• Title/Summary/Keyword: porcelain

Search Result 938, Processing Time 0.028 seconds

AN EXPERIMENTAL STUDY ON THE PORCELAIN POROCITY EXERTED BY THE CONTAMINATION OF THE CERAMO-METAL ALLOY AND LIQUID (도재소부전장금관용 합금과 용액의 오염이 기포발생에 미치는 영향에 관한 실험적 연구)

  • Jeun, Young-Chan;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.20 no.1
    • /
    • pp.33-49
    • /
    • 1982
  • This study was undertaken to observe the porcelain porosity exerted by the contamination of the alloy and liquid. The alloy used in this study was Jelstar; liquids were Ceramco Sta-Wet liquid, distilled water and tap water; and Ceramco vacuum porcelain powder was used. The measurements with photomicroscope (x200, Olympus) were made on the porosity, the diameter (mm) of the pores and the numbers of the pores ($No/mm^2$) The results of this study were obtained as follows: 1. In the porosity, the opaque layer contained over 70% of the total porosity, and the porosity was increased about twice in every porcelain layer by the tap water. 2. The contamination of the alloy and liquid caused porosity to increase markedly at the interface of the metal-porcelain. 3. The diameter of the pores were increased about 1.5 times larger by the contaimination of the liquid, and only a slight increase in the opaque layer due to the contamination of the alloy. 4. In the numbers of the pores, there were significant differences according to the contamination of the alloy and the porcelain layer. And the contamination of the liquid caused significant differences only in the opaque layer.

  • PDF

Observation of the Castability and Bonding Strength of a Co-Cr alloy for Porcelain Fused to Metal Crown (도재용착주조관용 Co-Cr합금의 주조성 및 결합강도 관찰)

  • Chung, In-Sung;Kim, Chi-Young;Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2013
  • Purpose: This study was to analyze the castability, surface oxide characteristic of Co-Cr alloy for porcelain fused to metal crown and the bonding strength of porcelain fused to metal crown. Co-Cr and Ni-Cr alloy for porcelain fused to metal crown was used for tests of the castability and surface oxide state and shear bonding strength by various porcelain. The aim of this study was to suggest the differences of result according to Co-Cr and Ni-Cr alloy. Methods: The kinds of alloy as test specimen was Co-Cr and Ni-Cr alloy. The castability index on the alloy specimens. The surfaces of two alloys were analyzed by SEM and EDX in order to observe oxide characteristic. And the shear test was performed by MTS. Results: The castability index of Co-Cr alloy was 96.8% and Ni-Cr alloy was 94.4%. The strongest bonding strength of Co-Cr alloy was shown 67.37 MPa. Conclusion: The shear bonding strength between Co-Cr alloy and EX3 porcelain was the strongest comparing with others. And all of each alloy was indicated as same level about the castability.

An analysis of shear bond strength of Co-Cr alloy of porcelain fused to metal and ceramic (도재용착용 비귀금속 합금(Co-Cr)과 세라믹의 소성술식에 따른 전단결합강도 분석)

  • Im, Joong-Jae
    • Journal of Technologic Dentistry
    • /
    • v.39 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Purpose: In this study, a corresponding porcelain coating material was applied to dental Co-Cr metal among PFM. Methods: The bonding strength of the fired specimens was measured by a three-point flexural rigidity test. SEM/EDS was used to observe the surface component of specimens. Results: First, All groups were higher than the minimum bonding strength of 25 MPa specified in ISO 9693 for dental metal-ceramics specimens. Second, The bonding strength of control group(WO) is 44.64 MPa. Experimental group DM was 35.45 MPa and DP was 31.82 MPa(P<0.05). Tukey's HSD tests results have shown that the bonding strength in control group(WO) is higher than that of experimental group(DM, DP). Third, In the case of metal - porcelain bonding strength, the application of opaque porcelain and firing were higher than those of the group treated with degassing process. Conclusion: The bonding strength was higher when the powder opaque porcelain was applied than the paste opaque porcelain.

Effect of In on Surface Behaviors of Porcelain-Metal Boundary in Low Gold Porcelain Alloys (도재소부용 저금함유금합금에서 도재계면의 표면거동에 미치는 미량원소 In의 영향)

  • Nam, S.Y.;Lee, K.D.
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.15-26
    • /
    • 1999
  • This study was carried out by observing to composition of oxide on the surface of dental porcelain low gold alloy with various Indium additions according to the degassing and analysing the change composition of additional elements In on diffusion behaviors of Porcelain-matal surface. The specimens used were Au-Pd-Ag alloys by small indium addition. These specimens were treated for 10min at $1000^{\circ}C$ in vacuum condition. To investigate the microsturcture of oxidized alloy surface, SEM and EDAX were used, and EPMA were used to investigate the diffusion behaviors of porcelain-metal surface. X-ray diffraction were used to observe the morphological changes in the oxidation zone. The results of this study were obtained as follows ; 1) The hardness of alloy increased with increasing amount of In addition. 2) The formation of oxidation increased with increasing In content after heat treatment. 3) Diffusion of indium elements increased with increasing In content in metal-porcelain surface after firing. 4) The oxidations of alloy surface were mainly $In_2O_3$.

  • PDF

AN EXPERIMENTAL STUDY ON THE CHEMICAL BOND STRENGTH AT THE INTERFACE BETWEEN PORCELAIN AND SUCCESSIVELY RECAST PALLADIUM-SILVER CERAMIC ALLOY (팔라디움-은합금의 반복주조시 도재와 금속간의 화학적 결합에 관한 실험적 연구)

  • Kim, Tae-Kyun;Lee, Sun-Hyung;Yang, Jae-Ho;Chong, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.31-47
    • /
    • 1989
  • The purpose of this study was to evaluate the chemical bond strength of successively recast Pd-Ag ceramic alloys with porcelain and to investigate changes of quantity of trace elements at the metal-porcelain interface. Porcelain was fired as usual manner on the each successively recast specimen. Rectangular planar shear test was performed and bond strength was measured by Instron universal testing machine. Diffusion of trace elements at the each interface was observed by ESCA (Electron Spectroscopy for Chemical Analysis). The obtained results were as follows : 1. Chemical bond strength was significantly decreased after second recasting. But in case of first recasting, there was no significant decrease of bond strength statistically (p<0.05). 2. Bond strength was not significantly decreased in each generation, when fifty percents new alloy was added (p<0.05). 3. Ag, Sn and In were observed at the porcelain interface. But Pd was not observed. 4. The quantity of Ag, In ions were progressively increased at the metal-porcelain interface as the casting was repeated. Silver ion was most significantly increased.

  • PDF

A Study on the Application of Ultrasonic Testing for The Interface Integrity Evaluation between Iron and Cement of Porcelain Insulator Cap (자기애자 캡의 금구-시멘트 계면 건전성 평가를 위한 초음파법 활용에 대한 연구)

  • Yoon, Young Geun;Choi, In Hyuk;Son, Ju Am;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.58-65
    • /
    • 2018
  • The life span of the porcelain insulator was made to be 30 years, but currently many of the 154kV NGK porcelain insulators using in Korea are found to have passed the production life. Accidents caused by aged mechanical breakdown can lead to disruption of power supply in some areas, large economic losses, and casualties. Therefore, ultrasonic method, which is one of the non - destructive test methods, is applied as a method for evaluating the integrity of porcelain insulators. In this study, the experiment on the interface of cap was conducted and the difference between the energy difference and the attenuation coefficient of the reflected wave was derived according to the interface state of the steel - cement. The results of this study are expected to be used as the basic data of the ultrasonic testing to evaluate the interface condition of the porcelain insulator cap.

Damage Evaluation of Porcelain Insulators Using the Frequency Response Function (주파수응답함수(FRF)를 이용한 자기 애자의 손상평가)

  • Choi, In-Hyuk;Son, Ju-Am;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

COMPARISON OF SURFACE ROUGHNESS OF VARIOUS LAMINATE VENEER PORCELAIN ACCORDING TO POLISHING METHODS (라미네이트 도재 수복물의 연마 방법에 따른 표면 거칠기의 비교)

  • Kwon, Young-Sook;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.246-265
    • /
    • 1996
  • After adjusting glazed surface of laminate veneer porcelain by reduction in the clinical procedure, an additional polishing procedure is required to smoothen the roughened surface by reduction, as it is difficult to glaze it again in the furnace. In this study, four kinds of laminate veneer porcelain were ground with diamond points as done in the clinical procedure. The adjusted porcelain surface was polished with Durawhite stone, Ceramiste points, Exa cerapol, Porcelain polishing wheel, Diamond polishing paste. The degree of surface roughness was evaluated with SEM and profilometer at each step, The self glazed surface and the glazed surface with glazing powder were compared with the polished surface and surface roughness of four kinds of laminate veneer porcelain according to the polishing method and step were obserbed. The following results were obtained : 1. There was no difference in the average surface roughness Ra value and the surface roughness obserbed under SEM according to the polishing methods and steps used, among the four kinds of laminate veneer porcelain including Colorlogic, Exelco, Vintage, and Vitadur alpha product. 2. Due to porosities, the surface in the course of polishing by polishing instruments was rougher than the glazed surface, evaluated with a SEM. 3. Insta-Glaze diamond polishing paste has no statistical difference with self glazed group 1, although it has a lower value in average surface roughness Ra value. 4. Group 2 which was glazed with galzing powder was lowest in view of SEM, but it revealed higher surface roughness Ra value than group 1, the glazed surface and group 8, polished by diamond polishing paste, due to surface waveness. 5. Proper surface smoothness could not be in the surface roughness analysis of SEM and profilometer by Shofu laminate polishing kit composed of Diamond point, Durawhite stone and Ceramiste points. Based on the results of this study, the following conclusions can be drawn. We obtain low surface roughness than glazed surface by polishing instruments, but not perfect results clinically. In order to obtain a perfect clinical result or a surface smoothness comparable to glazed porcelain there is a need for further improvement of porcelain materials, condensa-tion techniques, polishing instruments and polishing methods. Furthermore card should be taken not to breakdown the glazed surface during the clinical and laboratory procedure.

  • PDF

Evaluation of Color Change according to Process Step of Fused Porcelain to SLM Method (치과용 레이저 선택가공 금속체의 도재 소성단계에 따른 색조변화 관찰)

  • Kim, Chi-Young;Chung, In-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.236-242
    • /
    • 2010
  • The porcelain fused metal was made through the progressive fused process of porcelain on substructure of metal material. The substructure was made using novel SLM method. The objective of this study was to observe the color change of porcelain using spectrophotometer equipment according to porcelain fused step and production methods after conducting the process of casting and SLM method of the substructure. The color change by step was indicated that fused opaque porcelain groups(CN1, CC1, CT1, SC1, ST1) had color difference(${\Delta}E$=30) by comparison with fused body porcelain groups(CN2, CC2, CT2, SC2, ST2) and fused glazing porcelain groups(CN3, CC3, CT3, SC3, ST3) (p<0.05). and there was no color difference between the substrates(CN, CC, CT) made by the casting method and the substrates(SC, ST) made by the SLM method. so, the color change was expressed by fused change of porcelain, and this study showed that the color of porcelain fused metal made by the SLM method can be applied clinical trials.

Corrosion Characteristics of Ni-Cr and Co-Cr Alloy Used as a Dental Prosthesis and Its Adhesion to Porcelain (Ni-Cr과 Co-Cr 합금을 이용한 치과보철물의 부식 특성 및 도재 접합성)

  • Kim, Kijung;Choi, Byungki;Oh, Doorok;Choi, Byung-Sang
    • Corrosion Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • By using Ni-Cr and Co-Cr alloys, porcelain fused to metal (PFM) samples were prepared to examine the interface and the surface corrosion behavior. The potentiodynamic polarization analysis showed that the corrosion current density of Co-Cr alloy ($1.61{\times}10^{-6}A/cm^2$) was three times lower than that of Ni-Cr alloy ($4.83{\times}10^{-6}A/cm^2$) at room temperature. A dental prosthesis consisting of the porcelain fused to Ni-Cr alloy extracted from a patient after approximately four years of usage was examined to assess its resistance to corrosion. OM and SEM images of the metal part revealed a typical pitting corrosion. As compared to porcelain fused to Ni-Cr alloy having a thick layer (${\sim}10{\mu}m$) of oxide at the interface, a relatively thin oxide layer (less than $5{\mu}m$) was formed on Co-Cr alloy, indicating that the interface between Co-Cr alloy and porcelain may have a better adhesion strength than the interface between Ni-Cr alloy and porcelain.