• 제목/요약/키워드: pool evaporation

검색결과 39건 처리시간 0.023초

확산하는 액체질소의 증발에 관한 실험적 연구 (Experimental Study of the Evaporation of Spreading Liquid Nitrogen)

  • 김명배;최병일;김태훈;도규형;한용식;정경열
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.466-472
    • /
    • 2018
  • The investigation of cryogenic liquid pool spreading is an essential procedure to assess the hazard of cryogenic liquid usage. In this experimental study, to measure the evaporation velocity when the pool is spreading, liquid nitrogen was continuously released onto unconfined concrete ground. Almost all of the reported results are based on a non-spreading pool in which cryogenic liquid is instantaneously poured onto bounded ground for a very short period of time. A simultaneous measurement of the pool location using thermocouples and of the pool mass using a digital balance was carried out to measure the evaporation velocity and the pool radius. A greater release flow rate was found to result in a greater average evaporation velocity, and the evaporation velocity decreased with the spreading time and the pool radius.

비확산 액체질소 풀이 형성된 콘크리트 판의 열전도 모델 평가 (Evaluation of the Heat Conduction Model of Concrete Ground on Which LN2 Non-Spreading Pool Forms)

  • 김명배;;정경열;한용식;조성훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.365-373
    • /
    • 2021
  • In this study, evaporation of LN2 non-spreading pool on concrete plate was dealt with experimentally. The thermophysical properties of concrete, which is a composite material, were obtained by minimizing the difference between the numerical analysis results obtained from the assumed properties and the results from experiments. The thermal energy required for evaporation of the liquid pool is supplied from the concrete plate and the wall of the container. As a result of the measurement, the thermal energy flowing in from the wall was negligible compared to the one supplied from the concrete plate. It was found that the measured evaporation rate of the liquid pool by the heat energy supplied through the concrete plate agrees well with the PTC model except for the initial section of the experiment. The validity of the semi-infinite assumption and the one-dimensional assumption, which are the main conditions of the PTC model, was also verified through experiments. The evaporation rate model in the non-spreading pool discussed in this study can provide a basic frame for the one in the spreading pool, which is a meaningful result considering that the spreading pool is very realistic compared to the non-spreading pool.

연속적으로 누출되는 액체질소 풀의 확산에 관한 실험적 연구 (Experimental Study of Liquid Nitrogen Pool Spreading with Continuous Spill)

  • 최재환;김명배;최병일;김태훈
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.174-180
    • /
    • 2014
  • 연속적으로 누출되는 극저온 액체의 풀 확산을 액체질소를 사용하여 실험적으로 연구하였다. 본 실험을 위해 Cement mortar 재질의 Plate 위에 액체질소를 연속적으로 누출시켜 Plate 표면에서 풀 확산이 일어나도록 하였다. 전자저울을 이용하여 Plate 위에서 증발되는 액체질소의 단위면적당증발률을 측정했고, 시간에 따라 반경 방향으로 퍼지는 액체풀의 확산 거리는 열전대의 온도 변화로부터 측정하였다. 실험 결과 액체질소의 단위면적당증발률은 풀 확산이 진행될수록 감소하는 경향을 보였다.

LiBr 수용액의 수평관 유하액막 증발에 있어서의 열전달계수 특성 (The characteristics of heat transfer coefficient for falling-film evaporation on a horizontal tube with aqueous LiBr solution)

  • 지용해;김동관김무환
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.294-302
    • /
    • 1997
  • Falling-film evaporation experiments for aqueous solution of lithium bromide (LiBr) were performed on a horizontal smooth 19.05-mm-dia copper tube. Average heat transfer coefficients were obtained with varied film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. Heat transfer coefficients increase with increasing system pressure and decreasing concentration. For degrees of wall superheat, the heat transfer coefficient did not't show the distinct trend. For this experimental ranges, heat transfer coefficients showed maximum values at an optimal film Reynolds number. The results of this work were compared with pool boiling data reported previously, and it was shown that the heat transfer performance is superior to the pool boiling.

아세톤 풀 증발 실험을 통한 원격 유·누출 모니터링 시스템의 효용성 확인 (Confirmation of the Efectiveness of Remote Chemical Spills and Leak Monitoring System through Acetone Pool Evaporation Experiments)

  • 김은희;이슬기;마병철
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.25-31
    • /
    • 2022
  • In this study, the spill and leak system is developed to provide real-time remote monitoring of industrial complexes where chemical accidents have been occurring every year. The spill and leak monitoring system uses IR-RCD equipment mounted on a 70m-high steel tower to detect chemical substances, thereby detecting chemical accidents such as leaks, fires, and explosions in real time. If IR-RCD equipment can actually detect chemical substances at a long distance, accurate and rapid initial response can be expected. Therefore, in order to confirm that IR-RCD equipment can detect chemical leakage accidents occurring at a long distance, acetone was selected as the experimental substance and a detection experiment was designed. The experiment was conducted using the acetone pool evaporation method at the wharf which was located 1.5 km away from IR-RCD equipment, and it was confirmed whether IR-RCD equipment could detect acetone in real time through the control monitor.

연속누출을 가지는 액체 풀 확산 모델의 실험적 평가 (Experimentally Evaluation of a Liquid Pool Spreading Model with Continuous Release)

  • 김태훈;도규형;김명배;한용식;최병일
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.659-665
    • /
    • 2015
  • In this study, an experimental investigation is performed for evaluation of a liquid pool spreading model with continuous release. The model considered in this study was developed based on a concept which means that the liquid pool spreading is governed by a balance between an inertia force from gravity and a frictional force from friction with the ground under the whole base of the liquid pool. For evaluation of the model, experimental study is performed. Experimental apparatus is setup for measuring release rate, spreading velocity, and evaporation rate from a liquid pool. The experimental results are compared with results from the model. By applying release and evaporation rates obtained from experiments to solving the model, liquid pool radius variation according to time can be obtained. For evaluation of an effect of friction force in the spreading model, results obtained from the models with and without the friction force are compared with those obtained from the experiments. As a result, it is shown that there exists a large deviation between the results obtained from the model without the friction force and the experimental results. On the other hand, the tendency of liquid pool radius variation according to time is similar between the results obtained from the model without the friction force and the experimental results.

나트륨 염이 첨가된 미분무수의 액체 pool fire소화특성 (Extinguishing Characteristics of Liquid Pool Eire by Water Mist Containing Sodium Salt)

  • 박재만;신창섭
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.13-19
    • /
    • 2005
  • 본 논문에서는 금속염 첨가제를 함유한 미분무수의 소화성능을 연구하고자 아세트산 나트륨을 함유한 단일 액적의 증발속도를 측정하였으며, small-scale 챔버내에서의 헵탄 pool fire에 대한 소화실험을 실시하여, 화염의 온도를 분석함으로써 첨가제에 의한 미분무수 소화특성을 분석하였다. 순수물과 수용액의 증발특성을 비교한 결과 핵비등 영역에서 온도가 높을수록 용해된 첨가제의 석출 및 표면장력의 변화 등 물리적 영향으로 순수물에 비해 수용액의 증발속도가 현저히 느리게 나타났다. 소화실험 결과, 저압에서는 물 액적이 화염의 플림을 뚫지 못하기 때문에 소화는 이루어지지 않았고 단순히 화염의 크기를 작아지게 하였다. 중압에서는 첨가제를 넣었을 경우 액적의 운동량 증가에 따른 물리적 소화효과와 첨가제의 화학적 소화효과가 상승작용을 하여 화염을 억제하였고, 고압에서는 미분무수 시스템의 주요 소화 메커니즘 이외에도 blowing효과에 의해서 화염이 소화되는 것을 관찰할 수 있었다.

순간 누출된 액체의 확산에 관한 2차 섭동 해 (Second-Order Perturbation Solutions of Liquid Pool Spreading with Instantaneous Spill)

  • 김명배;도규형;한용식;최병일
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.513-518
    • /
    • 2010
  • In the present work the second-order perturbation solutions of the simple physical model for liquid pool spreading is obtained for the case of instantaneous spill. To generalize the solution governing equations are non-dimensionalized, and two dimensionless parameters, dimensionless evaporation rate and aspect ratio of the initial pool, are identified to control the governing equations. The dimensional governing equations have three parameters. The second-order solution improves fairly the first-order solution for the pool volume.

누출된 액체의 증발과 확산에 관한 1차 섭동해 (First-Order Perturbation Solutions for Liquid Pool Spreading with Vaporization)

  • 김명배;도규형;한용식;최병일
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.287-291
    • /
    • 2011
  • 증발하면서 원형으로 퍼져가고 있는 액체에 대한 모델을 지배하는 연립 상미분 방정식은 지금까지 수치해석적인 방법으로 풀어 왔는데 본 연구에서 섭동해를 최초로 구하였다. 액체의 순간적인 누출과 연속적인 누출에 대하여 섭동 변수로써 단위면적 당 증발률을 사용하여 1차항까지 섭동해를 구하였다. 1차 섭동해의 계산 결과 풀의 부피에 대하여 초기에는 수치해와 잘 일치 하였으나 후기에는 약간의 차이가 존재하였으며 풀의 반경에 대하여는 두가지 종류의 해가 거의 일치 하였다.

Local Pool Boiling Coefficients on Horizontal Tubes

  • Kang Myeong-Gie
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.860-869
    • /
    • 2005
  • Local pool boiling on the outside and inside surfaces of a 51 mm diameter tube in horizontal direction has been studied experimentally in saturated water at atmospheric pressure. Much variation in local heat transfer coefficients was observed along the tube periphery. On the outside surface the maximum and the minimum are observed at ${\theta}=45^{\circ}$ and $180^{\circ}$, respectively. However, on the inside surface only the minimum was observed at ${\theta}=0^{\circ}$. Major mechanisms on the outside surface are liquid agitation and bubble coalescence while those on the inside surface are micro layer evaporation and liquid agitation. As the heat flux increases liquid agitation gets effective both on outside and inside surfaces. The local coefficients measured at ${\theta}=90^{\circ}$ can be recommended as the representative values of both outside and inside surfaces.