• Title/Summary/Keyword: porcelain fracture

Search Result 109, Processing Time 0.022 seconds

Effects of Various Acid Etching Methods on the Shear Bond Strength between Iithium Disilicate Ceramic and Composite Resin (다양한 산처리 방법이 lithium Disilicate 도재와 복합레진간의 전단결합강도에 미치는 영향)

  • Kang, Dae-Hyun;Bok, Won-Mi;Song, Jin-Won;Song, Kwang-Yeob;Ahn, Seung-Ggeun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.149-159
    • /
    • 2006
  • Statement of problem. Porcelain repair mainly involves replacement with composite resin, but the bond strength between composite resin and all-ceramic coping materials has not been studies extensively. Purpose. The objective of this study was to investigate the influence of composite resin and ceramic etching pattern on shear bond strength of Empress2 ceramic and observe the change of microstructure of ceramic according to etching methods. Material and methods. Eighty-five cylinder shape ceramic specimens (diameter 5mm, IPS Empress 2 core materials) embeded by acrylic resin were used for this study. The ceramic were specimens divided into sixteen experimental groups with 5 specimens in each group and were etched with phosphoric acid(37%, 65%) & hydrofluoric acid (4%, 9%) according to different etching times(30s, 60s, 120s 180s). All etched ceramic surfaces were examined morphologically using SEM(scanning electron microscopy). Etched surfaces of ceramic specimens were coated with silane (Monobond-S) & adhesive(Heliobond) and built up composite resin using Teflon mold. Accomplished specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture(kg) was recorded. Shear bond strength data were analyzed with one way ANOVA and Duncan tests.(P<.05) Results. Maximum shear bond strength was $30.07{\pm}2.41(kg)$ when the ceramic was etched with 4% hydrofluoric acid at 120s. No significant difference was found between phosphoric etchant group and control group with respect to shear bond strength. Conclusion. Empress 2 ceramic surface was not etched by phosphoric acid, but etched by hydrofluoric acid.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration (도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향)

  • Kang, Hae-Jin;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • The purpose of this study was to determine whether there were differences in shear bond strength to human dentin using IDS technique compared with DDS. Forty freshly extracted human molars were and devided into 4 groups. The control group specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent and cemented with resin cement. The IDS/SE(immediate dentin sealing, Clearfil$^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, Adapter$^{TM}$ Single Bond 2) specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent(Clearfil$^{TM}$ SE Bond and Adapter$^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. IDS/SE, IDS/SB and DDS specimens were thermocycled. Following that delay, specimens were cemented with resin cement. The dentin bonding agent was left unpolymerized until the application of porcelain restoration. Shear bond strengths were measured using a universal testing machine. Specimens also were evaluated for mode of fracture using an optical microscope. The mean shear bond strengths of control group and IDS/SE groups were not statistically different from one another. The bond strength of IDS/SE group had a significantly higher mean than that of DDS group. There was no significant difference in the mean shear bond strength between IDS/SB(4.11MPa) and DDS group. The evaluation of failure modes indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS group were interfacial. When preparing teeth for indirect ceramic restoration, IDS with Clearfil$^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.

Study about shear bond strength of zirconia core used in dental prosthesis (치과 보철물에 사용되는 지르코니아 코어의 전단결합강도에 관한 연구)

  • Sim, Ji-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the IPS e.max $ZirCAD^{(R)}$ zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing to the conventional metal ceramic system. Methods: The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength of zirconia core ceramic(IPS e.max $ZirCAD^{(R)}$) and their manufacture recommended two veneering ceramic systems(IPS e.max $ceram^{(R)}$, IPS e. max $ZirPress^{(R)}$). A metal ceramic system(Bellabond $plus^{(R)}$, VITA $VM13^{(R)}$) was used as a control group for the two all ceramic system test groups. The maximum loading and shear bond strength was measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test(${\alpha}$=.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were MBSB control 43.62(2.13); ZBSB 18.65(1.76); ZPSB 18.89(1.54). The shear strengths of the zirconia cores were not significantly different(P>.05). Microscope examination showed that zirconia specimens presented mixed failure, and base metal alloy specimens showed adhesive failure. Conclusion: There was no siginificant different between the layering technique and the heat pressing technique in the veneering methods on the zirconia cores. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.

Full mouth Rehabilitation in a Patient with Occlusal Collapse with Vertical Dimension Increase (교합 붕괴 환자에서 수직 고경을 증가한 보철 수복 : 증례 보고)

  • Jo, Si-Hoon;Jeong, Su-Yang;Nam, Hyun-Seok;Song, Kwang-Yeob;Park, Ju-Mi;Ahn, Seung-Geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.477-482
    • /
    • 2010
  • In a case of multiple posterior teeth loss, antagonistic teeth extrude to the edentulous space and compensatory occlusion on the remained anterior teeth leads to occlusal trauma. Extrusion of antagonistic teeth breaks down occlusion plane and loss of posterior support bring about severe wear of remained teeth. In this situation, it is needed to restore remained teeth and edentulous space by increasing vertical dimension to obtain prosthodontic rehabilitation space and to correct occlusion plane. In this case report, the patient had a masticatory problem with loss of posterior teeth support and an esthetic problem of shortened anterior teeth. Before the tooth preparation for the prosthodontic restoration, the patient used removable device for 2 months to increase vertical dimension reversibly. After that, he got provisional fixed restoration with irreversible tooth reduction and used it for 3 months. It had spent 5 month to evaluate the adaptation state on final restoration with incresed vertical dimension. The increasing amount was 3 mm, which was relatively in less degree and masticatory system adapted to the increased vertical dimension without any pathologic changes. Final restoration was made to have equal-intensity contacts on all teeth in a verifiable centric relations and immediate disclusion of all posterior contacts the moment the mandible moves in any direction from centric relation. In addition, metal occlusion surface on posterior teeth was applied to prevent excessive muscle activation, occlusal trauma and the porcelain fracture.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

Clinical Evaluation of Implant-Supported Fixed Prostheses (임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가)

  • Park, Chan-Yong;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.317-326
    • /
    • 2013
  • This study was to compare the cumulative survival rate of implant-supported fixed prostheses and to analyze association between risk factors and cumulative survival rate of implant-supported fixed prostheses. In order to assess the clinical status of implant-supported fixed prostheses, individuals who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between 2000 to 2007 were examined. The results of this study were as follows: 1. Length of service of implant-supported fixed prostheses was $6.6{\pm}32.0$ years (mean), 11.7 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 3. Reason of tooth extraction wax found to have statistically significant influence on implant-supported fixed prostheses (P<.05). The longevity of fixed prostheses was low in tooth extraction case due to periodontal disease (median:9.0 years). 4. Location of implant-supported fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in molar region (median:8.8 years). 5. Number of units in implant-supported fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 7. Food impaction (40.5%), porcelain fracture (25.8%), screw loosening (23.6%) were frequent complications.