• Title/Summary/Keyword: pollutant removal

Search Result 369, Processing Time 0.027 seconds

A Study on Efficient Operation of Cosmetic Wastewater Treatment Facility (화장품 폐수처리시설의 효율제고를 위한 처리비 영향인자에 관한 연구)

  • 장명옥;조춘구
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.1
    • /
    • pp.89-106
    • /
    • 1999
  • This research was undertaken to manage the waste treatment facility in cosmetic plants more effectively, The discharge and the treatment of pollutant in cosmetic plants were analyzed. And several factors which had an influential effect of the treatment cost, were found out. Effective management methods are proposed. Since average operating rate is estimated from 29% to 56%, the facility has an 44% to 71% surplus capacity. The pollutant removal rate influences highly on the treatment cost. The amount of MLSS is the factor that effects the removal rate. Chemical cost and the amount of the sludge are the influencing factors. To reduce the waste water treatment cost,-the saving of SV3O use and the management of MLSS amount are essential.

  • PDF

Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Plasma Reactor with a Ferroelectric Pellet Layer (강유전체층을 갖는 선대선 방편 플라즈마장치의 코로나 방전 및 오존발생 특성)

  • 문재덕;신정민;한상옥
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.377-381
    • /
    • 2004
  • A discharge plasma reactor using a ferroelectric pellet packed bed is now used as a removal means of pollutant gases, such as NOx, SOx and VOCs. When an ac voltage is applied to this plasma reactor, then the pellets are polarized, and great electric fields are formed at each top and bottom contact points of the ferroelectric pellets. Thus the points of each pellet become covered with intense corona discharges, where an electrophysicochemical reaction is taking place strongly However these strong discharges also elevate the temperature of the pellets greatly and concurrently decrease the output ozone generation, as a result, the overall removal efficiency of gas becomes decreased greatly A new configuration of discharge plasma reactor using a ferroelectric pellet layer and a wire-to-wire electrode has been proposed and investigated experimentally. It is found that an intensive microdischarge is taking place on the surface of ac corona-charged ferroelectric pellet layer of the proposed reactor, which concurrently enhances the efficiency of plasma generation greatly And, this type of configuration of plasma reactor utilizing a wire-to-wire electrode and a ferroelectric pellet layer could be used as one of effective plasma reactors to remove pollutant gas.

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

Washout Removal Efficiencies of Major Air Pollutants by Precipitation

  • Kim, Dong-Sool;Lim, Deuk-Yong;Heo, Jeong-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study was to quantitatively estimate the washout removal efficiencies of criteria air pollutants such as SO$_2$, TSP, PM10, CO, NO$_2$, and O$_3$corresponding to the amounts and durations of precipitation. The removal patters by washout were studied with air pollutants data and the corresponding precipitation data in Seoul, Korea during the periods of 1990 to 1999. In addition, washout patterns were classified into four seasons and four time Bones, i.e., night, morning, afternoon, and evening. In this study, natures of air pollutants by sequential precipitation were also intensively studied by examining the linear relationships between removal efficiencies and the amounts and durations of precipitation for each pollutant. The results of this study showed that SO$_2$, TSP, and O$_3$were rapidly removed by initial precipitation; however, NO$_2$was slowly removed 2-hour after precipitation. Both CO and PM10 were weakly removed by washout and their removal patters showed to be irregular.

Analysis of water quality improvement efficiency using constructed wetland in a coastal reservoir (연안 담수호 수질오염 방지를 위한 인공습지의 수질정화효율 분석)

  • Hong, Jungsun;Maniquiz-Redillas, Marla C.;Ham, Jong-Hwa;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.292-300
    • /
    • 2016
  • Diverse and comprehensive countermeasures were established to prevent water pollution in coastal areas such as constructed wetlands(CW).This study was conducted to assess the water quality improvement through CW constructed along the shoreline of Hwaseong coastal reservoir. The CW is located in Hwaseong-si, Gyeonggi-do and consisted of a forebay and a wetland. The CW was monitored twice during rainy days and 10 times during dry days. The monitoring results indicated that in and out flowrates were highly correlated with COD and TN loads. COD, TN and TP concentrations in the forebay was lower during dry days than rainy days. However, concentration and mass removal efficiencies of COD, TN and TP were greater during rainy days. In addition, the volume flowing into the CW was less compared to the outflow during rainy days indicating that the CW efficiently reduced the runoff volume. The overall pollutant removal efficiency of the CW were at least 50% for TSS, 20 to 35% for TP, and 26 to 94% for TN. The data gathered may be used to improve the pollutant removal efficiency of the system in the future.

The Evaluation of Pollutant Removal Efficiencies by Sedimentation Basin Types constructed at the Inlets of Irrigation Reservoirs (농업용 저수지 내 침강지의 설치유형에 따른 수질정화효율 평가)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Nam, Gui-Sook;Kwun, Soon-Kuk
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.8 s.157
    • /
    • pp.665-674
    • /
    • 2005
  • The aim of this study is to evaluate 3 types of sedimentation basins: dredging, shield skirt and auxiliary dam, constructed at inlets of two irrigation reservoir and to estimate the most beneficial type and fitted size, SAR(surface to area ratio), for pollutant removal efficiency(RE). For this, RE of major water quality items and change of physicochemical properties in sediments before and post construction of sedimentation basin(SB) were investigated. RE depended on SB types, water quality items and survey times with wide range from $-87\%$ to $92\%$. Long term overall removal efficiency by ROC(regression of concentration) method were $18\%$ in dredging, $29\%$ in shield skirt and $42\%$ in auxiliary dam type. There was a change of physicochemical properties in sediments at auxiliary dam type, while a slight change at dredging and shield skirt type. In comparison to RE, SAR and hydraulic retention time at 3 types of SB, auxiliary dam type was the most beneficial one. Thus, it is recommended that SB would be constructed in completely separated structure from water body of a reservoir with SAR ranged from 0.7 to $1.0\%.$

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Reduction of Pollutant Concentrations in Urban Stormwater Runoff by Settling (침강에 의한 도시 강우 유출수 오염물질 저감 특성 분석)

  • Seo, Dongil;Kim, Jaeyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.210-218
    • /
    • 2016
  • The pollutant removal efficiencies of stormwater runoff by settling were analyzed using field samples collected in 4 different raining events in a test bed installed in the Gwanpyung-Cheon stream in Daejeon. A 1.8 m high with 30 cm diameter cylindrical settling device was used for the settling test by measuring concentration of TSS, TP and TN for time and height. The pollutants removal rate was relatively high in the first 4 hours while 24 hours seem to be necessary to reach steady state in pollutant concentrations. However, there were no considerable differences in concentrations for height at a given time. This indicates most of particulate pollutant in the test seems to show independent settling with no interference to each other. Much part of particle sizes were distributed in the range of $10{\sim}100{\mu}m$. Average particulate fractions of TP and TN were estimated as 52.4% and 23.5%, respectively. This results explain why TN is difficult to remove by simple settling. This study indicates that a simple settling can provide effective method to remove significant amount of TSS and TP effectively and this can be used to protect urban river water quality.

Investigation on the Effect of Stress Waves on Soil Flushing (토양세척에 있어서 탄성파의 효과에 관한 연구)

  • 김영욱;김지형;이인모
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.37-40
    • /
    • 2000
  • Acoustically enhanced soil flushing method is a newly developed in-situ remediation technique. However, there has not been an analytical method that can be used to evaluate the effectiveness of ultrasonic wave under different conditions. This study was undertaken to investigate the degree of enhancement in contaminant removal due to ultrasonic energy on the soil flushing method. The test conditions included different levels of ultrasonic power and hydraulic gradient. The test soils were Ottawa sand, a fine aggregate, and a natural soil, and the surrogate contaminant was a Crisco Vegetable Oil. The test results showed that sonication could increase contaminant removal significantly. Increasing sonication power increased pollutant removal. The faster the flow is, the smaller the degree of enhancement will be. The pollutants in dense soils are more difficult to be removed than in loose soils.

  • PDF

Ion Exchange Processes: A Potential Approach for the Removal of Natural Organic Matter from Water

  • Khan, Mohd Danish;Ahn, Ji Whan
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.70-80
    • /
    • 2018
  • Natural organic matter (NOM) is among the most common pollutant in underground and surface waters. It comprises of humic substances which contains anionic macromolecules such as aliphatic and aromatic compounds of a wide range of molecular weights along with carboxylic, phenolic functional groups. Although the concentration of NOM in potable water usually lies in the range of 1-10 ppm. Conventional treatment technologies are facing challenge in removing NOM effectively. The main issues are concentrated to low efficiency, membrane fouling, and harmful by-product formation. Ion-exchangers can be considered as an efficient and economic pretreatment technology for the removal of NOM. It not only consumes less time for pretreatment but also resist formation of trihalomethanes (THMs), an unwanted harmful by-product. This article provides a comprehensive review of ion exchange processes for the removal of NOM.