누설 전류 모니터링에 의한 오손된 고분자 애자에서의 섬락 예지 방법 (A Flashover Prediction Method by the Leakage Current Monitoring in the Contaminated Polymer Insulator)

  • 박재준;송영철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권7호
    • /
    • pp.364-369
    • /
    • 2004
  • In this Paper, a flashover prediction method using the leakage current in the contaminated EPDM distribution polymer insulator is proposed. The leakage currents on the insulator were measured simultaneously with the different salt fog application such as 25g, 50g, and 75g per liter of deionized water. Then, the measured leakage currents were enveloped and transformed as the CDFS using the Hilbert transform and the level crossing rate, respectively. The obtained CDFS having different gradients(angles) were used as a important factor for the flashover prediction of the contaminated polymer insulator. Thus, the average angle change with an identical salt fog concentration was within a range of 20 degrees, and the average angle change among the different salt fog concentrations was 5 degrees. However, it is hard to be distinguished each other because the gradient differences among the CDFS were very small. So, the new weighting value was defined and used to solve this problem. Through simulation, it Is verified that the proposed method has the capability of the flashover prediction.

배전용 폴리머 현수애자의 설계해석 (The Design Analysis of Distribution Polymer Suspension Insulator)

  • 이운용;조한구;한동희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성 (A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents)

  • 박재준;송일근;이재봉;천성남
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권3호
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

송전용 실리콘 폴리머애자의 산불영향 신뢰성 평가( I ) (Reliability Assessment of Forest Fire on Silicone Polymer Insulators in Transmission Lines( I ))

  • 최인혁;이동일;정용운;유근양
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1199-1204
    • /
    • 2004
  • Most overhead transmission lines in Korea run over the mountain; however, only little study has been made for the effect of mountain fire on polymeric insulator for transmission lines, though the study is significantly required, Therefore, in this study, the authors observed the deformation of the sheds of the insulator under fire, varying the ignition time using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator through dry withstand voltage test, impulse flashover test and tensile load test. As the results of the tests, the following conclusions were obtained, First, when the insulator was subjected to the fire, the electrical characteristics were slightly reduced, but there was no change on the mechanical characteristics, Secondly, the sheds and sheath of the insulator were not non-flammable but less-flammable. These two results show the high mechanical stability and durability of the insulator under severe fire condition, though the electrical characteristics can be deteriorated as the time that the insulator is subjected to fire, goes by.

실계통에 포설된 송전용 고분자 애자의 AGING 특성 연구 (A Studies on Aging Properties for Transmission Line Polymer Insulators which are Installed in service)

  • 김수연;이상진;하영길;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.152-154
    • /
    • 2001
  • Recently the extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. Especially, it is possible for the Polymer insulator to be aged in according to the environment in which it is used this may bring about the decrease of the duration of voltage application. So, this paper deals with aging property of the polymer insulator installed at real transmission line in the industry area. The contact angle, arc test, tracking test were measured for acquiring the degradation characteristics of silicone rubber and the SEM, XRF, FT-IR tests were measured for analyzing the crack and components. Also the surface leakage current of the polymer insulator was compared with that of the porcelain insulator. Finally, we knew that the aging property was not appeared during seven months at real transmission line in the industry area.

  • PDF

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

송전용 폴리머 애자의 산불영향 신뢰성 평가(I) (Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I))

  • 최인혁;이동일;전영준;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF

전기 절연용 EPDM Compounds (EPDM Compounds for Electric Insulator)

  • 김인환;황성혁;김진국
    • Elastomers and Composites
    • /
    • 제34권5호
    • /
    • pp.407-413
    • /
    • 1999
  • 비세라믹 복합절연소재는 기계적 물성, 환경문제, 대량생산과 용이한 설계등의 우수한 특성으로 인해 전력산업분야에서 관심의 대상이 되어왔다. 또한 세라믹 절연체에 비하여 가볍고, 더욱 강인한 물성을 가진다는 장점이 있다. 본 연구에서는 뛰어난 전기 절연 특성과 우수한 내열, 내산화, 내오존성과 내후성을 가진 ethylene propylene diene monomer(EPDM)를 절연소재로 사용하였다. 특히, EPDM은 다른 고무 복합체에 비해 우수한 소수성을 가지기 때문에 장기간 사용이 가능하다는 점에서 본 연구에서는 EPDM 복합체의 유변학적 물성, 전기적물성, 그리고 접촉각의 측정을 통한 소수성 및 회복력에 관한 연구를 하였다. 또한 SEM을 사용하여 표면 형태학적 연구를 수행하였다.

  • PDF

송전용 폴리머 애자에 대한 산불 영향 평가 (The Influence of Forest Fire on the Polymer Insulator for Transmission Lines)

  • 최인혁;이동일;이철호;강병규;이원교;박준호
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.787-792
    • /
    • 2007
  • To understand the effects of forest fires on polymer insulators for transmission lines, the forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.