• Title/Summary/Keyword: pool boiling

Search Result 226, Processing Time 0.024 seconds

A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer - (터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 -)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF

A study of Nucleate Boiling Heat Transfer from Artificial Nucleation Sites (세공(細孔)을 갖는 전열면(傳熱面)에서의 핵비등(核沸騰) 열전달(熱傳達)에 관(關)한 연구(硏究))

  • Yim, Chang-Soon
    • Solar Energy
    • /
    • v.1 no.1
    • /
    • pp.30-36
    • /
    • 1981
  • Pool Boiling heat transfer from controlled arrays of artificial nucleation sites was studied experimentally. Distilled water were boiled from artificial sites of uniform size, shape and spacing, drilled in superfinished copper horizontal surfaces at site density of 16, 25, 36, 49, 64, 81, 100 per $2.25cm^2$. The results confirm the boiling heat transfer from artificial sites can be improved by increasing the site density N/A or temperature difference ${\Delta}T$ or both. Following experimental correlation were developed for predicting the heat transfer rate from the heating surface which has artificial sites. $$q/A = C(T_s - T_{sat})^{1.811}(N/A)^{0.41}$$

  • PDF

A Study on the Spray Cooling Characteristics of hot Flat Plates (고온평판의 분무냉각특성에 관한 연구)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF

A Dry-Spot Model for the Prediction of Critical Heat Flux in Water Boiling in Bubbly Flow Regime

  • Ha, Sang-Jun;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.546-551
    • /
    • 1997
  • This paper presents a prediction of critical heat flux (CHF) in bubbly flow regime using dry-spot model proposed recently by authors for pool and flow boiling CHF and existing correlations for forced convective heat transfer coefficient, active site density and bubble departure diameter in nucleate boiling region. Without any empirical constants always present in earlier models, comparisons of the model predictions with experimental data for upward flow of water in vertical, uniformly-heated round tubes are performed and show a good agreement. The parametric trends of CHF have been explored with respect to variations in pressure, tube diameter and length, mass flux and inlet subcooling.

  • PDF

Computational Study of the Mixed Cooling Effects on the In-Vessel Retention of a Molten Pool in a Nuclear Reactor

  • Kim, Byung-Seok;Ahn, Kwang-Il;Sohn, Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.990-1001
    • /
    • 2004
  • The retention of a molten pool vessel cooled by internal vessel reflooding and/or external vessel reactor cavity flooding has been considered as one of severe accident management strategies. The present numerical study investigates the effect of both internal and external vessel mixed cooling on an internally heated molten pool. The molten pool is confined in a hemispherical vessel with reference to the thermal behavior of the vessel wall. In this study, our numerical model used a scaled-down reactor vessel of a KSNP (Korea Standard Nuclear Power) reactor design of 1000 MWe (a Pressurized Water Reactor with a large and dry containment). Well-known temperature-dependent boiling heat transfer curves are applied to the internal and external vessel cooling boundaries. Radiative heat transfer has been considered in the case of dry internal vessel boundary condition. Computational results show that the external cooling vessel boundary conditions have better effectiveness than internal vessel cooling in the retention of the melt pool vessel failure.

Critical heat flux (CHF) in pool boiling under static and rolling conditions

  • Tanjung, Elvira F.;Albdour, Samah A.;Jeong, Yeon Uk;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.520-529
    • /
    • 2020
  • Experimental investigations were attempted to simultaneously observe the vapor behaviors and critical heat flux under static and rolling conditions. From visualization results, vapor initiated, grew, and detached individually in a vertical direction from the static heated surfaces (at 10, 20, and 30°). While under rolling motion, initiated vapor grew, and interacted with each other, resulting in forming a wider dry spot on the heated surface. Also, it was observed that the vapor drifted upward and stayed on the heated surface longer compared to under static condition. The faster the platform rolls, the longer the vapor stay on the heated surface, significantly decreasing the CHF. On the other hand, as the platform rolls slower (at high rolling period), CHF increases. CHF was decreased with increasing maximum rolling amplitude and inclination angle under both conditions (static and rolling). CHF under rolling conditions was noticed to be lower than under static condition except at maximum rolling amplitude of 10°. The bubble departure frequency at a maximum rolling amplitude of 10° was the highest among all of rolling amplitudes, thereby enhancing the CHF. These results indicate that rolling motion significantly affects vapor behaviors and CHF.

Development of an Empirical Correlation to Evaluate the Bundle Effect in Saturated Pool Boiling of Water (물의 포화풀비등에서 다발효과를 평가하기 위한 실험식 개발)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • A new empirical correlation was developed for application to the tandem tubes for saturated water at atmospheric pressure. The correlation was obtained by using experimental data and the least square method to calculate the bundle effect. A statistical analysis was performed to identify the suitability of the correlation. The correlation predicted the experimental data within ${\pm}8%$. The applicable ranges of the correlation correspond to a tube pitch of 28.5~114 mm, an elevation angle of $0^{\circ}{\sim}90^{\circ}$, an inclination angle of $0^{\circ}{\sim}90^{\circ}$, and heat fluxes of $0{\sim}120kW/m^2$ of the lower and upper tubes.

An Experimental Study of Nucleate Boiling Heat Transfer With EHD Technique in CFC-11 and HCFC-123 (Chiller용 냉매 CFC-11과 대체냉매 HCFC-123의 전기장을 사용한 핵비등 열전달 촉진에 관한 연구)

  • Kwak, T.H.;Kim, J.H.;Jung, D.S.;Kim, C.B.;Cha, T.W.;Han, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.365-379
    • /
    • 1994
  • Pool boiling experiments were carried out to study the effect of electric field on nucleate boiling heat transfer. CFC-11 and its alternative HCFC-123 were used as working fluids. Boiling on both single tube and a bundle of five tubes was investigated. Heat flux varied from 5 to $25kW/m^2$ while the applied voltage changed from 0 to 1kV. The results showed that at low heat flux where boiling was not present or very weak, electric field-induced forced convection helped increase the heat transfer coefficients of CFC-11 and HCFC-123 significantly(4-15 times increase). However, at higher heat flux, nucleate boiling of CFC-11 which is a highly dielectric fluid, was not affected significantly by the application of electric field. In contrast to CFC-11, even at high heat flux, nucleate boiling of CFC-11 which has a relatively larger electric conductivity than CFC-11, was vigorously increased up to 2-4 times. The additional power required to apply the electric field was 1-2% of the total power consumption by the heater. The increase in overall heat transfer coefficient of evaporators with HCFC -123 was about 40%, suggesting a considerable reduction in evaporator size with EHD technique.

  • PDF

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • 이종선
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.68-78
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF