• Title/Summary/Keyword: point-to-point

Search Result 45,943, Processing Time 0.086 seconds

Histidine-tryptophan-ketoglutarate Versus Blood Cardioplegic Solutions: A Prospective, Myocardial Ultrastructural Study (선천성 심장기형의 수술 후 Histidine-tryptophan-ketoglutarate 심정지액과 혈성 심정지액의 전자현미경적 심근 구조의 비교 관찰)

  • Kim, Si-Ho;Lee, Young-Seok;Woo, Jong-Soo;Sung, Si-Chan;Choi, Pil-Jo;Cho, Gwang-Jo;Bang, Jung-Heui;Roh, Mee-Sook
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.8-16
    • /
    • 2007
  • Background: We performed a prospective clinical study to evaluate the ultrastructural integrity of the myocardium after using Histidine-Tryptophan-Ketoglutarate (HTK) solution in comparison with blood cardioplegic solution during congenital heart surgery. Material and Method: Twenty two patients with acyanotic heart disease, who were scheduled for elective open heart surgery, were randomized into two groups. The HTK Group (n=11) received HTK cardioplegic solution; the blood group (n=11) received conventional blood cardioplegic solution during surgery. The preoperative diagnoses included ventricular septal defect (n=9) and atrial septal defect (n=2) in each group. A small biopsy specimen was taken from the right ventricle's myocardium, and this was processed for ultrastructural examination at the end of 30 minutes of reperfusion. Semiquantitative electron microscopy was carried out 'blindly' in 4 areas per specimen and in 5 test fields per area by 'random systematic sampling' and 'point and intersection counting'. The morphology of the mitochondrial membrane and cristae were then scored. The interstitial edema of the myocardium was also graded. Result: The semiquantitative score of the mitochondrial morphology was $19.65{\pm}4.75$ in the blood group and $25.25{\pm}5.85$ in the HTK group (p=0.03). 6 patients (54.5%) in the blood group and 3 patients (27.3%) in the HTK group were grade 3 or more for the interstitial edema of the myocardium. Conclusion: The ultrastructural integrity was preserved even better with HTK solution than with conventional blood cardioplegic solution.

Effectiveness of Home Economics Class on self-esteem and stress of middle school students (가정과수업이 중학생의 자아존중감과 스트레스에 미치는 효과)

  • Park, Mi Jeong
    • Journal of Korean Home Economics Education Association
    • /
    • v.29 no.3
    • /
    • pp.15-32
    • /
    • 2017
  • This study investigated the effectiveness of home economics class on self-esteem and stress of middle school students. Data were collected from self-reported inventory of the middle school students in Y city of Gyeonggi province and 165 data copies were used for analyses. Data were analyzed for frequency, percentage, mean, standard deviation, Cronbach's ${\alpha}$, t-test, corelation and dependent t-test using SPSS/PC 18.0 program. The results were as follows. First, the average of positive self-esteem was 2.74 and that of negative self-esteem was 1.90 on a 4 Likert scale. The range of stress level was 1.88~2.48 on a 5 Likert scale. Life satisfaction was 3.90 and helpfulness of home economics class was 3.89 on a 5 point Likert scale, which means moderately high. Second, examining differences in variables according to gender, there were statistically significant differences in stress regarding family for both pre- and post-tests. Third, helpfulness of home economics class had positive correlation with positive self-esteem and life satisfaction and had negative correlation with negative self-esteem and stress, which means that home economics class enhance life satisfaction and positive self-esteem and lessen negative self-esteem and stress of middle students. Fourth, as a result of comparison of pre and post-tests, positive self-esteem, life satisfaction, and helpfulness of home economics class increased statistically after home economics classes, while stress regarding school life decreased statistically. Even though students' growth and changes resulting from learning other subjects were not controlled, it was meaningful that effectiveness of home economics class were examined and helpful information for enhancing perception of home economics education were provided.

The Qualities of Northern and Southern Ecotype Garlic Bulbs at Different Storage Temperature (한지형' 및 '난지형' 마늘의 저장온도에 따른 품질 특성)

  • Bae, Ro-Na;Choi, Sun-Young;Hong, Yoon-Pyo
    • Food Science and Preservation
    • /
    • v.15 no.5
    • /
    • pp.635-641
    • /
    • 2008
  • This study was conducted to investigate the optimal sub-zero temperature for storage of two garlic cultivars, the northern ecotype 'Jaerae' and the southern ecotype 'Daeseo'. These cultivars of garlic bulbs were stored at different temperature (room temperature, $0^{\circ}C$, and $-4^{\circ}C$) conditions after predrying. Southern ecotype garlic showed higher weight loss than northern ecotype garlic. Northern ecotype garlic at $-4^{\circ}C$ exhibited less than 5% of weight loss during 10 month storage. Sprouting rate was higher in southern than in northern ecotype at room temperature storage. The value of injury by disease and insect was similar between southern ecotype and northern ecotype for 5 month storage, and then northern ecotype showed higher value of injury by disease and insect than southern ecotype. Hunter 'b' value of northern ecotype garlic was the lowest at $-4^{\circ}C$ storage. Northern ecotype garlic showed no cold injury at freezing point temperature storage. However, southern ecotype garlic had $0{\sim}5.3%$ cold injury occurrence at $-4^{\circ}C$ storage. Respiration and ethylene production exhibited the highest at room temperature storage, those had the slight increase at $0^{\circ}C$ and $-4^{\circ}C$ storages. Northern ecotype showed higher enzymatic pyruvic acid and fructan contents than those of southern ecotype. Enzymatic pyruvic acid content increased and fructan contents decreased during storage time.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

Analysis of Water Quality Improvement Effect by Securing Water Quality Characteristics and Flow Rate in the Geumho River (금호강 수질특성 및 유량확보에 따른 수질개선 효과 분석)

  • Kwak, Insoo;Choi, Boram;Jeon, Hyeryn;Kim, Sunae;Bae, Jaehyeong;Kim, Shin;Kim, Jungmin
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.6
    • /
    • pp.414-429
    • /
    • 2020
  • For the management of rivers, the target water quality is set by establishing the total amount of water pollution and water environment basic plan. For Geumho river T-P has achieved the target water quality, but for BOD, COD, TOC the target water quality of the water environment basic plan has been exceed for the past five years. Therefore, the flow rate for satisfying the target water quality was simulated by analyzing the load, load density, and pollution contribution rate of the Geumho river using BOD, COD, TOC and by utilizing QUAL-MEV a one-dimensional water quality model. According to the analysis of the load, the BOD, COD and TOC all showed the highest levels at the Geumho C point at 9,832.2 kg/day 20,656.6 kg/day, and 15,545.1 kg/day. The load density was highest at 9.47 kg/day/㎢, 37.55 kg/day/㎢, 30.20 kg/day/㎢, and 17.19 kg/day/㎢, 39.14 kg/day/㎢ in Dalseocheon stream during the wet seasons and dry seasons. Pollution contribution rate was highest at about 25 percent for Palgeocheon stream during the wet season and about 50 percent for Dalseocheon stream during the dry season. In addition, the correlation analysis between organic materials showed in the main stream and tributaty of the Geumho river that COD-TOC was 0.8 or higherthan BOD-COD and BOD-TOC in both the wet seasons and dry seasons. And after surveying the total amount of water pollution and the target quality of the water environment basic plan at Geumho C, it was analyzed that an additional flow tate of 14 times and 22 times was needed as of April 2019 (3.46 ㎥/sec).

Synthesis and Lubricating Properties of Succinic Acid Alkyl Ester Derivatives (숙신산 알킬 에스테르 유도체의 합성 및 윤활특성)

  • Baek, Seung-Yeob;Kim, Young-Wun;Chung, Keun-Wo;Yoo, Seung-Hyun;Park, Su-Jin
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.196-202
    • /
    • 2011
  • In this paper, a series of alkyl succinic acid esters for base oil were synthesized by condensation reaction of succinic anhydride and fatty alcohol. The structures of the synthesized esters were confirmed by $^1H-NMR$, FT-IR spectrum and GC analysis. Basic properties of esters such as kinematic viscosity (KV), refractive index (RI), total acid number (TAN) and pour points were measured and lubricating properties such as SRV wear scar diameter (SRV WSD), fraction coefficient (COF) and 4-ball wear (4-ball WSD) were also evaluated. As the results of basic properties, KV, RI and pour point of synthetic esters increased as the carbon chain of the esters increased. Measurement value of total acid number (TAN) was indicated between 0.2~4 mgKOH/g, and that metal working fluids and pressure working oils are acceptable to use as base oil. Also, lubricating properties of the esters showed as follows: 0.391~0.689 mm of SRV WSD, 0.110~0.138 of SRV COF and 0.49~0.55 mm of 4-ball WSD depended on the structure of the esters. In a comparison on the lubrication capacity of the SRV test based on polyester TMPTO, SRV WSD result showed that a better performance caused by the alkyl group. On the other hand, SRV COF test was not influenced of the alkyl group which the capacity of the lubricant was sightly diminished than the comparison material, regardless of the alkyl group.

A Review on Solution Plans for Preventing Environmental Contamination as the Trend Changes of Cryptocurrency (암호화폐의 트랜드 변화에 따른 환경오염 방지 해결방안에 대한 고찰)

  • Kim, Jeong-hun;Song, Sae-hee;Ko, Lim-hwan;Nam, Hak-hyun;Jang, Jae-hyuck;Jung, Hoi-yun;Choi, Hyuck-jae
    • Journal of Venture Innovation
    • /
    • v.5 no.1
    • /
    • pp.91-106
    • /
    • 2022
  • Cryptocurrency, stood out the sharp cost rising of Bitcoin has been spotlighted by means of the solution for stagflation because it is decentralized with an existing currency differently. Especially getting into 4th industrial revolution, technologies using block chain and internet of things have been used in the many fields, and the power of influence is also widespread. Nevertheless like a remark of Elon Musk of Tesla CEO, the problems of environmental contamination for cryptocurrency have been pointed out continuously and the most representative of them is an enormous electric usage as the use of fossil fuels. Also the amount generated of carbon dioxide result in the acceleration of global warming mainly based on the climate changes of earth if the existing mining method is continued. On the other hand, review researches have been conducted restrictively as the connection with environmental contamination as the mining of cryptocurrency. In this study, it intended to review problems for environmental contamination as the diversification of ecological system of cryptocurrency concretely. Upon investigation existing prior documents on the putting recent data first, the mining of cryptocurrency has affected on the environmental contamination conflicting with carbon neutrality as increasement of the electric usage and electronic wastes. And POS method without the mining process appeared, but it had a demerit collapsing a decentralization and then we met turning point on appearing various environmental-friendly cryptocurrency. Finally the appearance of cryptocurrency using new renewable energy acted on the opportunity of the usage maximization of energy storage apparatus and the birth of national government intervention. Based on these results, we mention clearly that hereafter cryptocurrency will regress if not go abreast the value of currency as well as environmental approach.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Status and Prospect of Herbicide Resistant Weeds in Rice Field of Korea (한국 논에서 제초제 저항성잡초 발생 현황과 전망)

  • Park, Tae-Seon;Lee, In-Yong;Seong, Ki-Yeong;Cho, Hyeon-Suk;Park, Hong-Kyu;Ko, Jae-Kwon;Kang, Ui-Gum
    • Korean Journal of Weed Science
    • /
    • v.31 no.2
    • /
    • pp.119-133
    • /
    • 2011
  • Sulfonylurea (SU)-resistant weeds include seven annual weeds such as Monochoria vaginalis, Scirpus juncoides and Cyperus difformis, etc., and three perennial weeds of Scirpus planiculmis, Sagittaria pigmaea and Eleocharis acicularis as of 2010 since identification Monochoria korsakowii in the reclaimed rice field in 1998. The Echinochloa oryzoides resistant to acetyl CoA carboxylase (ACCase) and acetolactate synthase (ALS) inhibitors has been confirmed in wet-direct seeding rice field of the southern province, Korea in 2009. In the beginning of occurrence of SU-resistant weeds the M. vaginalis, S. juncoides and C. difformis were rapidly and individually spreaded in different fields, however, theses resistant weeds have been occurring simultaneously in the same filed as time goes by. The resistant biotype by weed species demonstrated about 10- to 1,000-fold resistance, base on $GR_{50}$ (50% growth reduction) values of the SU herbicides tested. And the resistant biotype of E. oryzoides to cyhalofop-butyl, pyriminobac-methyl, and penoxsulam was about 14, 8, and 11 times more resistant than the susceptible biotype base on $GR_{50}$ values. In history of paddy herbicides in Korea, the introduction of SU herbicides including besulfuron-metyl and pyrazosulfuron-ethyl that control many troublesome weeds at low use rates and provide excellent crop safety gave farmers and many workers for herbicide business refreshing jolt. The products and applied area of SU-included herbicides have been rapidly increased, and have accounted for about 69% and 96%, respectively, in Korea. The top ten herbicides by applied area were composed of all SU-included herbicides by 2003. The concentrated and successive treatment of ACCase and ALS inhibitors for control of barnyardgrass in direct-seeded rice led up to the resistance of E. oryzoides. Also, SU-herbicides like pyrazosulfuron-ethyl and imazosulfuron which are effective to barnyardgrass can be bound up with the resistance of E. oryzoides. The ALS activity isolated from the resistant biotype of M. korsakowii to SU-herbicides tested was less sensitive than that of susceptible biotype. The concentration of herbicide required for 50% inhibition of ALS activity ($I_{50}$) of the SU-resistant M. korsakowii was 14- to 76-fold higher as compared to the susceptible biotype. No differences were observed in the rates of [$^{14}C$]bensulfuron uptake and translocation. ALS genes from M. vaginalis resistant and susceptible biotypes against SU-herbicides revealed a single amino acid substitution of proline (CCT), at 197th position based on the M. korsakowii ALS sequence numbering, to serin (TCT) in conserved domain A of the gene. Carfentrazone-ethyl and pyrazolate were used mainly to control SU-resistant M. vaginalis by 2006, the early period, in Korea. However, the alternative herbicides such as benzobicyclone, to be possible to control simultaneously the several resistant weeds, have been developing and using broadly because the several resistant weeds have been occurring simultaneously in the same filed. The top ten herbicides by applied area in Korea have been occupied by products of 3-way mixture type including herbicides with alternative mode of action for the herbicide resistant weeds. Mefenacet, fentrazamide and cafenstrole had excellent controlling effects on the ACCase and ALS inhibitors resistant when they were applied within 2 leaf stage.