed zone properties on the time dependent behaviour of soft soil deposits improved with vertical drains and preloading. The employed elastic visco-plastic model is based on the framework of the modified Cam-Clay model capturing soil creep during excess pore water pressure dissipation. Besides, nonlinear variations of creep coefficient with stress and time and permeability variations during the consolidation process are considered. The predicted results have been compared with V$\ddot{a}$sby test fill measurements. According to the results, different variations of the hydraulic conductivity profile in the disturbed zone result in varying excess pore water pressure dissipation rate and consequently varying the effective vertical stresses in the soil profile. Thus, the creep coefficient and the creep strain limit are notably influenced resulting in significant changes in the predicted settlement rate.

상사법칙 검증을 위한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests for Similitude Laws)

  • 김성렬;황재익;김명모
    • 한국지반공학회논문집
    • /
    • 제22권5호
    • /
    • pp.59-67
    • /
    • 2006
  • 동일한 흙으로 조성된 모형지반에 대하여 1-g 모형실험과 원심모형실험을 수행하고 그 결과를 비교하였다. 원형지반은 10m 두께의 수평하고 느슨한 포화 사질토 지반으로 가정하였다. 1-g 모형실험은 1/20 축소모형, 원심모형실험은 1/40 축소모형을 이용하였다. 원심모형실험의 경우 점성유체를 사용하여 동적시간에 대한 상사비와 과잉간극수압소산시간에 대한 상사비가 동일하도록 하였다. 원심모형실험의 계측결과는 원형지반의 거동으로 가정하였다. 그리고, 1-g모형실험에 정상상태개념 및 두 가지 시간상사비 등을 적용하여 원형지반의 거동을 모사하고자 하였다. 동일한 위치에서의 과잉간극수압, 지반가속도 그리고 지표 침하량 등을 계측하여 비교하였다. 실험결과 지반의 투수계수가 작아서 진동 중 과잉간극수압 소산의 영향이 작고, 소산시간상사비를 적절하게 결정하면 1-g 모형실험으로부터 원형지반의 과잉간극수압 거동을 모사할 수 있는 것으로 나타났다.

피에조콘 시험의 유한요소 해석 II (Finite Element Analysis of Piezocone Test II)

  • 김대규;김낙경
    • 한국지반공학회논문집
    • /
    • 제16권4호
    • /
    • pp.191-199
    • /
    • 2000
  • 본 연구에서는 피에조콘 시험의 유한요소해석을 수행하였다. 이를 위하여 점탄소성 bounding surface 모델, 가상일의 방정식(virtual work equation) 및 theory of mixtures를 Updated Lagrangian reference frame에서 formulation하였다. 결과적으로 구성된 유한요소 formulation을 컴퓨터 프로그래밍 하였으며 유한요소해석에서 얻은 콘 저항치, 과잉간극수압 및 간극수압소산 등의 결과를 실험치와 비교 분석하였으며 피에조콘 주변의 응력, 변형율 및 과잉간극수압의 contour를 유한요소해석에서 구하여 이를 고찰하였다. 비등방성 및 점성이 추가된 구성모델을 사용함으로서 응력의 비등방성 및 관입속도를 효과적으로 simulation할 수 있었다. 유한요소 Formulation 과정은 'I' 결과는 'II'에서 설명된다.

  • PDF

피에조 콘 소산시험을 이용한 압밀계수 추정시 이론해의 선택 및 현장지반의 압밀도 평가

  • 이승래;김영상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1998년도 지반조사위원회 봄 학술세미나
    • /
    • pp.37-46
    • /
    • 1998
  • Several researchers have developed a number of theoretical time factors to determine the coefficient of consolidation by biezocone excess pore water dissipation test in soft clay deposits. However, depending on the assumptions and analytical techniques, the estimated coefficient of consolidation could be in a considerably wide range even for a specific degree of consolidation. These solutions are obtained from an initial excess porewater pressure distribution which can be determined from. either the cavity expansion theory or the strain path method. The 야ssipation of the initial excess porelvater pressure has been usally simulated by means of linear-uncoupled consolidation analysis and then the dissipation curve is normalized by the initial excess porewater pressure for easy use. However. since there is no guidelines or rules on which method gives the best solution for obtaining the coefficient of consolidation from the dissipation curve, the final selection was only based on engineer's extrience and Judgements. Thus, such an arbitrary selection might be inappropriate for a specific site to characterize the consolidation behavior. In this paper, we reviewed various theoretical time factors and, based on this consideration, we mentioned needs for researches in selecting a specific solution that is compatible for Korean clays. Also we listed some source of errors that can be encountered in the procedure of dissipation analysis.

  • PDF

피에조 콘과 딜라토메터 시험을 이용한 연약지반의 현장특성 비교 (Comparison of Tn-situ Characteristics of Soft Deposits Using Piezocone and Dilatometer)

  • 김영상;이승래;김동수
    • 한국지반공학회지:지반
    • /
    • 제14권6호
    • /
    • pp.45-56
    • /
    • 1998
  • 대상 연약지반의 적절한 개량기술 선택과 개량 효과들을 평가, 관리하기 위해서는 현장 연약 점토지반 특성을 정확히 평가할 수 있는 적절한 현장 시험기법의 적용이 필수적이다. 본 논문에서는 여러 현장시험 방법 중에 경제적이면서도 효과적인 것으로 알려져 국내에서 그 수요가 증가하고 있는 피에조 콘(piezocone)과 딜라토메터(dilatometer)를 이용하여 연약지반의 현장 물성을 평가하고 비교하였다. 연구결과 두 장비 모두 유사한 흙 분류 결과를 제공하였으나. 특히 간극수압으로부터 도출한 흙 분류 결과가 연약점토층 사이에 실트나 모래층 들이 산재한 우리나라 실정에 보다 적절하며 일관성 있는 결과를 주는 것으로 평가되었다. 점토층의 비배수 전단강도는 피에조 콘의 경우 간극수압과 선단저항력으로부터 도출된 간들이 유사하였고 딜라토메터로부터 추정된 비배수 전단강도는 피에조 콘의 두 관측 값으로 유추된 결과들의 평균간에 근접한 것으로 평가되었다. 그리고 실트 또는 모래층이 산재하는 경우 연약지반의 압밀특성을 평가하기 위해서는 관입과정에서 유발되는 소산효과를 고려한 이론적 시간계수가 보다 적절한 것으로 평가된다.

  • PDF

피압에 따른 연약지반의 압밀 거동 (Consolidation Characteristics of Soft Ground with Artesian Pressure)

  • 윤대호;김재홍;김윤태
    • 한국지반환경공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.31-39
    • /
    • 2016
  • 일반적으로 고함수비를 가진 연약지반의 경우 압밀 촉진을 원활히 하기 위하여 연직배수재를 주로 사용하고 있다. 부산 점토는 대심도 연약지반 아래에 존재하는 모래 및 자갈 대수층에 피압이 관측되었다. 그러나 연직배수재가 설치된 연약지반에 피압이 미치는 영향에 대한 조사나 연구는 미미한 실정이다. 따라서 본 논문에서는 연직배수재가 설치된 부산 낙동강 하구 연약지반에 피압의 작용 유 무에 따른 압밀 거동을 조사하기 위해 일차원 대형 컬럼 장치를 제작하여 점토지반의 압밀 거동 실험을 수행하였다. 실험 결과 최종 침하량은 피압이 작용하는 지반이 피압이 작용하지 않는 지반보다 더 크게 나타났다. 이는 피압의 상향침투로 인해 점토층의 유효응력이 감소하여 나타난 결과로 판단된다. 또한 피압이 작용하는 지반의 경우 과잉간극수압이 완전 소산되지 않고 잔류하는 것으로 나타났으며, 비배수 전단강도는 피압이 작용하지 않는 지반에 비해 상대적으로 낮은 값을 나타내었다.