• Title/Summary/Keyword: polyethylene glycol(PEG)

Search Result 442, Processing Time 0.043 seconds

Effects of Drying Temperature and Acetylation on The Retention of Polyethylene Glycol in Red Pine Wood Disks (건조온도와 아세틸화처리가 소나무 원판의 Polyethylene Glycol 잔류량에 미치는 효과)

  • Lee, Won-Hee;Hong, Seung-Hyun;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.784-791
    • /
    • 2015
  • Polyethylene glycol (PEG) impregnation prevents a red pine disk from cross-sectional checking during drying. Percentage of PEG Retention (PPR) was measured by the experimental methods of aceton extraction and moisture conditioning in a saturated salt solution and the effect of acetylation on PEG impregnated wood was investigated. PPRs of the kiln-dried specimens were much higher than those of the air-dried by at least four times and within the kiln-dried specimens those of the sapwood were higher that those of the heartwood by two times. These results were confirmed by the moisture conditioning experiment. Acetylation increased the weights of the kiln-dried specimens much less than those of the air-dried. It was revealed that acetic anhydride solution eluted PEG-1000 in the specimens. It is concluded that kiln-drying is more effective than air-drying for the increase of PPR and that acetylation eliminates the difference between the kiln- and air-dried specimens.

Rectal Absorption of Acetaminophen from Polyethylene Glycol and Witepsol Suppositories (아세트아미노펜의 Polyethylene glycol 및 Witepsol 좌제의 직장흡수 - 병원제제를 목적으로 한 아세트아미노펜좌제의 조제 및 유용성 검토-)

  • Lee, Hye Suk;Jin, Sun Kyung;Choi, Jung Hwa;Ku, Young Soon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.143-146
    • /
    • 1998
  • Acetaminophen (APAP) suppositories with active ingredients, i.e., polyethylene glycol (PEG), Witepsol H-15 (WH), were prepared for hospital use and investigated on their drug release characteristics and pharmacokinetics. WH was employed as oil-soluble base with an aim of reducing fragility and mucosa irritancy that are common drawbacks found in PEG suppositories. Also hollow type suppository was tried as compared with conventional type suppository. Drug release tests revealed that in most formulations, more than $80\%$ of loaded APAP were released within 20 minutes, except for APAP-WH hollow type suppositories. Significant differences in the plasma concentration profile were observed among four type suppositories. $T_{max}$ of APAP-PEG and APAP-WH suppositories were 90 and 60 minutes, respectively, in hollow types. APAP-WH hollow type suppositories demonstrated fast absorption rates of APAP as compared with those of APAP-PEG suppositories. No burst effect was observed from APAP-WH suppository in contrast to APAP conventional type suppository, whereas AUCs of all the suppositories were similar. APAP-WH hollow type suppository may be an useful dosage form for hospital use.

  • PDF

Solvent Extraction of Polyethylene Glycol by Ethanol in Powder Injection Molded Compacts (분말사출성형체에서 에탄올에 의한 폴리에틸렌글리콜의 용매추출)

  • 조태식
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.665-670
    • /
    • 2001
  • The solvent extraction of polyethylene glycol (PEG) by ethanol has been studied for the powder injection molded compacts of Sr-ferrite/PEG/carnauba wax/HDPE. The extraction rate of PEG is sensitively proportional to the solvent temperature whereas it is inversely proportional to the contents of PEG, the molecular weight of PEG. and the specimen thickness. The high extraction rate of PEG is achieved under the following conditions: solvent temperature of $70^{\circ}C$, PEG contents of 30%, and PEG molecular weight of 400 g/mol. In the early stage of solvent extraction, the non-linear relationship between the extraction rate and the square root of the extraction time indicates that the extraction of PEG does not follow the Fickian behavior. At extraction times longer than 180 min. however, the extraction of PEG follows the Fickian behavior. The extraction fate of PEG by ethanol is about$1.0{ imes}10^{-6}g/cm^2sec$ enough for common applications.

  • PDF

Attenuated Cerebral Ischemic Injury by Polyethylene Glycol-Conjugated Hemoglobin

  • Cho, Geum-Sil;Choi, In-Young;Choi, Yoo-Keum;Kim, Seul-Ki;Cai, Ying;Nho, Kwang;Lee, Jae-Chul
    • Biomolecules & Therapeutics
    • /
    • v.17 no.3
    • /
    • pp.270-275
    • /
    • 2009
  • Polyethylene glycol-conjugated hemoglobin (PEG-Hb) has been proposed as a blood substitute for transfusion due to their plasma expansion and oxygen transport capabilities. The protective effect of PEG-Hb on cerebral hypoxic-ischemic injury was investigated in neonatal hypoxia model and adult rat focal cerebral ischemia model. As intravenously administered 30 min before the onset of hypoxia, PEG-Hb markedly protected cerebral hypoxic injury in a neonatal rat hypoxia model. A similar treatment of PEG-Hb largely reduced the ischemic injury ensuing after 2-h middle cerebral artery occlusion followed by 22-h reperfusion. Consistently, neurological disorder was significantly improved by PEG-Hb. The results indicate that the pharmacological blockade of cerebral ischemic injury by using PEG-Hb may provide a useful strategy for the treatment of cerebral stroke.

Effect of Polyethylene Glycol on Physicochemical Property in Dispersing Film Formulation (분산형 필름제형의 물리적 특징에 미치는 폴리에틸렌글리콜의 영향)

  • Cho, Young Ho;Lee, Jong-Hwa;Lee, Gye Won
    • KSBB Journal
    • /
    • v.31 no.4
    • /
    • pp.291-299
    • /
    • 2016
  • In this study, Indomethacin, the poorly water soluble drug, was selected and prepared dispersing oral disintegrating films according to the molecular weight of polyethylene glycol (PEG) which are sort of dispersing agents. Also the molecular weight and content of PEG were evaluated effect on the degree of dispersion, physical property and dissolution when making oral dispersing film containing indomethacin to find appropriate condition and suggested guidelines of making oral dispersing film. The appropriate dispersing ratio of the amount of surfactants and dispersing agent were 1% and 4%, also the stability dropped in the PEG molecular weight of 4000 or more. Drying time of oral dispersing film was $90^{\circ}C$ for 10 minutes to 12 minutes that dispersing film's property about flexibility, detachability were very good. The oral dispersion film's content used PEG 400 was $98.6{\pm}0.5%$ and the most uniform. As the molecular weight of PEG increased, dissolution time also increased. On the basis of evaluation parameter, PEG with 400~600 of molecular weight was selected as good dispersing agent in oral dispersing film. Therefore, it can be suggested guideline of preparation application study in oral dispersing film.

Efficacy of ramosetron in combination with polyethylene glycol of preparing for a colonoscopy

  • Kang, Min Kyu;Jang, Byung Ik;Park, Jun Suk;Kim, Kyeong Ok
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.99-104
    • /
    • 2019
  • Background: Because of its efficacy and safety, polyethylene glycol (PEG) is generally used to prepare for colonoscopy. However, the side effects of PEG, including nausea, vomiting, abdominal discomfort, pain, and general weakness, tend to decrease patient compliance and satisfaction. The aim of this study is to investigate the efficacy and safety of PEG with 0.1 mg ramosetron on colonoscopy patients who had difficulty taking PEG due to side effects or large volume. Methods: From January to August in 2012, 28 patients who visited Yeungnam University hospital for a colonoscopy were prospectively enrolled. All enrolled patients were previous history underwent colonoscopy using PEG only in our hospital. The efficacy and safety of ramosetron were assessed through the use of a questionnaire, and compared previous bowel preparation. Results: Compared to previous examination, the patients using the ramosetron reported less nausea, vomiting, abdominal discomfort, and abdominal pain, as well as a higher degree of compliance and satisfaction of the patient. There were no side effects reported with the use of ramosetron. However, overall bowel preparation quality was not better than the previous examination. Conclusion: In case of the use of ramosetron in combination with PEG for bowel preparation, patients experienced a higher rate of compliance and tolerance. Looking forward, ramosetron may become an option of pretreatment for bowel preparation.

Investigation of gamma radiation shielding properties of polyethylene glycol in the energy range from 8.67 to 23.19 keV

  • Akhdar, H.;Marashdeh, M.W.;AlAqeel, M.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.701-708
    • /
    • 2022
  • The mass attenuation coefficients (μm) of polyethylene glycol (PEG) of different molecular weights (1000-200,000) were measured using single-beam photon transmission. The X-ray fluorescent (XRF) photons from Zinc (Zn), Zirconium (Zr), Molybdenum (Mo), Silver (Ag) and Cadmium (Cd) targets were used to determine the attenuation of gamma radiation of energy range between 8.67 and 23.19 keV in PEG samples. The results were compared to theoretical values using XCOM and Monte Carlo simulation using Geant4 toolkit which was developed to validate the experiment at those certain energies. The mass attenuation coefficients were then used to compute the effective atomic numbers, electron density and half value layers for the studied samples. The outcomes showed good agreement between experimental and simulated results with those calculated theoretically by XCOM within 5% deviation. The PEG 1000 sample showed slightly higher μm value compared with the other samples. The dependence of the photon energy and PEG composition on the values of μm and HVL were investigated and discussed. In addition, the values of Zeff and Neff for all PEG samples behaved similarly in the given photon energy range, and they decreased as the photon energy increased.

PEGYLATION: Novel Technology to Enhance Therapeutic Efficacy of Proteins and Peptides (PEG 접합: 단백질 및 펩타이드 치료제의 약효를 증가시키는 새로운 기술)

  • Park, Myung-Ok;Lee, Kang-Choon
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.2
    • /
    • pp.73-83
    • /
    • 2000
  • Polyethylene glycol (PEG) is a water soluble, biocompatible, non-toxic polymer and PEGylation is a well established technique for the modification of therapeutic proteins and peptides. PEG-protein drugs have been extensively studies in relation to therapies for various diseases: cancer, inflammation and others. The covalent attachment of PEG to proteins and peptides prolonged plasma half-life, reduced antigenicity and immunogenicity, increased thermal and mechanical stability, and prevented degradation by enzymes. Several chemical groups for general and site specific conjugation have been exploited to activate PEG for amino group, carboxyl group, and cysteine groups. PEGylation of many proteins and peptides have been studied to enhance their properties for the potential uses. Also, the different positional isomers in several PEG-proteins have shown the difference in vivo stability and biological indicating that the site of PEG molecule attachment is one of the important factor to develop PEG-proteins as potential therapeutic agents.

  • PDF

Characterization of patterned biochip fabricated by using photolithographic method of plasma polymerized polyethylene glycol

  • Choe, Chang-Rok;Choe, Geon-O;Jeong, Dong-Geun;Mun, Dae-Won;Lee, Tae-Geol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.399-399
    • /
    • 2010
  • Polyethylene glycol(PEG)은 강력한 단백질 및 세포흡착 억제력을 가지고 있어 다양한 생물학적 연구에 사용되고 있으나, 기판과의 결합력이 무척 약해 기판 위에 박막을 형성하기가 매우 어렵다는 문제점이 있다. 이번 연구에서는 capacitively-coupled plasma chemical vapor deposition(CCP-CVD)를 이용하여 PEG를 유리 기판 위에 플라즈마 중합하여 plasma-polymerized PEG(PP-PEG) 기판을 만들었다. PP-PEG 박막은 FT-IR, XPS, ToF-SIMS 분석을 통하여 PEG와 매우 유사한 화학적 조성을 가지고 있음을 확인할 수 있었다. 또한 PP-PEG 기판은 photolithography 방법을 이용하여 표면에 photoresist를 패턴한 뒤 아민작용기를 가지는 plasma-polymerized ethylenediamine (PPEDA)를 증착하여 표면이 amine/PEG로 패턴화된 박막 기판을 만들었다. 패턴된 기판에 단백질 및 세포를 고정화하였을 때, 아민 작용기가 노출된 부분에만 고정화가 나타나고 PP-PEG 영역에는 단백질 및 세포의 흡착이 효율적으로 억제되는 것을 형광측정 및 ToF-SIMS chemical imaging 방법을 이용하여 확인하였다. 이러한 바이오칩 제작기술은 단백질 및 세포 칩을 포함한 여러 분야에서 폭넓게 응용될 수 있을 것으로 기대된다.

  • PDF