Interface Development for the Point-of-care device based on SOPC

  • Son, Hong-Bum;Song, Sung-Gun;Jung, Jae-Wook;Lee, Chang-Su;Park, Seong-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This paper describes the development of the sensor interface and driver program for a point of care (POC) device. The proposed pac device comprises an ARM9 embedded processor and eight-channel sensor input to measure various bio-signals. It features a user-friendly interface using a full-color TFT-LCD and touch-screen, and a bluetooth wireless communication module. The proposed device is based on the system on a programmable chip (SOPC). We use Altera's Excalibur device, which has an ARM9 and FPGA area on a chip, as a test bed for the development of interface hardware and driver software.

Biosensors (바이오센서)

  • 김의락
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.423-427
    • /
    • 2000
  • Intense research on biosensors has been performed in a number of different institution over the past 15 years, but relatively few commercial products have resultingly, the blood glucose sensor is a good example of a product which penetrated the market. However recently, the development of electrochemical and optical technologies has accelerated the turnover of the research as is illustrated by a rapid increase in the number of point-of-care diagnostic systems and analytical devices. Examples of such biosensors used in the fields of medical diagnostics, bioprocess control, and environmental monitoring are described, and summarized in an introduction to their characteristics, structures, and functions, given.

  • PDF

Reversible and High-Capacity Data Hiding in High Quality Medical Images

  • Huang, Li-Chin;Hwang, Min-Shiang;Tseng, Lin-Yu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.1
    • /
    • pp.132-148
    • /
    • 2013
  • Via the Internet, the information infrastructure of modern health care has already established medical information systems to share electronic health records among patients and health care providers. Data hiding plays an important role to protect medical images. Because modern medical devices have improved, high resolutions of medical images are provided to detect early diseases. The high quality medical images are used to recognize complicated anatomical structures such as soft tissues, muscles, and internal organs to support diagnosis of diseases. For instance, 16-bit depth medical images will provide 65,536 discrete levels to show more details of anatomical structures. In general, the feature of low utilization rate of intensity in 16-bit depth will be utilized to handle overflow/underflow problem. Nowadays, most of data hiding algorithms are still experimenting on 8-bit depth medical images. We proposed a novel reversible data hiding scheme testing on 16-bit depth CT and MRI medical image. And the peak point and zero point of a histogram are applied to embed secret message k bits without salt-and-pepper.

Implementation Plan of Integrated Medical Information System for Ubiquitous Healthcare Service (U-Healthcare 서비스를 위한 통합의료정보시스템의 구축방안)

  • Jung, Yong-Sik
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.115-126
    • /
    • 2010
  • Modern society can be described as ubiquitous computing over the concept of information. Information technology(IT) has been developing in a way that relative technologies are integrated to each other. Especially in ubiquitous environment, medical information industry shows significant interest in the U-healthcare service area. This paper will first look into U-healthcare service environment and component of Integrated Medical Information Systems(IMIS). Secondly, it examines the basic technological factors for integrated medical information systems, which is datawarehouse, network, communication standards and technology related U-healthcare service. Finally it proposes how to implement and operate new integrated medical information system for ubiquitous health care service. The system will do point of care(POC) for customers by real time and diagnose them using their various and personal medical data. The information will be communicated back to the customers, which will improve their satisfaction.

Development of a nucleic acid detection method based on the CRISPR-Cas13 for point-of-care testing of bovine viral diarrhea virus-1b

  • Sungeun Hwang;Wonhee Lee;Yoonseok Lee
    • Journal of Animal Science and Technology
    • /
    • v.66 no.4
    • /
    • pp.781-791
    • /
    • 2024
  • Bovine viral diarrhea (BVD) is a single-stranded, positive-sense ribonucleic acid (RNA) virus belonging to the genus Pestivirus of the Flaviviridae family. BVD frequently causes economic losses to farmers. Among bovine viral diarrhea virus (BVDV) strains, BVDV-1b is predominant and widespread in Hanwoo calves. Reverse-transcription polymerase chain reaction (RT-PCR) is an essential method for diagnosing BVDV-1b and has become the gold standard for diagnosis in the Republic of Korea. However, this diagnostic method is time-consuming and requires expensive equipment. Therefore, Clustered regularly interspaced short palindromic repeats-Cas (CRISPR-Cas) systems have been used for point-of-care (POC) testing of viruses. Developing a sensitive and specific method for POC testing of BVDV-1b would be advantageous for controlling the spread of infection. Thus, this study aimed to develop a novel nucleic acid detection method using the CRISPR-Cas13 system for POC testing of BVDV-1b. The sequence of the BVD virus was extracted from National Center for Biotechnology Information (NC_001461.1), and the 5' untranslated region, commonly used for detection, was selected. CRISPR RNA (crRNA) was designed using the Cas13 design program and optimized for the expression and purification of the LwCas13a protein. Madin Darby bovine kidney (MDBK) cells were infected with BVDV-1b, incubated, and the viral RNA was extracted. To enable POC viral detection, the compatibility of the CRISPR-Cas13 system was verified with a paper-based strip through collateral cleavage activity. Finally, a colorimetric assay was used to evaluate the detection of BVDV-1b by combining the previously obtained crRNA and Cas13a protein on a paper strip. In conclusion, the CRISPR-Cas13 system is highly sensitive, specific, and capable of nucleic acid detection, making it an optimal system for the early point-of-care testing of BVDV-1b.

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

Facile and Effective Detection of Vitamin C on a Paper Based Kit (종이기반 소수성 채널에서의 효율적이고 간편한 비타민 C의 검출기술 개발)

  • Hwang, Jangsun;Seo, Youngmin;Choi, Jonghoon
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2016
  • Recently paper based diagnostic kits have drawn great interest in the point-of-care testing market (POCT). The paper based detection systems provide inexpensive, rapid and safe analyses for disease markers and/or pathogens. Vitamin C (i.e., ascorbic acid) regulates body's immune system as an antioxidant agent. Humans, however, do not have enough amounts of enzymes involved in the synthesis of vitamin C that it is required to be obtained from their diets (e.g., beverages and/or supplements). Here, we have prepared a paper based kit to detect the concentration of Vitamin C presented in commercially available beverages. The evaluation provides the fast, simple and accurate results for detecting Vitamin C in the prepared paper based kit.

Recent Advances in a Microfluidic Paper-based Analytical Devices and its Point of Care Testing Applications (종이기반 미세유체 분석소자를 활용한 현장검사 기술과 그 응용)

  • Yoo, Yong Kyoung;Kim, Cheonjung;Lee, Junwoo;Lee, Jeong Hoon
    • Ceramist
    • /
    • v.21 no.3
    • /
    • pp.293-301
    • /
    • 2018
  • Paper-based analytical devices (${\mu}PAD$) are highly advantageous for portable diagnostic systems owing to their low costs and ease of use. ${\mu}PADs$ are considered as the best candidates for realizing the World Health Organization (WHO) ASSURED criteria: affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end users. However, they have several limitations such as low sensitivity and accuracy. This article reports a mini review for a micro-fluidic paper-based analytical devices (${\mu}PAD$), especially for addressing low sensitivity and accuracy issues.

Performances of Point-of-care Testing Systems for HDL Cholesterol

  • Chae, Woo-Churl;Cho, Jeoung-Hwan;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.201-204
    • /
    • 2003
  • Plasma lipoproteins transporting cholesterol through blood vessels are divided into three major classes, VLDL, LDL, and HDL. The ratio of HDL cholesterol over the total can be used as an indicator for prognosis of coronary artery diseases. In this study, we have developed two analytical systems for %HDL cholesterol with different flow modes toward gravity and analyzed them for their characteristics and performances.

  • PDF

Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

  • Jang, Yeong-Uk;Kim, Su-Nam;Cho, Hye-Jung;Sun, Yong-Han;Shim, So-Yeon;Son, Dong-Woo;Park, Pil-Whan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.301-309
    • /
    • 2011
  • Purpose: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). Methods: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. Results: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. Conclusion: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.