• Title/Summary/Keyword: porcelain

Search Result 938, Processing Time 0.028 seconds

MICROLEAKAGE OF DENTIN BONDING AGENTS IN PORCELAIN LAMINATE VENEER UNDER SIMULATED PHYSIOLOGIC PRESSURE (가상 생리적압력하에서 Porcelain Laminate Veneer 접착시 상아질 접착제의 변연 누출에 관한 연구)

  • Choi, Young-Jin;Lee, Ho-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 1993
  • The purpose of this study was to evlauate the microleakage of 3 dentin bonding agents using different dentin pretreatment method under simulated physilogic pressure in cementing the porcelain laminate veneer. Noncarious 60 human maxillary molars were selected and randomly assigned to 4 groups of 15 each. The group with the margin placed on the enamel was classified as the control and the groups with the margin placed on root surface were subdivided into 3 groups according to the dentin bonding agents used. The group using All Bond 2 was classified as experimental group 1, the group using Scotchbond MP was classified as experimental group 2, and the group using Gluma was classified as experimental group 3. Roots were removed at 3mm below the cementoenamel junction, and reductions of the teeth for the porcelain laminate veneer were done on the mesial 1/2 of the buccal surface of each teeth. The pulp was extirpated and the pulp chamber was cleaned with 37% phosphoric acid for the patency of dentinal tubule. Under simulated physiologic pressure, porcelain laminate veneers were cemented to the teeth using each dentin bonding agent and luting cement. After cementation, all samples were stored at 36t in water for 24 hours and thermocycled for 1500 cycles, then immersed in 0.5% basic fuchsin solution and the teeth were sectioned longitudinally by using diamond saw and the extent of microleakage was measured. The following results were obtained, 1. Microleakage was observed in a few samples of control group but all the samples of experimental groups. 2. The control group showed the less extent of microleakage than the experimental groups. In experimental groups the experimental group 1 & the experimental group 2 showed similiar extent of microleakage and the experimental group 3 showed the greater extent of microleakage than other groups. Conclusively, practicing the porcelain laminate veneers in the clinic, although the margin of the porcelain laminate veneer should be placed on enamel, in the case that it is inevitable to place the margin of the porcelain laminate veneer on the root surface, it is recommened to use dentin bonding agents which use no dentin pretreatment or a dentin pretreatment which can leave the smear plugs.

  • PDF

COMPARISON OF COLOR AND OPACITY OF COPY-MILLED IN-CERAM ALUMINA CORE AND SPINELL CORE (Copy-milled In-Ceram Alumina core와 Spinell core의 색과 불투명도 비교)

  • Bae, Jeong-Sun;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.756-766
    • /
    • 1999
  • This study was performed to evaluate effect on color and opacity of 3 different copy-milled In-Ceram cores by glass infiltration and porcelain veneering. Color was evaluated by the $CIEL^*a^*b^*$ readings were recorded with a Colorimeter, Color difference value(${\Delta}E^*_{ab}$) was calculated and opacity was represented by the contrast ratio. The variance of each color parameter ($L^*,\;a^*,\;b^*$), color difference value, and opacity change after glass-infiltrated and after veneered with porcelain was compared. Three experimental groups were fabricated as follows. Group 1 (Alumina core) 15 Alumina blanks was infiltrated with originally marketed glass (A1) and veneered with porcelain(A1) Group 2 (modified Alumina core) : 15 Alumina blanks was infiltrated with its associated glass(S11) and veneered with porcelain(A1) Group 3 (Spinell core) : 15 Spinell blanks was infiltrated with originally developed glass(S11) and veneered with porcelain(A1). The results were as follows: 1. After glass infiltration, $L^*$ value showed decrease, $a^*$ value showed decrease only group 1(p<0.001) and $b^*$ value showed increase on group 1, increase on group 2, 3(p<0.001). 2. After porcelain veneering, $L^*$ value showed decrease(p<0.001), $a^*$ value showed increase on group 1, decrease on group 2(p<0.05) and $b^*$ value showed decrease on group 1, increase on group 2, 3 (p<0.001). 3. ${\Delta}E^*_{ab}$ between before and after glass infiltration was more than 13.77, and between after glass infiltration and after porcelain veneering more than 19.63. 4. After glass infiltration and porcelain veneering, Alumina showed the lowest $L^*,\;a^*$ value and highest $b^*$ value among 3 different groups (p<0.05). ${\Delta}E^*_{ab}$ between group 1-2, 1-3 was higher than that of group 2-3. 5. After glass infiltration, opacity showed decrease, Group 1 had the highest opacity(p<0.05), but no significant differences between group 2 and 3. Above results suggest that glass infiltration and porcelain veneering effects on color and opacity of In-Ceram core, and that modified In-Ceram Alumina uses single crowns or bridges like In-Ceram Spinell.

  • PDF

THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS (도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향)

  • Seong Dong-Hwan;Lee Im-Gi;Sohng Jin-Won;Bok Won-Mi;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

The Effect of a Au Based Bonding Agent Coating on Non-Precious Metals-Ceramic Bond Strength (비귀금속 합금에 적용한 Au Based Bonding Agent가 금속-도재 결합에 미치는 영향)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.405-412
    • /
    • 2009
  • The purpose of this study investigated the effect of Au coating on adhesion between porcelain matrix and metal substructure interface. Titanium, Ni-Cr alloy and Co-Cr alloy are well known as proper metal for the dental restorations. The success of a porcelain fused to metal (PFM) restoration depends upon the quality of the porcelain-metal bond. However, adhesion between dental alloys and porcelain is related to diffusion of oxygen during ceramic firing. The excessive oxidized layers make hard adhesion between dental alloy and ceramic. Ni-Cr and Co-Cr specimens were divided into test and a control group and Titanium specimens were divided into three test groups and a control group. Each group had 20 specimens. The adhesion characteristics of porcelain and metal with Au coating layer and without Au coating layer were observed with scanning electron microscopy(SEM). The adhesion was evaluated by a biaxial flexure test and volume fraction of adherent porcelain was determined by SEM/EDS analysis. Result of this study suggest that Au coating layer is effective barrier to diffuse oxide layer completely protect non-precious alloys from oxidation during the porcelain firing. The SEM photomicrographs of cross-section specimens showed a smooth interface between Au coating layer and metals and porcelain which suggested proper chemical bonding, and no gap, porosity were observed. The mode of failure was mainly adhesive for Ti tested specimens, but mixed failures with adhesive and cohesive were observed in Ni-Cr and Co-Cr specimens. The adhesion between non-precious metals and porcelain would not be improved by Au coating agent. However, It is suggested that the continuous study is required further investigation and development.

  • PDF

A Review of Porcelain Gallbladder Mimicking a Gallbladder Stone on Ultrasonography (초음파 검사에서 담석으로 오인될 수 있는 자기양담낭에 대한 고찰)

  • Sim, Hyun-Sun;Jung, Hong-Rayng;Lim, Chung-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.323-327
    • /
    • 2008
  • Porcelain gallbladder is a rare disorder by deposition of calcium in the wall of gallbladder. The chronic cholecystitis is reported to produce mural calcification and obstruction to the cystic duct by stone. Since porcelain gallbladder is commonly associatedwith gallbladder cancer, cholecystectomy is prerformed to prevent it. We report here a case of a patient with porcelain gallbladder. This case showedthe typical ultrasonogaphic, computer tomogaphic and radiaographic findings of the disease.

  • PDF

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.