• Title/Summary/Keyword: polished surfaces

Search Result 140, Processing Time 0.024 seconds

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

THE SEM STUDY ABOUT THE MORPHOLOGICAL CHANGES OF THE DENTINAL SURFACE IRRADIATED WITH Nd : YAG LASER (Nd : YAG 레이저를 조사한 상아질 표면변화에 관한 주사전자현미경적 연구)

  • Lim, Sung-Sam;Yoon, Soo-Han;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.479-489
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of the Nd : YAG laser on the tooth hypersensitivity by the observation of the morphological changes of the dentinal surface irradiated with Nd : YAG laser by use of SEM. In 40 mandibular and maxillary molars without any carious lesion or restoration, severe attrition and abrasion, Enamel was removed with fine grit diamond bur and exposed dentinal surfaces were polished with Soflex discs. In control group (10 teeth), exposed dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. In the experimental group 1 (10 teeth), acid-etched dentinal surfaces with 10% Maleic acid were prepared by Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) for 2 minutes. In the experimental group 2 (10 teeth), exposed dentinal surfaces were irradiated with Nd: YAG laser (10 watts power, 3 psi water, 10 psi air) until the painted black stains on the dentinal surfaces were completely removed. In the experimental group 3 (10 teeth). dentinal surfaces were prepared with Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) until the painted black stanins on them were completely removed and then the irradiated dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. The specimens were routinely processed and observed with scanning electron microscope. The results were as follows : 1. In the irradiated dentinal surfaces, the characteristics of the melting and recrystalization on the dentinal surfaces were observed. Compared with the results in the control group, we could observe that in the irradiated dentinal surfaces, the aperture of the dentinal tubules were reduced and there were more debris obstructing the dentinal tubules. 2. In the irradiated dentinal surfaces, crater structures were commonly present and in the crater bottoms, there were a lot of bead like melted dentin structures, which had the ruptured opening in the center of them. 3. The melted dentins and cracks in the smear layer were less frequently observed in the irradiated dentinal surfaces using copious cooling water than in the irradiated dentinal surfaces using scare cooling water.

  • PDF

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.

A STUDY ON THE BOND STRENGTH OF REPAIR RESIN TO THE SURFACE TREATED COMPOSITE RESINS (표면처리된 복합레진에 대한 수리용 레진의 결합강도에 관한 연구)

  • Kang, Hyun-Sook;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.487-507
    • /
    • 1995
  • Composite resin repair requires strong bond strength between the new and old materials. The objective of the current study was to identify the optimal treatments for sufficient bond strengths. Bondings between same kinds of materials and cross bondings using chemical curing composites and light curing composites were tested. Surface treatments included the methods of sand-blasting, acid etching and coating of bonding agent. Seven kinds cases of combinations from three kinds of methods were experimented and compared with a control group of which surfaces were highly polished. Measurements of shear bond strength and observations of surface morphologic changes using a scanning electron microscope were done. Following conclusions were drawn : 1. The highest bond strength among composite resins were exhibited by the treatment of the sand-blasting and the coating of bonding agent. 2. Acid etched surfaces showed the lowest bond strength. Bond strengths obtained from experimental groups including acid etching were lower than those obtained from same kinds of experimental groups without acid etching. 3. Simple method of the coating of bonding agent produced the slightly increased bond strength on chemical curing composite and reduced bond strength on light curing composite. 4. Bonding surfaces of chemical curing composite resin showed slightly higher bond strengths than light curing composite resin, however significant differences were not confirmed statistically. 5. More significant irregular surfaces were created by sand-blasting method than acid etching method. 6. A principal component of fillers of both resins was silicon. Acid etching method produced the seperations and degradations of fillers, these were significant on light curing composite resins which containing barium fillers.

  • PDF

Effects of cp-Ti Surface Roughness and Directionality on Initial Cell Attachment Behaviors

  • Shin, Dong-Hoon;Chun, Sungsu;Ahn, Myun-Whan;Song, In-Hwan;Kim, Sukyoung
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.4
    • /
    • pp.338-343
    • /
    • 2012
  • The early osseointegration of titanium (Ti) dental implants is related to the initial cell morphology. The morphology of the cells (mesenchymal stem cells, MSC) was observed on three different Ti disc surfaces, which were mechanically treated by polishing, blasting, and scratching. A non-directional surface (isotropic texture) was obtained by the blasting of HA grits on cp-Ti discs, and a unidirectional surface (anisotropic texture) was obtained by the scratching of SiC papers. The cell attachment and arrangement in the initial periods were quite similar, but those in the later periods were significantly affected by the texture of the cp-Ti discs. After 1 week, the blasted Ti discs showed non-directional arrangement or spreading of the cells, whereas the scratched cp-Ti discs showed unidirectional properties parallel to the direction of the scratched grooves on the surface. The surface roughness of the cp-Ti discs significantly affects cell proliferation. Cell proliferation on the blasted and scratched surfaces was about 60% and 40% higher compared to the control result (polishing group) after 1 week (P<0.05). Cell proliferation on the blasted and scratched surfaces after 1 week was slightly enhanced with increasing surface roughness. It is believed that the direction of cell attachment and arrangement is closely related to the surface texture of the substrate surfaces, but cell proliferation after a relatively long period of time is directly enhanced by the surface roughness, not by the surface texture.

Design of Two Layer Depth-encoding Detector Module with SiPM for PET (SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.319-324
    • /
    • 2019
  • A depth-encoding detector module with silicon photomultipliers(SiPMs) using two layers of scintillation crystal array was designed, and the position measurement capability was verified using DETECT2000. The depth of interaction of the crystal pixels with the gamma rays was tracked through the image acquired with the combination of surface treatment of the crystal pixels and reflectors. The bottom layer was treated as a reflector except for the optically coupled surfaces, and the crystals of top layer were optically coupled each other except for the outer surfaces so that the light sharing was made easier than the bottom layer. Flood images were obtained through the combination of specular reflectors and random reflectors, grounded and polished surfaces of crystal pixels, and the positions at which layer images were generated were measured and analyzed. The images were reconstructed using the Anger algorithm, whose the SiPM signals were reduced as the 16-channels to 4-channels. In the combination of the grounded surface and all reflectors, the depth positions were discriminated into two layers, whereas it was impossible to separate the two layers in the all polished surface combinations. Therefore, using the combination of grounded surface crystal pixels and reflectors could improve the spatial resolution at the outside of the field of view by measuring the depth position in preclinical positron emission tomography.

Correlation Between the Composition of Compliant Coating Material and Drag Reduction Efficiency (유연벽면 점탄성 소재 배합비와 저항저감 효과의 상관관계)

  • Lee, In-Won;An, Nam-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.389-395
    • /
    • 2009
  • A specially designed flat plate was mounted vertically over the axial line in the wind tunnel of the Pusan National University. Strain balances were mounted in the trailing part of the plate to measure the skin friction drag over removable insertions of $0.55{\times}0.25m^2$ size. A set of the insertions was designed and manufactured: 3 mm thick polished metal surface and three compliant surfaces. The compliant surfaces were manufactured of a silicone rubber Silastic$^{(R)}$ S2 (Dow Corning company). To modify the viscoelastic properties of the rubber, its composition was varied: 90% rubber + 10% catalyst (standard), 92.5% + 7.5% (weak), 85% + 15% (strong). Modulus of elasticity and the loss factor were measured accurately for these materials in the frequency range from 40 Hz to 3 kHz. The aging of the materials (variation of their properties) for the period of one year was documented as well. Along with the drag measurement using the strain balance, velocity and pressure were measured for different coating. The strong compliant coating achieved 5% drag reduction within a velocity range $20{\sim}40$ m/s while standard and weak coatings increased drag reduction.

Evaluation of Portable Slipmeter using Human Perception (인간의 인지적 감각을 이용한 휴대용 미끄럼 측정기의 성능평가)

  • Choi, Hyung Jin;Kim, Jung Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.267-271
    • /
    • 2014
  • The objectives of this study were to evaluate the safe criteria of portable slipmeter using human perception onto the several different floor surfaces under contaminated conditions. It was difficult to find why many different slipmeters took there's own safe criteria. It is still unclear how thres hold values established in many literatures. Two different subjective slippery evaluating methods, AHP(Analytic Hierarchy Process) and Friedman test,were used to evaluate the perception of slipperiness of seven different floor surfaces under the contaminated condition with detergent solution. Twelve subjects worn same footwear and walked with self-selected step and cadence along the test floors. The SCOF(Static Coefficient of Friction) obtained for same test conditions with BOT-3000 was compared to perception of slipperiness to establish as a safe criteria. The very high significant correlation(r=0.97) was found between AHP and Friedman test. Also, The high significant correlation(r=0.96) was found between AHP and SCOF obtained with BOT-3000. The results suggested that the SCOF should be greater than 0.63 for safer walking. Perception rating obtained with AHP showed a high correlation with Friedman test and the SCOF obtained with BOT-3000 except for polished tile floor. The safe criteria obtained through this study were similar to ANSI/NFSIB101.1.

A Study on Improving the Efficiency of Magnetic Abrasive Polishing for Die & Mold Surfaces (금형면의 자기연마가공 고효율화에 관한 연구)

  • Lee, Yong Chul;Anzai, Masahiro;Nakagawa, Takeo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.59-65
    • /
    • 1996
  • There are many difficulties in automatic polishing for die & mold surfaces. Even though the process has been studied in the past 15 years, it has not been achieved yet, but by the process of actual hand work of well-skilled workers. A new magentic assisted polishing process, which is one of the potential methods for automation of surface finishing has been studied in the past 10 years by colleagues. The process has many merits, but on the other hand also has demerits, one being low efficiency of grindability by comparision with wheel polish. Therefore, some attempts were tried to improve the grindability by adopting electropolishing, ultra-high speed milling, 5-axis controlled machine etc... most recently by colleagues. This paper also aims to improve the efficiency of polishing by introducing the easily-polished shape surface cutting method equalizing the tool feed per revolution to the pick feed. This cutting method was experimentally confirmed to have sufficient grindability to polish milled surface (with $10{{\mu}m}$Rmax surface roughness) into mirror surface (with $0.4{{\mu}m}$Rmax surface roughness).

  • PDF

AN EXPERIMENTAL STUDY ON THE SURFACE POLISHING EFFECTS OF VARIOUS RESTORATIVE MATERIALS (수종(數種) 수복물(修復物)의 표면(表面) 연마효과(硏磨效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Young-Ho;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.103-114
    • /
    • 1984
  • The purpose of this study was to compare the polished surfaces of two composite resins (Clearfil F and Durafill) with those of glass ionomer cement (Fuji ionomer cement) and to observe what types of polishing devices are valuable, and then to establish a clinically satisfactory procedures. Studies have been undertaken to determine the effects of glass plate matrix and finishing instruments (Carborundum point, White point and Sof-Lex medium) on the surface finish of three restorative materials. The results were examined with profilometer (Kosaka laboratory LTD. Tokyo, Japan) and scanning electron microscopy (JSM-T20: JEOL). The results were as follows: 1. The most satisfactory surface finishes were produced against glass matrix. 2. Coarser finishes were obtained with use of carborundum point. 3. Generally Fuji ionomer cement were left surfaces with higher roughness values. 4. The smoothest finishes were obtained with Sof-lex medium. 5. Clearfil-F was showed more smoother than the other restorative materials.

  • PDF