• Title/Summary/Keyword: point sampling

Search Result 821, Processing Time 0.03 seconds

A Case Study Stormwater Treatment by Channel-Type Wetland Constructed on the Flood Plane of the Stream (하천 고수부지에 설치한 수로형 인공습지에 의한 강우 유출수 처리에 관한 연구)

  • Kim, Piljoo;Han, Euilyung;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.80-89
    • /
    • 2017
  • Researches about NPS(Non-point Pollution Source) reduction have been widely carried out in recent years. A pilot channel-type constructed wetland (wet swale) was constructed in Rongyin area to treat stormwater generated from a green house agro-land of 22.7 ha. From 2006 to 2008, monitoring was conducted to evaluate its performance on the removal effect for organic pollutants as well as nutrients. Totally, sampling trips of 17 rainfall events were made and they covered most types of storm events in Korea. The channel-type constructed wetland have average removal efficiencies of 78.3~92.0%, 56.4~66.1%, 28.2~45.5% and 50.6~66.4% for SS, COD, TN and TP, respectively. According to four methods for estimating the removal efficiency, the average efficiencies of TSS, COD, TN and TP are 86.0%, 60.1%, 30.1% and 53.5%, respectively. From 2006 to 2008, annual efficiency improved due to infiltration potential increase. It was found that most of the pollutants removed in this channel type of wetland was particulate solids bound pollutants, which is assumed fact that it lacks of physico-chemical treatment conditions which are commonly observed in the retention type of constructed wetlands.

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.

Study of Particle Emission Contour Construction & Characteristics and Reduction Efficiency of Exhaust-Treatment System of Diesel Engine (승용 디젤 엔진의 후처리 시스템 적용에 따른 나노입자 배출 맵 구축 및 저감특성에 관한 연구)

  • Ko, A-Hyun;Hwang, In-Goo;Myung, Cha-Lee;Park, Sim-Soo;Choi, Hoi-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.755-760
    • /
    • 2010
  • In this study, we mainly focused on the PM (Particulate Matter) emission characteristics of a diesel engine. To analyze particle behavior in the tail-pipe, particle emission was measured on the engine-out (downstream of turbocharger), each upstream and downstream both of DOC (Diesel Oxidation Catalyst) and DPF (Diesel Particulate Filter). Moreover, particle emission contours on each sampling point were constructed. The reduction efficiency of particle number concentration and mass through the DOC and DPF was studied. Parameters such as EGR (Exhaust Gas Recirculation) and the main injection timing were varied in part load conditions and evaluated using the engine-out emissions. The DMS500 (Differential Mobility Spectrometer) was used as a particle measurement instrument that can measure particle concentrations from 5 nm to 1000 nm. Nano-particles of sizes less than 30 nm were reduced by oxidation or coagulated with solid particles in the tail-pipe and DOC. The DPF has a very high filtration efficiency over all operating conditions except during natural regeneration of DPF.

Performance of High Temperature Filter System for Radioactive Waste Vitrification Plant (방사성폐기물 유리화 플랜트 고온여과시스템의 성능 특성)

  • Seung-Chul, Park;Tae-Won, Hwang;Sang-Woon, Shin;Jong-Hyun, Ha;Hey-Suk, Kim;So-Jin, Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Important operation parameters and performance of a high temperature ceramic candle filter system were evaluated through a series of demonstration tests at a pilot-scale vitrification plant. At the initial period of each test, due to the growth of dust cake on the surface of ceramic candles, the pressure drop across the filter media increased sharply. After that it became stable to a certain range and varied continuously proportion to the face velocity of off-gas. On the contrary, at the initial period of each test, the permeability of filter element decreased rapidly and then it became stable. Back flushing of the filter system was effective under the back flushing air pressure range of 3∼5 bar. Based on the dust concentrations measured by iso-kinetic dust sampling at the inlet and outlet point of HTF, the dust collection efficiency of HTF evaluated. The result met the designed performance value of 99.9%. During the demonstration tests including a hundred hour long test, no specific failure or problem affecting the performance of HTF system were observed.

  • PDF

Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation (화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법)

  • Kim, Bum-Shin;Song, Gee-Wook;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.563-569
    • /
    • 2012
  • The superheater and reheater tubes of a heavy-load fossil power plant boiler can be damaged by overheating, and therefore, the degree of overheating is assessed by measuring the oxide scale thickness inside the tube during outages. The tube temperature prediction from the oxide scale thickness measurement is necessarily accompanied by destructive tube sampling, and the result of tube temperature prediction cannot be expected to be accurate unless the selection of the overheated point is precise and the initial-operation tube temperature has been obtained. In contrast, if the tube temperature is to be predicted analytically, considerable effort (to carry out the analysis of combustion, radiation, convection heat transfer, and turbulence fluid dynamics of the gas outside the tube) is required. In addition, in the case of analytical tube temperature prediction, load changes, variations in the fuel composition, and operation mode changes are hardly considered, thus impeding the continuous monitoring of the tube temperature. This paper proposes a method for the short-term prediction of tube temperature; the method involves the use of boiler operation information and flow-network-analysis-based tube heat flux. This method can help in high-temperaturedamage monitoring when it is integrated with a practical tube-damage-assessment method such as the Larson-Miller Parameter.

A Study on the Improvement of Dairy Rousing Systems in Kore (한국의 낙농시설 개선에 관한 연구)

  • Kim, Moon-Ki;Koh, Chae-Koon;Kim, H. U.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.31-43
    • /
    • 1982
  • Engineering phase of dairy housing systems has close connection with the milk produc- tivity of dairy cattle, the quality of milk, extension of dairy production systems, labor- saving in management of dairy cattle and the like. Moreover, the rate of investment of dairy housing facilities is of relatively high level, However, there has been almost no research effort for the improvement of engineering aspects of dairy housing systems in Korea. The purpose of this study is to find out general engineering problems and to recomm- end the improvement in dairy housing systems in Korea. Field survey by means of questionaire, direct measurements, taking pictures and sketching was conducted to get necessary information for the study. Kyung-ki Do region was firstly chosen for sampling area since it has included more than half of the number of dairy farms of the whole country. The results obtained are summarized as follows: 1. In overall dairy farm layout, the dwellings of workers were ignored in the light of sanitary environment 2. The layout of stalls in a dairy barn belongs mostly to the type of double-row face-out, which is compatible with the emphasis of manure disposal activities. 3. While the width and length of stalls were sufficiently close to the standard dimension, the width of mangers was much less than the standard dimension. 4. The width and depth of manure gutters and the width of working alleys were much. less than the standard dimension. 5. The mooring equipment was mostly in the classes of chain or rope. The watering equipment was not facilitated independantly except the one cese of using watercup. 6. The bucket milkers with one or two bucket milkers with the capacity of two cattles. each were used as milking equipment in most dairy farms. 7. There were only few milk rooms independently spaced from other space, in which the arrangement of milking equipment was much less than the standard condition. 8. The lounging ground area was averaged to be sufficient for the activity of dairy herd. 9. Silos for silage used during winter consisted of mostly bunker silos, trench silos and underground vertical silos. Ordinary vertical silos were considered for the farmers to be inconvenient for the labor saving. 10. From the view point of heat conservation and moisture removal within the dairy barns, windows were not flexible for the easy ventilation and ceiling part was not adequate for temperatur maintenance. 11. Waste treatment and disposal systems were not provided with most dairy farms, therefore the livestock waste pollution problems would be serious in the near future.

  • PDF

A study on the self-evaluation of job performance and creativity of dental hygienists (치과위생사 직무와 개인의 창의성에 의한 자기평가 연구)

  • Hong, Sun-Hwa;Goo, Kyong-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.6
    • /
    • pp.1037-1048
    • /
    • 2010
  • Objectives : The awareness of health care need increasing attention from the public along with changing professional human-resources activity. As there are increasing social demand for the roles and professionalism of dental hygienists, the purpose of this study was to examine the job performance, creativity and organizational climate of dental hygienists by their own self-diagnostic evaluation in an attempt to help enhance their work ability. Methods : According to the data released as August 2008 by the Dental Association and public health centers in Gwangju, 735 dental hygienists worked at 425 dental clinics. The subjects in this study were 156 dental hygienists at 85 dental clinics who were selected by proportionate sampling method from among the dental hygienists. After an interview survey was conducted in person, the answer sheets from 132 respondents were analyzed except 24 incomplete ones. The questionnaire used in this study consisted of 49 items. A five-point Likert scale was used and SPSS 12.0 program was analyzed the data. Results : 1. As a result of checking the types of works, treatment cooperation(54%), and oral health education often(45%), They weren't responsible for preventive treatment(42%). 2. When they made a self-diagnostic evaluation of creativity and organizational climate, they put the highest value on their autonomy(2.21), followed by positive attitude(2.10). Out of seven organizational climate, challenging spirits(2.81) ranked highest, followed by reliability(2.66). 3. Major management eopmubyeol individual creativity compared with three business relationships and a positive attitude in the case of the high group received oral health education and care management services in a group doing the most was General office work and office assistance work in the medical assistance group that was doing business primarily. 4. In the relationship between self-assesment score and three performance duties, Positive difference was noted in the group with positive attitude and elevated autonomy in terms of performing oral health education. Conclusions : As a result, individual creativity and organization of the atmosphere, each detail, through analysis of the self-assessment model, developed guide on the investigation by doing a dental hygienist, a unique business promotion and Enlargement of the study suggested the need to be considered is.

Degradation Behavior of Endocrine Disrupter Bisphenol-A in the Lake and Stream (호소 및 하천에서 환경호르몬 Bisphenol-A의 분해거동에 관한 연구)

  • Kang, Ho;Shin, Kyung-Sook;Kim, Sun-Ki;Jin, Chang-Sook
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.1
    • /
    • pp.59-69
    • /
    • 2001
  • Among the biodegradability tests, TOC-HANDAI and OECD method were utilized to examine the degree of biodegradation of endocrine disruptors, Bisphenol A (BPA) and Nonylphenol. Both methods used natural water microcosms and measured their biodegrada-bilities of BPA and Nonylphenol, in terms of TOC or DOC degradation with time for 28 days. Biodegradabilities for BPA, 73-78% with TOC-HANDAI method and 77-81% with OECD method were obtained respectively at the end of experiment. There was no difference in BPA degradation between two methods. BPA degradation was described by two distinct first order decay rates (k$_1$ and k$_2$) which could be separated by a simple visual fitting. Most of the initial decay reaction accelerated within 1-7 days with k$_1$of 0.24-0.34 $day^{-1}$. And the following another long term first order decay coefficient (k$_2$) showed 0.02-0.05 day$^{-1}$ with much flat slope. About 20-25% of initial BPA remained at the end of experiment. It suggests that the remaining TOC components in BPA biodegradation considered to be refractory metabolites of BPA. Nonylphenol at each sampling point was appeared to be mineralized 20-48% of initial TOC concentration. Consequently Nonylphenol seems more recalcitrant against biodegradation. BPA was not detected in the detection limit of ppb in the watershed of Daechung reservoir and Kum river. However 25 ppb concentration of BPA was detected at the influent of industrial wastewater treatment plant in Taejon.

  • PDF

Suicide Related Indicators and Trends in Korea in 2018 (2018년 자살 관련 지표들과 추이)

  • Lee, Doo Woong;Kwon, Junhyun;Yang, Jieun;Ju, Yeong Jun;Park, Eun-Cheol;Jang, Sung-In
    • Health Policy and Management
    • /
    • v.30 no.1
    • /
    • pp.112-119
    • /
    • 2020
  • Suicide has been a long-standing problem for global public health, along with almost 800,000 deaths from suicide worldwide in 2016, accounting for 1.4% of all deaths. South Korea was ranked first in suicide mortality in 2018 among countries in the Organization for Economic Cooperation and Development. This study aimed to suggest up-to-date information about suicide-related indicators such as the rate of suicidal ideation, suicide attempt, and suicide death, and its trends by applying sampling weight to make it nationally representative. In this study, we used the data sources: Korea National Health and Nutrition Examination (KNHANES, '07-13, '15-18), Korean Community Health Survey (KCHS, '08-09, '13, '17), Korean Wealth Panel Study (KOWEPS, '12-18), Korea Health Panel Survey (KHP, '10-13), and Statistics Korea (1983-2017). The rate of suicidal ideation as recent year was 4.73% (KNHANES, '17), 6.96% (KCHS, '17), 2.29% (KOWEPS, '18), and 5.39% (KHP, '13). That of suicide attempt as recent year was 0.51% (KNHANES, '18), 0.32% (KCHS, '17), and 0.15% (KOWEPS, '18). Annual percentage change (APC) of suicidal ideation was -15.4% (KNHANES, '07-13, '15, '17), -2.5% (KCHS, '08-09, '13, '17), -10.8% (KOWEPS, '12-18), and -10.9% (KHP, '10-13). APC of suicide attempt was -4.4% (KNHANES, '07-13, '15-18), -4.4% (KCHS, '08-09, '13, '17), and -13.6% (KOWEPS, '12-18). APC of death by intentional self-harm was -1.25% (Statistics Korea, '07-18). All suicide-related indicators were found to be decreasing in the overall from 2009. Individuals with lower income level were more likely to experience suicidal ideation and suicide attempts. Even though suicide rate had been continuously decreasing from its highest point in 2011 (suicide rate: 31.7 per 100,000 population) to 2017 (suicide rate: 24.3 per 100,000 population), it increased again in 2018 (suicide rate: 26.6 per 100,000 population). This information would be grounded on policy implementation for suicide prevention, thus continuous data observation is necessary.

A study of illumination of dental laboratories (치과 기공실의 조명에 관한 실태 조사 연구)

  • Lee, Hyo-Jung;Choi, Jong-In;Kim, Sung-Sook;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.289-298
    • /
    • 2014
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental laboratories in order to distinguish colors for esthetic dentistry. Materials and Methods: A total of forty-eight local dental laboratories were selected for sampling a) luminous intensity and b) color temperature. We measured the luminous intensity and the color temperature on a center point of porcelain table with lux meter and color meter respectively. The measurements were performed twice, once on a clear day and on a cloudy day between 12 pm and 2 pm (day light and artificial illumination) and between 7 pm and 10 pm (artificial illumination only). Results: The results obtained were as follows. 1. The average luminous intensity in dental laboratories lighting was 1871 lx, and 67% of dental laboratories had luminous intensity greater than 1600 lx, which was appropriate for operations related to colors, while 33% of dental laboratories had in sufficient lighting for appropriate luminous intensity. 2. The average color temperature in dental laboratories lighting was 6506 K, which was inappropriate for operations related to color. None of the dental laboratories had a color temperature range of 5000 - 5500 K, which is appropriate for operations related to colors. 3. Between daytime and nighttime, also between clear day and cloudy day, the average luminous intensity and color temperature in dental laboratories were not significantly different. Conclusion: Illumination in most dental laboratories selected in this study was inappropriate for operations related to color.