• Title/Summary/Keyword: pole-transformer

Search Result 108, Processing Time 0.034 seconds

A study on the development of diagnosis device for pole transformer deterior (주상변압기 열화진단장치 개발에 관한 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Kim, Young-Chun;Kim, Hun;Min, Kyung-Rae;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

Study on EMI filter for Eliminating Noise from Pole Transformer for PLC (전력선 통신을 위한 저압변압기에서 발생되는 EMI 노이즈 제거 필터 관한 연구)

  • Kim, Young-Sung;Jeong, Jung-Il;Kim, Jae-Chul;Cho, Sung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.533-534
    • /
    • 2007
  • This paper investigates impulsive noise from a pole transformer in low voltage distribution system for power line communication. EMI noise from the pole transformer is indicated from the experiment. The noise has certain characteristics because it is caused by partial discharge. The noise level is above -35dBm without a filter. Therefore, the filter which is made of ferrite is used in order to eliminate the noise. the noise filters should be applied to both the phase line and the neutral line. Otherwise, It is likely to have little overall impact on elimination of noises. the performance of filter is verified with various experiments. In conclusion, the equivalent circuit of power line communication including noise source is described as a lumped circuit.

  • PDF

A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and (저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구)

  • Min, Yun-Hong;You, Ho-Keun;Bae, Sun-Ki;Kim, Ho-Chul;Lee, Yun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

The Temperature Distribution Analysis of Mold transformer (100kVA 주상용 몰드 변압기의 온도분포 해석)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.125-129
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by FEM(finite element method) to analyze winding temperature rise. In this paper, the temperature distribution and thermal stress analysis of 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

A Study on the Development of Super Low-loss Type Pole Transformer Using the Hybrid Insulation (혼합절연을 이용한 초저손실급 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.84-93
    • /
    • 2007
  • The pole transformer is one of the most important facility to insure the stability of electric power supply. which distributes electricity to customers directly. However there are a lot of defects which are caused by manufacturing fails(in 3 years) or deterioration (in 13 years), so we need a more improved transformer which insures quality. This thesis talks about the development of the new-type transformer using the hybrid insulation that is durable thermally, mechanically, and electrically. It would show how to lay out and produce the transformer using the hybrid insulation. And finally we are sure that we could increase the utilization rate of a transformer by 160% as compared with its own capacity through the overload test. Also, we carried out the examination about the short-circuit and insulation with a 100[kVA] model transformer, so that we expound the analysis of magnetic-mechanical forces intensity and the measure for improving short-circuit efficiency.

Study on Dielectric Characteristics of the Environmental-friendly Pole Transformer using Vegetable Oil (식물성절연유를 사용한 친환경 주상변압기의 절연 특성 연구)

  • Kwag, Dong-Soon;Choi, Jae-Hyeong;Min, Chi-Hyun;Park, Tae-Soo;Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.921-922
    • /
    • 2007
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Analysis of Performance Test of Low-Loss Pole Transformers for distribution Line (저손실형 일단접지 주상변압기의 성능평가 분석)

  • Park, Y.C.;Kim, K.U.;Heo, J.C.;Hwang, B.K.;Roh, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1811-1813
    • /
    • 2001
  • In order to obtain the useful data for quality control of the pole transformer and supply the stable electric power in distribution line, The evaluation of performance for low-loss pole transformer had been performed for new products and ones under operation for several years in distribution line. As the results, we found that the rate of fail were very high in gaskette, short-circuit strength and temperature-rise test, especially 48 percent in gaskette test.

  • PDF

Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System (중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구)

  • Shim, Hae-Sup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.