• 제목/요약/키워드: polymer electrolyte membrane fuel cell

Search Result 467, Processing Time 0.028 seconds

Commercializing Technology Development of Bipolar Plates for Polymer Electrolyte Membrane Fuel Cell (고분자연료전지용 분리판 상용화 기술개발)

  • Kim, Jeong-Heon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.3
    • /
    • pp.409-414
    • /
    • 2011
  • To promote the industry of PEMFC, the commercialization of its parts especially bipolar plate is needed. The bipolar plate is one of key parts for PEMFC, which occupies cost portion of 5~8% in the system. To replace the bipolar plate of machined graphite highly costly, the stamped thin matal or the molded carbon composite has been developed. According to the merits and demerits of each material and its forming process, the stamped metallic plate has been considered to the bipolar plate of PEMFC for automotive, and on the other hand, the molded composite plate has been considered to one for building applications. Hankook Tire Co., Ltd. has developed the carbon composite material and the manufacturing process for the bipolar plates. The developed bipolar plates were proved to be fully applicable to PEMFC of building applications in characteristics and performance, and so government strategic project to develop the mass-production technology for bipolar plates was started and is being conducted by the company. Through the government project for obtaining both the commercialization technology and production capacity for the bipolar plates, the price and the performance of domestic PEMFCs are expected to become competitive in international market.

A Study on the Safety Performance Evaluation Method of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가방법에 관한 연구)

  • Lee, Jungwoon;Seo, Wonseok;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.127.2-127.2
    • /
    • 2010
  • 우리나라는 기후변화 대응을 준비하기위해 2008년도에 수립한'국가에너지기본계획(2008-2030)'에 따라 2030년까지 신재생에너지 비중을 2.4%에서 11%까지 달성을 목표로 정하고 신재생에너지 분야를 성장시키기 위해 국가기술개발 및 산업화 전략을 수립해 추진하고 있다. 이에 발맞추어 건물용 연료전지시스템의 경우, 2006년도부터 1kW급 가정용 연료전지시스템 모니터링 사업의 일환으로 3년간 210대가 도시가스사 및 지자체 등을 중심으로 설치되어 운전되어지고 있다. 특히, 2010년부터 시범보급사업이 추진되어 올해 200대를 시작으로 2011년에 300대, 2012년에 500대가 일반가정에 보급되어질 예정이다. 하지만 현재 6천만원인 연료전지시스템 가격을 실제 보급가능한 가격인 5백만원 이하로 저감시키는 것이 현 시점에서 가장 시급한 문제로 대두되어지고 있는 실정이다. 본 연구에서는 그린홈 보급확대를 위한 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가방법을 개발하여 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가방법을 제시함으로서, 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과를 제조사에 feedback하여 안전성능 개선에 이바지하고자 한다.

  • PDF

Safety Performance Evaluation of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.90.2-90.2
    • /
    • 2011
  • 세계 각 국에서는 선진국을 중심으로 기후변화와 치솟는 유가에 대응하기 위하여 다양한 에너지원의 확보를 위해 부단히 노력하고 있다. 특히, 신재생에너지원 중 에너지 지속성이 가장 우수한 연료전지의 경우 1kW급 건물용 연료전지시스템이 도시가스 인프라가 가장 우수한 한국 및 일본을 중심으로 상용화에 가장 근접해 있는 실정이다. 일본의 경우 가정용 연료전지시스템 '에너팜'의 일부 제품이 올해부터 200만엔대로 가격을 내려 보급되어질 예정이고, 아직은 경제성이 떨어지지만 연료전지 조기 상용화를 위해 시스템 가격저감을 통한 기술개발이 한창이다. 또한 700W급 고체산화물형 연료전지시스템을 세계에서 처음 시판 계획을 가지고 있다. 국내의 경우 2009년도부터 시작된 '그린홈 보급확대를 위한 건물용 연료전지 보조기기 가격저감 기술개발'연구를 통해 블로워, 밸브, 유량계 및 펌프 등의 보조기기의 단가를 낮추고자 기술개발에 박차를 가하고 있다. 이에 따른 연료전지 부품 가격저감 기술이 국내 건물용 연료전지 시장보급의 활력소가 되기를 기대한다. 본 연구에서는 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가를 통한 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가를 수행하였고, 평가결과의 공유를 통하여 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과 비교를 통하여, 연료전지 부품 인증기준을 재정립하여 연료전지 부품산업의 조기 활성화를 도모하고자 한다.

  • PDF

Mechanical Properties of EPDM Gasket after Long-Term Operations (EPDM 가스켓의 장시간 운전에 따른 기계적 성능변화)

  • Wu, Lan;Kim, Seon-Hak;Cheon, Seung-Ho;Kim, Jin-Su;Hyun, Deok-Su;Kim, Byeong-Heon;Lee, Sung-Kun;Jeong, Jae-Hoon;Ji, Duk-Jin;Oh, Byeong-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.488-494
    • /
    • 2011
  • Gasket plays an important role on sealing of the polymer electrolyte membrane fuel cell (PEMFC) stack. Stack requires gaskets in each cell to keep the hydrogen and air/oxygen within their respective regions. The failure of the gasket creates the problems of fuel leakage, mixing, damage on parts and can be a direct reason for the degrading the efficiency of fuel cell. The purpose of this paper researches on how mechanical properties of EPDM gasket in PEMFC are changed after long-term operations. The EPDM (ethylenepropylene-diene monomer) gaskets are obtained from the stack after long-term operations. DMA (dynamic mechanical analysis) is conducted to access the change of mechanical properties of the EPDM gasket. SEM/EDS (scanning electron microscope/energy dispersive spectroscopy) was used to show the surface topography and chemical characterization on the sample surface.

Safety Performance Evaluation of Technical Independence 5kW Class Fuel Cell System (기술자립형 5kW급 건물용 연료전지시스템 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.82.1-82.1
    • /
    • 2011
  • 최근 국내에서 발생된 대규모 정전사태로 인해 안정적인 전력공급에 대한 국민들의 요구가 커져, 지난 3월 일본 후쿠시마 원전사고 이후 다시 한번 분산전원에 대한 필요성이 대두되어지고 있다. 여러 분산전원 중 연료전지는 다른 에너지원에 비해 에너지의 지속성이 우수하여 가장 안정적인 분산전원 형태의 하나이다. 이에 따라 국내의 경우 우수한 도시가스 인프라로 인해 건물용 연료전지라는 신기술에 대한 국민의 수용성은 점점 높아질 것으로 기대된다. 현재 건물용 연료전지의 경우, 주로 1kW급 연료전지가 시범보급되어 각 가정에 설치되어지고 있으나, 상가, 주유소 및 편의점 등의 상업시설과 생활관 및 소형빌라 등의 집단 주거시설 같은 1kW급 보다 용량을 더 필요로 하는 응용처에 국내에서 개발된 5kW급 연료전지시스템이 적용되어지기를 기대한다. 본 연구에서는 국내 제작된 5kW급 고분자전해질 연료전지시스템의 보급이전에 안전성능 평가를 통해 시스템의 성능 및 안전성 평가결과를 제조사에 피드백 하여 5kW급 건물용 연료전지시스템의 조기 상업화에 앞장서고자 한다. 5kW급 연료전지시스템의 기술개발은 핵심부품인 연료변환기, 스택 및 BOP 기술의 경우 1kW급 연료전지시스템에 적용된 것과는 다른 기술이 필요하고, 단순한 scale-up 과정이 아닌 새로운 기술개발로 제품에 적용시켜야 하는 난점을 가지고 있다. 특히, 연료변환기의 경우 연료 유량의 증가로 인하여 reformer, CO shift 및 Prox 반응기의 유체역학, 열교환 흐름 및 촉매반응 공학적으로 이론을 응용한 새로운 반응기 설계와 제작기술 확립이 선행되어 전체적인 시스템 제작 설계에 반영되어져야 한다. 그러므로 본 연구에서는 연료전지시스템 안전성능 평가를 위해 용량증대에 따른 안전성평가 항목을 검토하고, 5kW급 연료전지시스템평가를 수행하여 시스템의 제품성능, 작동성능 및 계통연계성능에서의 안전성을 확인하였고, 정전 유풍과 같은 이상조건 및 실외 환경에 대한 시스템의 안전성도 확인하였다. 또한 부하운전 조건을 75% 및 50%로 변화시켰을 때 빠른 응답시간과 안정적인 부하변동운전을 확인하였다.

  • PDF

Characterizations of Pt-SPE Electrocatalysts Prepared by an Impregnation-Reduction Method for Water Electrolysis (함침-환원법으로 제조된 수전해용 Pt-SPE 전극촉매의 특성)

  • Jang, Doo-Young;Jang, In-Young;Kweon, Oh-Hwan;Kim, Kyoung-Eon;Hwang, Gab-Jin;Kang, An-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.440-447
    • /
    • 2006
  • Solid polymer electrolyte(SPE) membrane with electrodes embedded on both faces offer unique possibilities for the electrochemical cells like water electrolyzer with fuel cell. The Nafion 117 membrane was used as the SPE, and $Pt(NH_3)_4Cl_2$ and $NaBH_4$ as the electrocatalysts and reducing agent, respectively. The 'impregnation-reduction(I-R) method' has been investigated as a tool for the preparation of electrocatalysts for water electrolyzer by varying the concentration of reducing agent and reduction time at fixed concentration of platinum salt, 5 mmol/L. Pt-SPE electrocatalysts prepared by non-equilibrium I-R method showed the lowest cell voltage of 2.17 V at reduction time, 90 min and with concentration of reducing agent 0.8 mol/L and the cell voltage with those by equilibrium I-R method was 2.42 V at reduction time, 60 min and with concentration of reducing agent 0.8 mol/L. The cell voltage were obtained at a current density $1\;A/cm^2$ and $80^{\circ}C$. In water electrolysis, hydrogen production efficiency by Pt-SPE electrocatalyst is 68.2% in case of non-equilibrium I-R method and 61.2% at equilibrium I-R method.

Comparison of Membrane Degradation of PEMFC by Fenton Reaction and OCV Holding (Fenton 반응과 OCV Holding에 의한 PEMFC 고분자 전해질 막의 열화비교)

  • Oh, Sohyung;Kwag, Ahhyun;Lee, Daewoong;Lee, Mooseok;Lee, Donghoon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.768-773
    • /
    • 2019
  • The Fenton reaction, which evaluates the electrochemical durability of polymer membranes of polymer electrolyte fuel cells (PEMFC), and the degradation of polymer membranes by OCV holding method are compared. The Fenton reaction is a method that can evaluate the chemical durability of the polymer membrane at outside the cell in a shorter time than the OCV Holding method. The Fenton reaction was carried out at 30% hydrogen peroxide, 10 ppm iron, and $80^{\circ}C$ for 24 hours. OCV Holding was driven at $90^{\circ}C$, 30% relative humidity and OCV for 168 hours. The Fenton reaction caused a lot of degradation inside the polymer membrane. On the other hand, in OCV Holding, the membrane thickness was thinned by the entire surface and internal degradation. The fluorine emission rate was more than 10 times higher than that of OCV Holding due to the Fenton reaction. The hydrogen permeation rate increased about 30% at 24 hours of Fenton reaction. At OCV Holding, hydrogen permeability decreased after 24 hours and then increased. As a whole, there was a difference in a membranes deteriorated by Fenton reaction and OCV Holding.

Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier (입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구)

  • Hwang, Jun-Young;Chang, Hyo-Sun;Kang, Kyung-Tae;Kang, Heui-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.361-369
    • /
    • 2011
  • The effect of an increase in the temperature of inlet air on the performance of a membrane humidifier for a PEMFC (Polymer Electrolyte Membrane Fuel Cell) vehicle was investigated both experimentally and numerically. A shell-and-tube type gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling was also conducted in simplified geometry of a single tube to explain this nonlinear behavior. The simulation revealed that the local water flux varies nonlinearly and dramatically along the tube. The analysis was based on the inverse relationship between the increase in temperature and decrease in relative humidity, both of which seriously affect the water conductivity of the membrane.

The Performance Degradation of PEMFCs Fabricated with Different GDLs During Exposure to Simultaneous Sulfur Impurity Poisoning Condition (서로 다른 GDL을 이용한 고분자전해질 막 연료전지의 황불순물 복합피독에 의한 성능 저하)

  • Lee, Soo;Kim, Jae-Hyun;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.146-151
    • /
    • 2013
  • This paper reveals the performance decrease and recovery of PEMFC when the contaminated fuel gas and air source with sulfur impurities such as hydrogen sulfide and sulfur dioxide were simultaneously introduced to anode and cathode, respectively. Three different GDLs were fabricated with different carbon black and activated carbon to prevent an introduction of sulfur compound impurities into MEA. components. The severity of $SO_2$ and $H_2S$ poisoning was depended on concentrations(3 ppm - 10 ppm) of sulfur impurities. Especially, cell performance degradation rate was rapid when MEA fabricated with CN-2 GDL because it had little porosity on GDL surface. Moreover, the cell performance can be recovered up to 90%-95% only with neat hydrogen and fresh air feeding.. Conclusively, MEA fabricated with porous CN-1 GDL showed the best cell performance and recovery efficiency during exposure to poisoning condition by simultaneous sulfur impurities.

Continuous Coating Process Development for PEFC Membrane Electrode Assembly (고분자 연료전지용 MEA 연속 코팅공정 개발)

  • Park, Seok-Hee;Yoon, Young-Gi;Kim, Chang-Soo;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.110-112
    • /
    • 2006
  • Membrane electrode assembly (MEA) for polymer electrolyte fuel cell (PEFC) are commonly prepared in the research laboratory by spraying, screen-printing and brushing catalyst slurry onto membrane or other support material like carbon paper or polyimide film in a batch style. These hand applications of the catalyst slurry are painstaking process with respect to precision of catalyst loading and reproducibility. It has been generally mentioned that the adoption of continuous process is very helpful to develop the reliable product. In the present work, we report the results of using continuous type coater with doctor-blade to coat catalyst slurry for preparing the MEA catalyst layers In a faster and highly reproducible fashion. We show that while expectedly faster than batch style, the machine coater requires the use of slurry of appropriate composition and a properly selected transfer decal material in order to achieve superior MEA plat lnw loading reproducibility. To make highly viscous catalyst slurry that is imperative for using coater, we use 40wt.% Nafion solution and minimize the content of organic solvent. And the choice of proper high surface area catalyst is important in the viewpoint of making well-dispersed slurry. After catalyst coating onto the support material, we transferred the catalyst layer to both sides of Nafion membrane by hot-pressing In this case, the degree of transfer was Influenced by hot-pressing condition including temperature, pressure, and time. To compare the transferring ability, we compared so many films and detaching papers. And among the support, polyethylene terephthalate(PET) film shows the prominent result.

  • PDF