• Title/Summary/Keyword: polishing methods

Search Result 199, Processing Time 0.023 seconds

Characteristics of Fe-WC composite powders for Magnetic Abrasive (자성연마용 Fe-WC복합지립의 조직특성)

  • Lee, Yeong-Ran;Bae, Seung-Yeol;Gwon, Dae-Hwan;An, In-Seop;Kim, Yu-Yeong
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.907-911
    • /
    • 2001
  • In order to improve the grindability of magnetic abrasive, Fe-WC magnetic abrasives were made by a plasma melting method after ball milling at various times. This study aims to investigate homogeneously distributed hard phases in Fe matrix and strong bonding between the Fe-matrix and the hard phase. According to XRD, SEM and OM observation, Fe-WC magnetic abrasive powders exhibit the best grindability by plasma melting for 30h ball milling. As a result of magnetic abrasive polishing, the surface roughness, R_{max}$ 5.0$\mu\textrm{m}$, before magnetic abrasive polishing, was reduced to R_{max}$ 2.4$\mu\textrm{m}$. The new magnetic abrasive polishing process is thought to be the useful methods for the automation of three dimensional surface polishing.

  • PDF

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

  • Koc-Vural, Uzay;Baltacioglu, Ismail;Altinci, Pinar
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.118-124
    • /
    • 2017
  • Objectives: This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods: Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between $5-55^{\circ}C$, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex ($Colt\grave{e}ne/Whaledent$), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at $37^{\circ}C$. The color differences (${\Delta}E$) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (${\alpha}=0.05$). Results: Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions: Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation

  • Lee, Du-Hyeong;Mai, Hang-Nga;Thant, Phyu Pwint;Hong, Su-Hyung;Kim, Jaewon;Jeong, Seung-Mi;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.41-47
    • /
    • 2019
  • PURPOSE. Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS. Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (${\alpha}=.05$). RESULTS. The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P<.001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION. Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.

Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing

  • Seong-keun, Yoo;Ye-Hyeon, Jo;In-Sung Luke, Yeo;Hyung-In, Yoon;Jae-Hyun, Lee;Jin-Soo, Ahn;Jung-Suk, Han
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.335-345
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence.

TEM analysis of IBAD/RABiTS substrates prepared by Tripod polishing (Tripod polishing을 이용한 IBAD/RABiTS 기판의 TEM 분석)

  • Choi, Soon-Mee;Chung, Jun-Ki;Yoo, Sang-Im;Park, Chan;Oh, Sang-Soo;Kim, Cheol-Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Sample preparation plays a critical role in microstructure analysis using TEM. Although TEM specimen has been usually prepared by jet-polishing or Ar-ion beam milling technique. these methods could not be applied to YBCO CC which is composed of IBAD or RABiTS substrates, several buffet layers, and YBCO superconducting layer because of big difference in mechanical strengths between the metallic phase and oxide phases. To obtain useful cross-sectional information such as interface between the phases or second phases in YBCO CC, it is prerequisite to secure the large area of thin section in the cross-sectional direction. The superconducting layer or the buffer layers are relatively weak and fragile compared to the metallic substrate such as Ni-5wt%W RABiTS of Hastelloy-based IBAD, and preferential removal of weak ceramic phases during polishing steps makes specimen preparation almost impossible. Tripod polisher and small jig were home-made and employed to sample preparation. The polishing angle was maintained <$1^{\circ}$ throughout the polishing steps using 2 micrometers attached to the tripod plate. TEM specimens with large and thin area could be secured and used for RABiTS/IBAD substrate analyses. In some cases, additional Ar-beam ion milling with low beam current and impinging angle was used for less than 30 sec. to remove debris or polishing media attacked to the specimens.

Observation of surface roughness and grinding angle by automatic barrel finishing process of dental 3D printed resin (3D 프린터로 출력된 치과용 레진의 자동바렐연마공정에 따른 표면 거칠기 및 연마도 관찰)

  • Yu-Jin Park;An-Na Jung
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.39-47
    • /
    • 2023
  • Purpose: This study aimed to confirm the applicability of gloss polishing using automatic barrel finishing with respect to three-dimensional (3D)-printed resin specimens. The surface roughness and grinding angle of the 3D-printed resin specimens were observed with respect to gloss polishing time using automatic dental barrel finishing. Methods: Herein, experiments were conducted on four types of 3D-printed resin specimens. The specimens, with a thickness of 100 ㎛ each, were printed using a 3D printer. Subsequently, light polymerization was performed on these specimens for 15 min. Post this surface treatment, the specimens underwent grinding for 25 min. This process was followed by gloss polishing at 5-min intervals for up to 25 min using automatic dental barrel finishing. The specimens were photographed using a 3D optical microscope, and their surface roughness and grinding angle were measured. Results: The Ra (centerline average roughness) values of all the specimens, except for crown & bridge 10 group and those in the control group that were not polished using automatic barrel finishing, were <0.2 ㎛. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used. Conclusion: Gloss polishing of 3D-printed resin can be realized using automatic dental barrel finishing. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used.

The evaluation of surface roughness and polishing time between polishing systems (연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가)

  • Kim, Ye-Mi;Shin, Su-Jung;Song, Min-Ju;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.

Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia

  • Kim, Hee-Kyung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.296-304
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effect of polishing and glazing on the color and spectral distribution of monolithic zirconia. MATERIALS AND METHODS. Forty-five monolithic zirconia specimens ($16.3mm{\times}16.4mm{\times}2.0mm$) were fabricated and divided into 5 groups according to the number of A2-coloring liquid applications (Group I to V). Each group was divided into 3 subgroups according to the method of surface treatments (n=3): N: no treatment; P: polishing; G: glazing. Color and spectral distribution of five different areas of each specimen were measured according to CIELAB color space in the reflectance mode relative to the standard illuminant D65 on a reflection spectrophotometer. Data were analyzed using one-way ANOVA followed by Tukey's HSD test, Pearson correlation and regression analysis (${\alpha}$=.05). RESULTS. There was a significant difference in CIE $L^*$ between Subgroup N and P, and in CIE $b^*$ between Subgroup P and G in each group. Spectral reflectance generally decreased in Subgroup P and G in comparison with Subgroup N. Color differences between Subgroup P and G were within the perceptibility threshold (${\Delta}E{^*}_{ab}$ < 3.7) in most groups. Highly significant correlation was found between CIE $b^*$ and each subgroups as the number of coloring liquid applications increased ($R^2$ >0.88, P<.001). CONCLUSION. A perceptible color difference can be detected after polishing of monolithic zirconia. Polishing decreases the lightness, and glazing also decreases the lightness, but increases the yellowness of monolithic zirconia.

Evaluation of efficiency of manual polishing over autoglazed and overglazed porcelain and its effect on plaque accumulation

  • Haralur, Satheesh B.
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.179-186
    • /
    • 2012
  • PURPOSE. The aim of this study was to evaluate the efficiency of manual polishing over autoglazed and overglazed porcelain and their effect on plaque accumulation. MATERIALS AND METHODS. Thirty-six porcelain discs were fabricated out of which 18 each was subjected for autoglazing and overglazing. Half surface of the discs was left intact; the remaining half was roughened with medium grit diamond bur. Roughened surfaces were repolished by porcelain polishing kits (Shofu, DFS, Eve). All the surfaces were evaluated by the perthometer and SEM. Six discs from each sample were placed in human volunteer's mouth for 72 hours to evaluate the plaque accumulation. Acquired data was subjected to ANOVA comparative evaluation. RESULTS. Roughened surfaces had average roughness value of $2.88{\pm}0.1935{\mu}m$. The repolished surfaces by porcelain correction kits Shofu, DFS and Eve, average roughness value reduced to $0.6250{\pm}0.1036$, $0.9192{\pm}0.0953$, $0.9017{\pm}0.1305$ respectively. Autoglazed and overglazed surfaces showed the mean roughness value (Ra) of $0.4217{\pm}0.0685$, $0.3450{\pm}0.0729$. SEM study showed the improved surfaces when subjected for polishing. Plaque accumulation percentage was the highest on roughened surface ($93.83{\pm}6.2552%$), followed by porcelain discs polished by commercial kits. Autoglazed surfaces found to be the best surfaces with the least plaque accumulation ($0.5237{\pm}0.4209%$). CONCLUSION. All the polishing kits used in the study reduced the average roughness by approximately 77%. Corrected porcelain surfaces should ideally be reglazed, alternatively, polish the surfaces before final cementation.