• Title/Summary/Keyword: pore volume test

Search Result 116, Processing Time 0.023 seconds

Laboratory Test for the Performance of Grouting under Hydrostatic Pressure (정수압을 고려한 그라우팅의 성능에 대한 실험적 연구)

  • Jun, Kyoung-Jea;Oh, Myounghak;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.49-58
    • /
    • 2017
  • Grouting for soil improvement has generally been applied to the depth over water table. Recently, it is needed to develop the grouting technique for soils under greater static water pressure or greater overburden pressure in constructions such as deep excavation or harbour deepening. In this study, a laboratory apparatus was developed to control the injection pressure, load pressure, and hydrostatic pressure. A series of experiments were performed with various degrees of hydrostatic pressure using the developed equipment. As a result, injected volume increase as injection pressure increase, while the volume significantly decreased under hydrostatic pressure. Larger volume of grout bulb was shown in soils with larger granular and pore size based on the comparison result of volume changes with respect to the amount of grouting injection.

An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type (무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구)

  • 김영삼;양승도;유재강;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.31-36
    • /
    • 2002
  • Recently, more interests in surface treatment of structure with water repellent agent are steadily increased, But, investigation of its properties such as protection, durability, morphology of micro structure is not sufficient. Therefore, This paper is aimed for the investigation of water repellent property and change of morphology of micro pores in mortar that is treated by water repellent agent(Inorganic polymer based material). Water repellent property, water absorption coefficient, air permeability, porosity and the observation of micro structure was investigated in different water repellent agent type. The test results indicated that water repellent treated mortar showed low absorption coefficient and air permeability(breathing effect). This is why inorganic polymer is coated at the wall of capillary and micro pores, also, the volume of micro pore is reduced without the change of morphology in micro structure.

  • PDF

Adsorption Characteristics of BTEX on Dust Collecting Electrode Coated with Activated Carbon (활성탄으로 코팅된 집진전극의 BTEX 흡착특성)

  • Nam, Sangchul;Kim, Hyun Jung;Kim, Kwang Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.773-779
    • /
    • 2013
  • This study was performed to provide the basic data for the function of BTEX removal for compact electrostatic precipitator which are applicable to indoor environment (or closed spaces). For this purpose, the adsorption equilibrium test was conducted for BTEX of activated carbon sheet (ACS) and activated carbon (AC), and the adsorption characteristics of AC and ACS were evaluated using the Langmuir constant which was obtained from the adsorption characteristics, adsorption capacity and regression calculation. The surface area and adsorption pore volume of ACS reduced by 70% and 86%, respectively, as compared to those of AC, and the adsorption capacities of BTEX also showed a similar level. Thus, it is considered that ACS applied electrostatic precipitator is able to remove dust and BTEX simultaneously.

Mechanical and Electrical Properties of Hydrate-bearing Sediments (하이드레이트 함유 퇴적물의 역학적 성질 및 지구물리 특성)

  • Lee, J.Y.;Francisca, F.;Santamarina, J.C.;Ruppel, C.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.594-596
    • /
    • 2007
  • Using an oedometer cell instrumented to measure the evolution of electromagnetic properties, small strain stiffness, and temperature, we conducted consolidation tests on four types of sediments. The tested specimens include sediments with different gas hydrate saturation at four stages of loading. The test results show that the electromagnetic and mechanical properties of hydrate-bearing marine sediments are governed by the vertical effective stress, stress history, porosity, hydrate saturation, fabric, ionic concentration of the pore fluid, and temperature. The results also show that permittivity and electrical conductivity data can be combined to estimate hydrate volume fraction in laboratory sediments, methodology that might eventually be extended for estimation of hydrate concentrations in field settings.

  • PDF

Study I of Catalyst Aging (촉매의 열화에 관한 연구 I)

  • 손건석;이지연;이귀영;최병철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.86-94
    • /
    • 1997
  • Quick aging of catalysts has done with IAE(Institute for advanced engineering) AGING MODE suggested by IAE. To estimate the effects of number of aging cycle, temperature and $H_2O$, characteristics of surfaces, mechanical properties and weibull modulus were estimated. Also, the conversion efficiency of aged catalysts was evaluated with model gas bench test. The area of surface and pore volume were decreased according to the number of aging cycle. The precious metal which is well dispersed in fresh state was sintered and agglomerated with aging. The mechanical of deactivation and sintering of catalysts are discussed on the basis of mechanical tests. The conversion efficiency was decreased with the repeats of aging. Especially, the existence of $H_2O$ in supply gas had a main role in catalyst deactivation withy high temperature.

  • PDF

Bond Strength and Tensile Strength of Polymer-Modified Mortar Using Styrene and Butyl Acrylate (St/BA를 혼입한 폴리머 시멘트 모르타르의 부착강도 및 인장강도 특성)

  • You, Kipyo;Hyung, Wongil
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.820-826
    • /
    • 2014
  • The objective of this study is to find the relationship between the tensile strength of the polymer film and the bond strength and tensile strength of the polymer-modified mortar using styrene (St) and butyl acrylate (BA), and porosity. In the test results, the bond strength and tensile strength of the polymer-modified mortar increased with increases in the tensile strength of polymer film and the fine pore volume.

Plastic Behaviro of Two Phase Intermetallic Compounds Based on $Li_2$-type$(Ai, Cr)_3$/Ti ($Li_2$$(Ai, Cr)_3$/Ti기 2상 금속간화합물의 소성거동)

  • Park, Jeong-Yong;O, Myeong-Hun;Wi, Dang-Mun;Miura, S.;Mishima, Y.
    • Korean Journal of Materials Research
    • /
    • v.4 no.8
    • /
    • pp.906-914
    • /
    • 1994
  • Plastic behavior of two-phase intermetallic compounds based on $LI_{2}$-type $(Al, Cr)_3$ Ti was investigated using compression test at R.T. and 77K. $LI_{2}$ single phase alloys and two-phase alloys consisting of mainly $LI_{2}$ phase and a few or 20% second phases were selected from AI-Ti-Cr phase diagram. In general, compared with Llz single phase, two-phase alloys consisting of 20% second phase showed relatively high yield strength and poor ductility. Among the alloys, however, AI-21Ti-23Cr alloy consisting of 20% $Cr_{2}Al$ phase showed available ductility as well as high yield strength. Plastic behavior of $LI_{2}$ single phase alloys and two-phase alloys consisting of a few% $Cr_{2}Al$ was also investigated. Homogenization of arc melted ingots substantially reduced the amount of second phases but introduced extensive pore. When Cr content increased in $Ll_{2}$ single phase alloys after the homogenization, the volume fraction of pore in the alloys decreased, and no residual pore was observed in two-phase alloys consisting of a few% $Cr_{2}Al$ phase. Environmental effect on the ductility of the alloys was investigated using compression test at different strain rates($1.2 \times 10^{-4}/s$ and $1.2 \times 10^{-2}/s$). Environmental embrittlement was least significant in A1-25Ti-10Cr alloy consisting of LIZ single phase among the alloys tested in this study. However, based on the combined estimation of the pore formation, environmental embrittlement and ingot cast structure, AI-21Ti-23Cr alloy consisting of 20% $Cr_{2}Al$ as the second phase is expected to show the best tensile elongation behavior.

  • PDF

The Effect of Air Injection Quantity on Stabilization of Screened Soil in Aerobic Bioreactor Landfill (호기성 Bioreactor 매립지에 있어서 공기주입량이 선별토사의 안정화에 미치는 영향)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Nack-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.104-109
    • /
    • 2004
  • In this study, we stabilized the screened soil from landfills by using aerobic bioreactor and evaluated aerobic decomposition of it. Four lab-scale bioreactors (anaerobic and 1 PV/day aeration, 5 PV/day aeration, 10 PV/day aeration) filled with screened soil were operated to investigate the effect of air injection quantity on stabilization of screened soil. In case of aerobic bioreactors, the decomposition of organics in screened soil was higher than anaerobic bioreactor. According to the results of landfill gas and soil respiration test, the air injection quantity of 5 PV/day was most efficient in stabilization of screened soil.

  • PDF

Modelling of Permeability Reduction of Soil Filters due to Clogging (흙 필터재의 폐색으로 인한 투수성 저하 모델 개발)

  • ;;Reddi, Lakshmi.N
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.271-278
    • /
    • 1999
  • Soil filters are commonly used to protect the soil structures from eroding and piping. When filters are clogged by fine particles which are progressively accumulated, these may lead to buildup of excessive pore pressures also leading to instability in subsurface infrastructure. A filter in the backfill of a retaining wall, a filter adjacent to the lining of a tunnel, or a filter in the bottom of an earth dam can be clogged by transported fine particles. This causes reduction in the permeability, which in turn may lead to intolerable decreases in their drainage capacity. In this thesis, the extent of this reduction is addressed using results from both experimental and theoretical investigations. In the experimental phase, the permeability reduction of a filter is monitored when an influent of constant concentration flows into the filter (uncoupled test), and when the water flow through the soil-filter system to simulate an in-situ condition (coupled test), respectively. The results of coupled and uncoupled test are compared with among others. In the theoretical phase of the investigation, a representative elemental volume of the soil filter was modeled as an ensemble of capillary tubes and the permeability reduction due to physical clogging was simulated using basic principles of flow in cylindrical tubes. In general, it was found that the permeability was reduced by at least one order of magnitude, and that the results from the uncoupled test and theoretical investigations were in good agreement. It is observed that the amount of deposited particles of the coupled test matches fairly well with that of the uncoupled test, which indicates that the prediction of permeability reduction is possible by preforming the uncoupled test instead of the coupled test, and/or by utilizing the theoretical model.

  • PDF

Study on the Improvement for Measuring Procedures of Volumetric Pressure Plate Extractor (체적압력판추출기의 측정법 개선에 관한 연구)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.185-191
    • /
    • 2010
  • Volumetric pressure plate extractor (VPPE) can be used for measurement of the soil-water characteristic curve in the laboratory using the axis-translation technique. The volume of extracted water from the soil specimen in VPPE can be measured continuously during the test without stoppage of air pressure for the measurements. However, the water volume measurement in VPPE using an air trap, a ballast tube, a burette, and a vacuum device so as to maintain a constant pore-water pressure in the soil specimen, is quite complicated and tedious. In order to improve the measuring problems of VPPE, a modified volumetric pressure plate extractor (MVPPE) was developed and tested on residual soil specimens. In addition, the modified apparatus can measure the volume of the extracted water using both Method A and Method B of ASTM D 6836-02 depending on the range of matric suction. Measuring principles and the improvements of MVPPE and typical results obtained from the tests are discussed in the paper.