• Title/Summary/Keyword: pool evaporation

검색결과 39건 처리시간 0.018초

Experimental Study of the Evaporation of Spreading Liquid Nitrogen (확산하는 액체질소의 증발에 관한 실험적 연구)

  • KIM, MYUNGBAE;CHOI, BYUNGIL;KIM, TAE-HOON;DO, KYHYUNG;HAN, YONGSHIK;CHUNG, KYUNGYUL
    • Journal of Hydrogen and New Energy
    • /
    • 제29권5호
    • /
    • pp.466-472
    • /
    • 2018
  • The investigation of cryogenic liquid pool spreading is an essential procedure to assess the hazard of cryogenic liquid usage. In this experimental study, to measure the evaporation velocity when the pool is spreading, liquid nitrogen was continuously released onto unconfined concrete ground. Almost all of the reported results are based on a non-spreading pool in which cryogenic liquid is instantaneously poured onto bounded ground for a very short period of time. A simultaneous measurement of the pool location using thermocouples and of the pool mass using a digital balance was carried out to measure the evaporation velocity and the pool radius. A greater release flow rate was found to result in a greater average evaporation velocity, and the evaporation velocity decreased with the spreading time and the pool radius.

Evaluation of the Heat Conduction Model of Concrete Ground on Which LN2 Non-Spreading Pool Forms (비확산 액체질소 풀이 형성된 콘크리트 판의 열전도 모델 평가)

  • KIM, MYUNGBAE;NGUYEN, LE-DUY;CHUNG, KYUNGYUL;HAN, YONGSHIK;CHO, SUNGHOON
    • Journal of Hydrogen and New Energy
    • /
    • 제32권5호
    • /
    • pp.365-373
    • /
    • 2021
  • In this study, evaporation of LN2 non-spreading pool on concrete plate was dealt with experimentally. The thermophysical properties of concrete, which is a composite material, were obtained by minimizing the difference between the numerical analysis results obtained from the assumed properties and the results from experiments. The thermal energy required for evaporation of the liquid pool is supplied from the concrete plate and the wall of the container. As a result of the measurement, the thermal energy flowing in from the wall was negligible compared to the one supplied from the concrete plate. It was found that the measured evaporation rate of the liquid pool by the heat energy supplied through the concrete plate agrees well with the PTC model except for the initial section of the experiment. The validity of the semi-infinite assumption and the one-dimensional assumption, which are the main conditions of the PTC model, was also verified through experiments. The evaporation rate model in the non-spreading pool discussed in this study can provide a basic frame for the one in the spreading pool, which is a meaningful result considering that the spreading pool is very realistic compared to the non-spreading pool.

Experimental Study of Liquid Nitrogen Pool Spreading with Continuous Spill (연속적으로 누출되는 액체질소 풀의 확산에 관한 실험적 연구)

  • Choi, Jaewhan;Kim, Myungbae;Choi, Byungil;Kim, Taehoon
    • Journal of Energy Engineering
    • /
    • 제23권3호
    • /
    • pp.174-180
    • /
    • 2014
  • Experimental study of liquid nitrogen pool spread is carried out when it is continuously released. The liquid nitrogen spreads over a cement mortar plate with continuous release. Evaporation rate per unit area of the liquid nitrogen is measured using a digital balance, and a spreading distance of the liquid pool is measured by thermocouples. It is discovered that the evaporation rate per unit area of liquid nitrogen tends to decrease as the liquid pool spreads.

The characteristics of heat transfer coefficient for falling-film evaporation on a horizontal tube with aqueous LiBr solution (LiBr 수용액의 수평관 유하액막 증발에 있어서의 열전달계수 특성)

  • Ji, Yong-Hae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제21권2호
    • /
    • pp.294-302
    • /
    • 1997
  • Falling-film evaporation experiments for aqueous solution of lithium bromide (LiBr) were performed on a horizontal smooth 19.05-mm-dia copper tube. Average heat transfer coefficients were obtained with varied film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. Heat transfer coefficients increase with increasing system pressure and decreasing concentration. For degrees of wall superheat, the heat transfer coefficient did not't show the distinct trend. For this experimental ranges, heat transfer coefficients showed maximum values at an optimal film Reynolds number. The results of this work were compared with pool boiling data reported previously, and it was shown that the heat transfer performance is superior to the pool boiling.

Confirmation of the Efectiveness of Remote Chemical Spills and Leak Monitoring System through Acetone Pool Evaporation Experiments (아세톤 풀 증발 실험을 통한 원격 유·누출 모니터링 시스템의 효용성 확인)

  • Eun Hee, Kim;Seul Gi, Lee;Byung Chol, Ma
    • Journal of the Korean Society of Safety
    • /
    • 제37권6호
    • /
    • pp.25-31
    • /
    • 2022
  • In this study, the spill and leak system is developed to provide real-time remote monitoring of industrial complexes where chemical accidents have been occurring every year. The spill and leak monitoring system uses IR-RCD equipment mounted on a 70m-high steel tower to detect chemical substances, thereby detecting chemical accidents such as leaks, fires, and explosions in real time. If IR-RCD equipment can actually detect chemical substances at a long distance, accurate and rapid initial response can be expected. Therefore, in order to confirm that IR-RCD equipment can detect chemical leakage accidents occurring at a long distance, acetone was selected as the experimental substance and a detection experiment was designed. The experiment was conducted using the acetone pool evaporation method at the wharf which was located 1.5 km away from IR-RCD equipment, and it was confirmed whether IR-RCD equipment could detect acetone in real time through the control monitor.

Experimentally Evaluation of a Liquid Pool Spreading Model with Continuous Release (연속누출을 가지는 액체 풀 확산 모델의 실험적 평가)

  • KIM, TAEHOON;DO, KYU HYUNG;KIM, MYUNGBAE;HAN, YONG-SHIK;CHOI, BYUNG-IL
    • Journal of Hydrogen and New Energy
    • /
    • 제26권6호
    • /
    • pp.659-665
    • /
    • 2015
  • In this study, an experimental investigation is performed for evaluation of a liquid pool spreading model with continuous release. The model considered in this study was developed based on a concept which means that the liquid pool spreading is governed by a balance between an inertia force from gravity and a frictional force from friction with the ground under the whole base of the liquid pool. For evaluation of the model, experimental study is performed. Experimental apparatus is setup for measuring release rate, spreading velocity, and evaporation rate from a liquid pool. The experimental results are compared with results from the model. By applying release and evaporation rates obtained from experiments to solving the model, liquid pool radius variation according to time can be obtained. For evaluation of an effect of friction force in the spreading model, results obtained from the models with and without the friction force are compared with those obtained from the experiments. As a result, it is shown that there exists a large deviation between the results obtained from the model without the friction force and the experimental results. On the other hand, the tendency of liquid pool radius variation according to time is similar between the results obtained from the model without the friction force and the experimental results.

Extinguishing Characteristics of Liquid Pool Eire by Water Mist Containing Sodium Salt (나트륨 염이 첨가된 미분무수의 액체 pool fire소화특성)

  • Park Jae-Man;Shin Chang-Sub
    • Fire Science and Engineering
    • /
    • 제19권3호
    • /
    • pp.13-19
    • /
    • 2005
  • An experimental study is presented for extinguishing characteristics of liquid fuel fire by water mist containing sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing an additive, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space to measure flame temperature variation. The average evaporation rate of a water droplet containing an additive was lower than that of a pure water droplet at a given surface temperature due to the precipitation of salt in the liquid-film and change of surface tension. In case of using an additive, the flame temperature was lower than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing an additive was increased reducing flame size. And also dissociated metal atoms, sodium, were reacted as a scavenger of the major radical species OH^-,\;H^+$ which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

Second-Order Perturbation Solutions of Liquid Pool Spreading with Instantaneous Spill (순간 누출된 액체의 확산에 관한 2차 섭동 해)

  • Kim, Myung-Bae;Do, Kyu-Hyung;Han, Yong-Shik;Choi, Byung-Il
    • Journal of Hydrogen and New Energy
    • /
    • 제21권6호
    • /
    • pp.513-518
    • /
    • 2010
  • In the present work the second-order perturbation solutions of the simple physical model for liquid pool spreading is obtained for the case of instantaneous spill. To generalize the solution governing equations are non-dimensionalized, and two dimensionless parameters, dimensionless evaporation rate and aspect ratio of the initial pool, are identified to control the governing equations. The dimensional governing equations have three parameters. The second-order solution improves fairly the first-order solution for the pool volume.

First-Order Perturbation Solutions for Liquid Pool Spreading with Vaporization (누출된 액체의 증발과 확산에 관한 1차 섭동해)

  • Kim, Myung-Bae;Do, Kyu-Hyung;Han, Yong-Shik;Choi, Byung-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제35권3호
    • /
    • pp.287-291
    • /
    • 2011
  • We solve the simple physical model for liquid pool spreading with vaporization semi-analytically for the first time, using perturbation techniques. The results are compared with those obtained using numerical methods. We use the evaporation rate per unit area as a perturbation parameter, and first-order solutions are obtained for continuous and instantaneous release. The two solutions are nearly identical with respect to the pool radius. The pool volumes are nearly the same at the early stage of the spread and then start to diverge.

Local Pool Boiling Coefficients on Horizontal Tubes

  • Kang Myeong-Gie
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.860-869
    • /
    • 2005
  • Local pool boiling on the outside and inside surfaces of a 51 mm diameter tube in horizontal direction has been studied experimentally in saturated water at atmospheric pressure. Much variation in local heat transfer coefficients was observed along the tube periphery. On the outside surface the maximum and the minimum are observed at ${\theta}=45^{\circ}$ and $180^{\circ}$, respectively. However, on the inside surface only the minimum was observed at ${\theta}=0^{\circ}$. Major mechanisms on the outside surface are liquid agitation and bubble coalescence while those on the inside surface are micro layer evaporation and liquid agitation. As the heat flux increases liquid agitation gets effective both on outside and inside surfaces. The local coefficients measured at ${\theta}=90^{\circ}$ can be recommended as the representative values of both outside and inside surfaces.