• 제목/요약/키워드: pool fire

검색결과 157건 처리시간 0.027초

종류식 배연 터널 화재시 배연속도가 연소율에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Ventilation Velocity on the Burning Rate in Longitudinal Ventilation Tunnel Fires)

  • 양승신;유흥선;최영기;김동현
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.914-921
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiment using Froude scaling were conducted to investigate the effect of longitudinal ventilation velocity on the burning rate in tunnel fires. The methanol pool fires with heat release rate ranging from 2.02 kW to 6.15 kW and the n-heptane pool fires with heat release rate ranging from 2.23 kW to 15.6 kW were used. The burning rate of fuel was obtained by measuring the fuel mass at the load cell. The temperature distributions were observed by K-type thermocouples in order to investigate smoke movement. The ventilation velocity in the tested tunnel was controlled by inverter of the wind tunnel. In methanol pool fire, the increase in ventilation velocity reduces the burning rate. On the contrary in n-heptane pool fire, the increase in ventilation velocity induces large burning rate. The reason for above conflicting phenomena lies on the difference of burning rate. In methanol pool fire, the cooling effect outweighs the supply effect of oxygen to fire plume, and in n-heptane pool vice versa.

소규모 헥산 풀화재를 이용한 2유체노즐의 소화 특성에 대한 실험적 연구 (Experimental Study on the Extinguishing Characteristics of Twin-fluid Nozzle using a Small-scale Hexane Pool Fire)

  • 정찬석;이치영
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.35-41
    • /
    • 2018
  • 본 연구에서는 2유체노즐을 이용하여 140 ml 헥산 풀화재(Pool fire)에 대한 소화 실험을 수행하였다. 해당 풀화재의 화원(직경 80 mm인 원형) 면적은 $0.005027m^2$이고, 열방출률은 2.81 kW로 측정되었다. 물 공급 유량은 156-483 g/min (~0.156-0.483 l/min), 기체(공기와 질소) 공급 유량은 30-70 l/min이었다. 본 실험조건에서 기체 공급 유량이 많은 경우에 성공적으로 소화가 가능하였다. 소화 가능 영역에서 기체 공급 유량이 적은 경우, 물 공급 유량이 많을 때 화재 소화 소요 시간이 길었고, 물 소모량은 많은 것으로 나타났다. 반면, 기체 공급 유량이 많은 경우, 물 공급유량에 따른 화재 소화 소요 시간 및 물 소모량은 상대적으로 큰 차이가 없는 것으로 나타났다. 한편, 본 실험조건에서 공급 기체의 종류는 소화 가능 여부, 소화 소요 시간, 물 소모량에 큰 영향을 미치지 않는 것으로 측정되었다. 마지막으로 본 실험결과와 단일유체노즐을 이용한 기존 실험결과를 이용하여, 2유체노즐과 단일유체노즐의 140 ml 헥산 풀화재 소화를 위한 물 소모량을 선행적으로 비교 및 검토하였다.

이중격실 Pool 화재에 대한 FDS 검증분석 (Validation of FDS for the Pool Fires within Two Rooms)

  • 배용범;류수현;김윤일;이상규;금오현;박종석
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.60-67
    • /
    • 2010
  • 화재분석모델이 제한사항 내에서 화재 피해를 신뢰성 있게 예측하기 위해서는 화재분석모델에 대한 검증분석이 반드시 이루어져야 하며, 이러한 검증분석 과정은 일반적으로 실증실험 결과와 비교함으로서 이루어진다. 본 연구의 목적은 화재분석모델인 FDS의 이중격실 Pool 화재에 대한 예측 능력을 평가하고, FDS의 중요 입력값(열방출률 및 환기량)의 미소변화에 따른 출력값(온도, 농도, 열유속)의 민감도를 분석하기 위함이다. FDS의 예측능력 평가와 FDS 입력변수의 민감도 분석을 위해 국제공동연구 PRISME 프로잭트로부터 화재실증 결과와 FDS 결과물을 비교분석하였다. 이중격실 Pool 화재에 대한 FDS의 예측능력은 화재실증 실험결과와 비교하여 약 ${\pm}$20% 오차범위를 나타내었다. 또한, FDS의 입력변수에 대한 민감도는 열방출율의 미소변화에 따라 비교적 높은 출력값의 변화가 나타났으며, 환기량의 미소변화에 따라 출력값 변화는 연소생성물의 농도에만 영향을 미쳤다.

CFAST 모델을 이용한 이중격실화재 모사 (Simulation of Pool Fire with Two Rooms Using CFAST Model)

  • 류수현;금오현;김위경;김윤일;배용범;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.444-449
    • /
    • 2008
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. This study aims to predict pool fire phenomena with two rooms using CFAST and to compare CFAST simulation results with PRISME experimental data which can be applicable to the fire of nuclear power plant facility. Five different mass loss rate(MLR) are used in the simulation and the simulated results of specific quantities such as temperature, chemical composition are compared to the experimental data. From this study, the CFAST simulation results with the proper MLR show better similarity and trend with pool fire experimental data.

  • PDF

터널화재시 물분무소화설비의 성능에 대한 실대시험 (A real scale test on performance of water spray systems in tunnel fire)

  • 박경환;소수현
    • 한국터널지하공간학회 논문집
    • /
    • 제12권4호
    • /
    • pp.341-347
    • /
    • 2010
  • 터널화재 시 위험을 경감시키기 위해 설치하는 물분무설비의 성능을 실대 시험을 통해 확인하였다. A급 화재, Pool 화재 및 차량화재시 물분무노즐은 뜨거운 연기의 온도를 낮추는데 효과가 큰 것으로 확인되었다. 또한 터널에 기류가 존재하는 경우에도 냉각효과가 큰 것으로 확인되었다. 이 결과를 통해 물분무설비는 터널화재 시 기류온도를 낮춤으로써 fire jump를 방지하고, 주위의 시설물을 보호할 수 있을 것으로 판단된다.

알칼리 금속염을 함유한 미분무수의 헵탄 Pool Fire 소화 (Extinguishment of n-heptane Pool Fire by Water Mist Containing Alkali Metal Agent)

  • 박재만;신창섭
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.105-111
    • /
    • 2005
  • An experimental study is performed for extinguishing of n-heptane pool fire by water mist containing potassium acetate as a fire suppression additive. Water mist was generated by a single pressure nozzle in a small-scale chamber. The drop size distribution of water mist was measured using laser diffraction(Malvern particle sizer). The flame temperature, oxygen concentration and carbon monoxide concentration were measured. In case of using additives, the fire extinguishing time was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

A Study on the Development of Advanced Model to Predict the Sodium Pool Fire

  • Lee, Yong-Bum;Park, Seok-Ki
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.240-250
    • /
    • 1997
  • Liquid sodium is widely used as a coolant of LMR(Liquid Metal Reactor) because of its physical and nuclear properties. However, the liquid sodium is very chemically reactive with oxygen and water so that the study on the sodium fire plays an important role in the LMR safety analysis. In this study, a sodium fire model is suggested to analyze the sodium pool fire where both the flame and the reaction products are considered. And also, sodium pool fire analysis computer code, SOPA, is developed. The sensitivity study on the experimental parameters such as the thermal radiation from flame to atmospheric gas, the vessel cooling and the duration of sodium spill was performed. The results showed good agreements with experimental data in the literature.

  • PDF

복도에서의 연기 확산 및 유동에 관한 연구 (A Study of Smoke Spread and Flow in a Long Corridor)

  • 김충익;유홍선;김명배;한용식;김진곤;윤명오;김상욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1998년도 추계학술발표회 논문 초록집
    • /
    • pp.29-39
    • /
    • 1998
  • 복도는 사무실용 건물, 호텔 등 공중이용 건물에서 중요한 피난경로의 일부이다. 화재로 복도에 연기가 확산되면 그 온도, 연층의 높이, 유해물질의 농도 등에 따라 피난에 심각한 장애를 가져올 수 있다. 본 연구는 이러한 복도에서의 연기의 확산 및 유동에 관하여 연구하기 위하여 길이 40m의 복도에서 pool fire로부터의 연기 유동에 관한 실제크기의 실험과 수치해석을 수행하였다. 화재실과 그에 접해있는 긴 복도가 있는 실험장치에 직경 15, 20, 30cm의 가솔린 pool을 화재실 중앙에서 점화 시켰다. 연기의 온도 및 이동을 측정하기 위해 전장 중앙선을 따라 열전대를 설치하였고 연층의 두께를 측정하기 위하여 수직방향으로 세곳에 열전대가 부착된 수직봉을 설치하였다. 아르곤 레이저 sheet 과 비디오 카메라를 이용해 연기의 유동을 가시화 하였다.

  • PDF

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.