• Title/Summary/Keyword: polystyrene particle

Search Result 134, Processing Time 0.027 seconds

Role of Detached Particles During Initial Filtration Phase (여과초기에서의 탈착된 입자의 거동)

  • Kim, Ja-Kyum;Tobiason, John E.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

Particle Separator using Radiation Force (광력을 이용한 입자 분리 장치)

  • Kim, Sang-Bok;Yoon, Sang-Youl;Kim, Sang-Soo;Sung, Hyung-Jin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.55-58
    • /
    • 2007
  • To improve the conventional optical chromatography, the continuous particle separator, the cross-type optical chromatography, is fabricated using micro-channel and fiber optics. A laser beam irradiates into the liquid solution containing particles in the perpendicular to the liquid flow direction. The different sized polystyrene latex micro-spheres, $2.0\;{\mu}m\;{\pm}\;0.02\;{\mu}m$, $5.0\;{\mu}m\;{\pm}\;0.05\;{\mu}m$, and $10.0\;{\mu}m\;{\pm}\;0.09\;{\mu}m$ diameter, are separated in cross-type optical chromatography. The separated particles are delivered to down stream in the micro-channel maintaining the retention distance continuously. The measured retention distances for different sized particles well agree with theoretical predictions.

  • PDF

Measurement of Brownian motion of nanoparticles in suspension using a network-based PTV technique

  • Banerjee A.;Choi C. K.;Kihm K. D.;Takagi T.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.91-110
    • /
    • 2004
  • A comprehensive three-dimensional nano-particle tracking technique in micro- and nano-scale spatial resolution using the Total Internal Reflection Fluorescence Microscope (TIRFM) is discussed. Evanescent waves from the total internal reflection of a 488nm argon-ion laser are used to measure the hindered Brownian diffusion within few hundred nanometers of a glass-water interface. 200-nm fluorescence-coated polystyrene spheres are used as tracers to achieve three-dimensional tracking within the near-wall penetration depth. A novel ratiometric imaging technique coupled with a neural network model is used to tag and track the tracer particles. This technique allows for the determination of the relative depth wise locations of the particles. This analysis, to our knowledge is the first such three-dimensional ratiometric nano-particle tracking velocimetry technique to be applied for measuring Brownian diffusion close to the wall.

  • PDF

Study on Continuous-Flow Particle Separation in a Microchannel using Dielectrophoresis (마이크로 채널 내에서의 유전영동을 이용한 입자의 연속적인 분리에 대한 연구)

  • Ryu, Jeong-Eun;Kang, Kwan-Hyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.56-63
    • /
    • 2010
  • In this work, a dielectrophoresis-based particle-separation device is developed which is to be used to continuously separate particles in microchannels. We fabricated the particle-separation device with combining the benefits of electrode-based DEP and insulator-based DEP. The DEP forces are generated by an array of electrodes located in both sidewalls of a main channel. According to the magnitude and frequency of electrical signals, particles with different dielectric properties experience different DEP forces, and therefore, continuously move along different streamlines in the main flow channel without need of pre-focusing process. Based on this mechanism, we examined the performance of the device by controlling the trajectory of polystyrene particles. This device is applicable to the investigation of dielectric properties of biological cells as well as the continuous separation of biological cells.

Thermophoretic Effect on Particle Deposition Toward a Horizontal Wafer (열영동력이 수평 웨이퍼상의 입자침착에 미치는 영향)

  • 배귀남;박승오;이춘식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.175-183
    • /
    • 1994
  • To investigate thermophoretic effect on particle deposition, average deposition velocity toward a horizontal wafer surface in vertical airflow is measured keeping the wafer surface temperature different from the surrounding air temperature. In the present measurement, the temperature difference is maintained in the range from -10 to $4^{\circ}$ C Polystyrene latex (PSL) spheres of diameter between 0.3 and 0.8 .mu.m are used for the experiment. The number of particles deposited on a wafer surface is estimated from the measurements using a wafer surface scanner (PMS SAS-3600). Experimental data are compared with prediction model results.

Manufacture of Core-Shell Composite Polymer Materials for Nonwoven binder (부직포 바인더용 Core-Shell 복합소재의 제조)

  • Lee, Sun Ryong;Lim, Jae Keel;Seul, Soo Duk
    • Journal of Adhesion and Interface
    • /
    • v.3 no.4
    • /
    • pp.27-36
    • /
    • 2002
  • The organic/organic core-shell composite polymer for nonwomen binder were synthesized by stage polymerization of methyl methacrylate and styrene with ammonium persulfate after preparing monomer pre-emulsion in the presence of anionic surfactant. We study the effect of initiator concentration, $0.79{\times}10^{-3}{\sim}3.16{\times}10^{-3}mol/L$ for core polymer, $2.0{\times}10^{-4}{\sim}8.0{\times}10^{-4}mol/L$ for shell polymer, sulfactant concentration, $1.45{\times}10^{-5}{\sim}4.15{\times}10^{-5}mol/L$ for core polymer, $0.73{\times}10^{-5}{\sim}2.91{\times}10^{-5}mol/L$ for shell polymer on core-shell structure of polymethyl methacrylate/polystyrene and polystyrene/polymethyl methacrylate. Emulsion stability was major test method, particle size and particle size distribution were measured using particle size analyzer and the morphology of the core-shell composite polymer was determined using transmission electron microscope, glass temperature was also measured using differential scanning calorimeter.

  • PDF

Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement (TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교)

  • Kim, Du-Yong;Chung, Hyuck;Park, Jae-Hong;Hyun, Jun-Ho;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

Measurement of Particle Deposition Velocity toward a Horizontal Semiconductor Wafer Using a Wafer Surface Scanner (Wafer Surface Scanner를 이용한 반도체 웨이퍼상의 입자 침착속도의 측정)

  • Bae, G.N.;Park, S.O.;Lee, C.S.;Myong, H.K.;Shin, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.130-140
    • /
    • 1993
  • Average particle deposition velocity toward a horizontal semiconductor wafer in vertical airflow is measured by a wafer surface scanner(PMS SAS-3600). Use of wafer surface scanner requires very short exposure time normally ranging from 10 to 30 minutes, and hence makes repetition of experiment much easier. Polystyrene latex (PSL) spheres of diameter between 0.2 and $1.0{\mu}m$ are used. The present range of particle sizes is very important in controlling particle deposition on a wafer surface in industrial applications. For the present experiment, convection, diffusion, and sedimentation comprise important agents for deposition mechanisms. To investigate confidence interval of experimental data, mean and standard deviation of average deposition velocities are obtained from more than ten data set for each PSL sphere size. It is found that the distribution of mean of average deposition velocities from the measurement agrees well with the predictions of Liu and Ahn(1987) and Emi et al.(1989).

  • PDF

A Continuous Particle-size Sorter Using Negative a Dielectrophoretic Virtual Pillar Array (음의 유전영동에 의한 가상 기둥 어레이를 이용한 연속적 입자 크기 분류기)

  • Chang, Sung-Hwan;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.824-831
    • /
    • 2008
  • We present a continuous size-dependent particle separator using a negative dielectrophoretic (DEP) virtual pillar array. Two major problems in the previous size-dependent particle separators include the particle clogging in the mechanical sieving structures and the fixed range of separable particle sizes. The present particle separator uses the virtual pillar array generated by negative DEP force instead of the mechanical pillar array, thus eliminating the clogging problems. It is also possible to adjust the size of separable particles since the size of virtual pillars is a function of a particle diameter and applied voltage. At an applied voltage of 500 kHz $10\;V_{rms}$ (root mean sqaure voltage) sinusidal wave and a flow rate of $0.40\;{\mu}l\;min^{-1}$, we separate $5.7\;{\mu}m$-, $8.0\;{\mu}m$-, $10.5\;{\mu}m$-, and $11.9\;{\mu}m$-diameter polystyrene (PS) beads with separation purity of 95%, 92%, 50%, and 63%, respectively. The $10.5\;{\mu}m$- and $11.9\;{\mu}m$-diameter PS beads have relatively low separation purity of 50% and 63%. However, at an applied voltage of $8\;V_{rms}$, we separate $11.9\;{\mu}m$-diameter PS beads with separation purity over 99%. Therefore, the present particle separator achieves clog-free size-dependent particle separation, which is capable of size tuning of separable particles.

Large areal particle counting system with CMOS image sensor (CMOS 이미지 센서를 이용한 광영역 입자 계수기)

  • Lee, Seung-Jun;Seo, Yeong-Tai;Ko, Yul;Ji, Chang-Hyeon;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1680-1681
    • /
    • 2011
  • In this paper, particle counting system using a CMOS image sensor is demonstrated. The system utilizes a linear photodetector array as a detection element. Therefore, the particles are detected by large detection region, in contrast to a single detector in conventional particle counting devices, while maintaining the sensitivity. The advantage of proposed system is that particles are detected in a relatively large area without using the particle focusing method. Also, proposed system can be easily integrated with a microfluidic chip by attaching the device underneath the bottom plate of the microfluidic chip. Detection of polystyrene microbeads has been tested at a flow rate of 4.89mm/s. For 21 measurements, proposed system showed an average count error of 7.29% and a standard deviation of 4.74%. Potentially, the proposed system can detect even smaller particles simply by utilizing a higher resolution CMOS image sensor.

  • PDF