• 제목/요약/키워드: polymeric insulator

검색결과 61건 처리시간 0.028초

가교시간에 따른 고분자 재료의 트래킹성과 자외선 열화특성 (Tracking Resistance and UV Degradation Property of Polymeric Insulating Materials by Cross-Link Time)

  • 천종욱;이운용;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.447-450
    • /
    • 2002
  • Recently polymeric insulators and arresters are being used for outdoor high voltage applications. Polymeric insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymeric insulator kind are a relatively new technology, but their expected life is still unknown. In this paper, the material property for polymeric insulating material such as silicone rubber and EPBM is investigated by cross-link time and the relation between tracking resistance and W resistance is analyzed by IEC 60587 and W aging experiment.

  • PDF

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.

전차 선로용 폴리머 현수애자의 적용 기술 (Application Technologies of Polymer Suspended Insulators for the Electric Track Line)

  • 한세원;조한구;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.59-61
    • /
    • 2001
  • Polymeric suspended insulators for the electric track line have been developed. The main elements to design polymeric insulators are the insulation ability related with materials of FRP core and housing, and the optimal structure related with fitting parts and interface characteristics. To confirm the design fitness of insulator samples the electric field distribution by FEM and mechanical stress distribution by NASTRAN program was analysed with housing shed shapes and fitting structure. The leakage distance and breakage voltage properties which are core parameters to determine electric insulation ability are selected according to the requirement values of user specification, then the power frequency wet withstand voltage was specified above 22kV and the leakage distance was required above 290mm. The contamination condition of the electric track line was the heavy class according to IEC 815 in order to retain the enough safety margin against overvoltages.

  • PDF

폴리머 애자용 EPDM 고무의 자외선 열화특성 (UV Aging on EPDM rubber for use in polymer Insulators)

  • 연복희;이상용;안종식;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.62-65
    • /
    • 2001
  • The effects of accelerated UV radiation on EPDM used for a polymeric insulator were investigated by contact angle, surface voltage decay after corona charging, SEM-EDX, ATR-FTIR and XPS. EPDM occurs as loss of hydrophobicity by UV treatment, which followed by surface cracking and chalking. The surface voltage decay on UV-treated EPDM show that the shorter decay time corresponded to the treated samples with a longer UV exposure time. The surface oxygen and aluminum content were found to increase and carbon decrease, as is observed in EDX analysis. The ATR-FTIR and XPS indicated that C-C and C-H groups decreased and the highly oxidized carbon bonds such as C-O, C=O and O-C=O increase with time. Also, the effects of surface charges on hydrophobicity based on our results is discussed.

  • PDF

Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발 (Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software)

  • 조성수;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

S-Transform Based Time-Frequency Analysis of Leakage Current Signals of Transmission Line Insulators under Polluted Conditions

  • Natarajan, A.;Narayanan, Suthanthiravanitha
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.616-624
    • /
    • 2015
  • Flashover of power transmission line insulators due to contamination is a major threat to the reliable operation of power system. This paper deals with the analysis of leakage current characteristics of polymeric insulator using S-Transform technique in order to develop a better diagnostic tool to identify the surface condition of outdoor polymeric insulators. In this work, experiments were carried out on 11 kV silicone rubber insulator under AC voltage at different pollution levels. Moving average technique was adopted to find the trend followed by LC peak at different relative humidity conditions. S-Transform was used to find the relationship between energy and frequency content of the leakage current signal with respect to increase in pollution level over a period of time. From the S-Transform time-frequency contour analysis, point of transition to severe arcing due to increase in pollution and its thershold limit were evaluated. Reported results show that the surface condition of insulators could be easily identified from the S-Transform time-frequency analysis of leakage current signals.

송전용 실리콘 폴리머애자의 산불영향 신뢰성 평가( I ) (Reliability Assessment of Forest Fire on Silicone Polymer Insulators in Transmission Lines( I ))

  • 최인혁;이동일;정용운;유근양
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1199-1204
    • /
    • 2004
  • Most overhead transmission lines in Korea run over the mountain; however, only little study has been made for the effect of mountain fire on polymeric insulator for transmission lines, though the study is significantly required, Therefore, in this study, the authors observed the deformation of the sheds of the insulator under fire, varying the ignition time using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator through dry withstand voltage test, impulse flashover test and tensile load test. As the results of the tests, the following conclusions were obtained, First, when the insulator was subjected to the fire, the electrical characteristics were slightly reduced, but there was no change on the mechanical characteristics, Secondly, the sheds and sheath of the insulator were not non-flammable but less-flammable. These two results show the high mechanical stability and durability of the insulator under severe fire condition, though the electrical characteristics can be deteriorated as the time that the insulator is subjected to fire, goes by.

배전급 고분자 현수애자의 제조기술 개발 (Manufacturing Technique of Suspension Insulator far Distribution Lines Using Composite materials)

  • 홍진영;김영성;지응서;김영찬;백주흠;김동욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.306-310
    • /
    • 1996
  • In this paper a series of developing process for an insulator which can be employed in overhead distribution lines, using polymeric composite materials, is introduced. In order to design an insulator for heavily polluted area, weathershed of alternating type was adopted, which could have longer leakage distance. Modified EVA was used as surface material which has good electrical and mechanical characteristics as well as superior chemical stability. FRP core was covered with above surface material through heat shrinking process. By standardization of each process, higher productivity and lower production cost could be ensured. The developed insulator has been put under various tests including long-term field test and artificial aging test and satisfactory results were obtained.

  • PDF

자외선 노출에 따른 폴리머애자 하우징의 열화특성평가 (Aging Evaluation of Polymer Insulator Housing with UV Exposure)

  • 이병성;한재홍;김찬영;한용희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones