• Title/Summary/Keyword: plate behavior

Search Result 1,989, Processing Time 0.032 seconds

Characteristics of Anchorage Length for Reinforced Concrete Beam Strengthened by CFRP Plate (탄소섬유보강판으로 보강된 철근콘크리트 보의 정착길이 특성)

  • 한상훈;최만용;조홍동;박중열;황선일;권용길
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.405-410
    • /
    • 2002
  • This paper deals with the flexural behavior of RC hems strengthened with CFRP plate and the estimation on anchorage length of CFRP Plate. Experimental variables included concrete strength, reinforcement ratio, cover thickness of concrete and length ratio of CFRP plate for a pure span. A failure load, failure mode, deflection and strain response at different distances from a cut-off point of CFRP plate were observed and anchorage length was determined through strain distribution of CFRP plate. Herein, anchorage length is defined the length between CFRP plate end and the beginning point of full composite behavior. Also, the anchorage length observed from the experiment was compared with Nguyen's equation and BS specification.

  • PDF

A Study on the Nonlinear Behavior of Plate under Thrust (면내압축하중을 받는 선체판의 비선형거동에 관한 연구)

  • 고재용
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1996.09a
    • /
    • pp.95-110
    • /
    • 1996
  • High Tensile Steel enables to reduce the plate thickness comparing to the case when Mild Steel is used. From the economical view point this is very preferable since the reduction in the hull weight. However to use the High Tensile Steel effectively the plate thickness may become thin so that the occurrence of buckling is inevitable and design allowing plate buckling may be necessary. If the inplane stiffness of the plating decreases due to buckling, buckling may be necessary. If the inplane stiffness of the plating decreases due to buckling the flexural rigidity of the cross section of a ship's hull also decreases. this may lead to excessive deflection of the hull girder under longitudinal bending. In these cases a precise estimation of plate's behavior after buckling is necessary and nonlinear analysis of isolated and stiffened plates is required for structural system analysis. In this connection this paper discusses nonlinear behaviour of thin plate under thrust. Based on the analytical method elastic large deflection analysis of isolated plate is perform and simple expression are derived to evaluate the inplane rigidity of plates subjected to uniaxial compression.

  • PDF

Study on Metal Plate Connections and Plywood Gusset Plate Connections for Light-Frame Wood Truss Tension Joint (목재 트러스 접합부의 toothed metal plate 접합과 plywood gusset plate 접합에 관한 연구)

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.46-50
    • /
    • 1992
  • 본 연구는 잣나무 간벌재를 이용한 plywood gusset plate 접합과 toothed metal plate 접합에 대하여 인장력을 가해 조사하였다. plywood gusset plate 접합에 있어서는 합판과 부재 사이를 상온 경화제(초산 비닐 수지)로 접착한 후 6d 못으로 접합한 형태와 단지 합판만을 사용한 형태의 plywood gusset plate 접합 사이의 기계적 특성 차이를 조사했다. toothed metal plate 접합은 plywood gusset plate 접합보다 인장력에서 좋은 behavior를 보였다. 또한 접착제를 가한 plywood gusset plate 접합은 접합제를 가하지 않은 형태보다 큰 하중 지지력을 보였다.

  • PDF

Cut out effect on nonlinear post-buckling behavior of FG-CNTRC micro plate subjected to magnetic field via FSDT

  • Jamali, M.;Shojaee, T.;Mohammadi, B.;Kolahchi, R.
    • Advances in nano research
    • /
    • v.7 no.6
    • /
    • pp.405-417
    • /
    • 2019
  • This research is devoted to study post-buckling analysis of functionally graded carbon nanotubes reinforced composite (FG-CNTRC) micro plate with cut out subjected to magnetic field and resting on elastic medium. The basic formulation of plate is based on first order shear deformation theory (FSDT) and the material properties of FG-CNTRCs are presumed to be changed through the thickness direction, and are assumed based on rule of mixture; moreover, nonlocal Eringen's theory is applied to consider the size-dependent effect. It is considered that the system is embedded in elastic medium and subjected to longitudinal magnetic field. Energy approach, domain decomposition and Rayleigh-Ritz methods in conjunction with Newton-Raphson iterative technique are employed to trace the post-buckling paths of FG-CNTRC micro cut out plate. The influence of some important parameters such as small scale effect, cut out dimension, different types of FG distributions of CNTs, volume fraction of CNTs, aspect ratio of plate, magnitude of magnetic field, elastic medium and biaxial load on the post-buckling behavior of system are calculated. With respect to results, it is concluded that the aspect ratio and length of square cut out have negative effect on post-buckling response of micro composite plate. Furthermore, existence of CNTs in system causes improvement in the post-buckling behavior of plate and different distributions of CNTs in plate have diverse response. Meanwhile, nonlocal parameter and biaxial compression load on the plate has negative effect on post-buckling response. In addition, imposing magnetic field increases the post-buckling load of the microstructure.

Coupled testing-modeling approach to ultimate state computation of steel structure with connections for statics and dynamics

  • Imamovic, Ismar;Ibrahimbegovic, Adnan;Mesic, Esad
    • Coupled systems mechanics
    • /
    • v.7 no.5
    • /
    • pp.555-581
    • /
    • 2018
  • The moment-resistant steel frames are frequently used as a load-bearing structure of buildings. Global response of a moment-resistant frame structure strongly depends on connections behavior, which can significantly influence the response and load-bearing capacity of a steel frame structure. The analysis of a steel frame with included joints behavior is the main focus of this work. In particular, we analyze the behavior of two connection types through experimental tests, and we propose numerical beam model capable of representing connection behavior. The six experimental tests, under monotonic and cyclic loading, are performed for two different types of structural connections: end plate connection with an extended plate and end plate connection. The proposed damage-plasticity model of Reissner beam is able to capture both hardening and softening response under monotonic and cyclic loading. This model has 18 constitutive parameters, whose identification requires an elaborate procedure, which we illustrate in this work. We also present appropriate loading program and arrangement of measuring equipment, which is crucial for successful identification of constitutive parameters. Finally, throughout several practical examples, we illustrate that the steel structure connections are very important for correct prediction of the global steel frame structure response.

Shear response of lean duplex stainless steel plate girders

  • Armoosh, Salam R.;Khalim, A.R.;Mahmood, Akram Sh.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.6
    • /
    • pp.1267-1281
    • /
    • 2015
  • Carbon steel plate girders have been used on a large scale in the building industry. Nowadays, Lean Duplex Stainless Steel (LDSS) plate girders are gaining popularity as they possess greater strength and are more impervious to corrosion than those that are constructed from carbon steel. Regardless of their popularity, there is very limited information with regards to their shear behavior. In this paper, the non-linear finite element analysis was employed to investigate the shear behavior of LDSS plate girders. Parameters considered were the web thickness, the flange width, and the girders aspect ratio. The analysis revealed that although the shear behavior of the LDSS girders was no different from that of carbon steel plate girders, it had obviously been affected by the non-linearity of the material. Furthermore, the selected parameters were found to pronounce effect on the shear capacity of the LDSS girders. That is, the shear capacity increased considerably with web thickness, and increased slightly with flange width. However, it was reduced as the aspect ratio increased. Comparisons between the finite element analysis failure loads and those predicted by the current European Code of Practice revealed that the latter underestimated the shear strength of the LDSS plate girders.

Parametric study using finite element simulation for low cycle fatigue behavior of end plate moment connection

  • Lim, Chemin;Choi, Wonchang;Sumner, Emmett A.
    • Steel and Composite Structures
    • /
    • v.14 no.1
    • /
    • pp.57-71
    • /
    • 2013
  • The prediction of the low cycle fatigue (LCF) life of beam-column connections requires an LCF model that is developed using specific geometric information. The beam-column connection has several geometric variables, and changes in these variables must be taken into account to ensure sufficient robustness of the design. Previous research has verified that the finite element model (FEM) can be used to simulate LCF behavior at the end plate moment connection (EPMC). Three critical parameters, i.e., end plate thickness, beam flange thickness, and bolt distance, have been selected for this study to determine the geometric effects on LCF behavior. Seven FEMs for different geometries have been developed using these three critical parameters. The finite element analysis results have led to the development of a modified LCF model for the critical parameter groups.

Inelastic behavior of RC shear wall and steel girder shear connection on reinforcement details (보강상세에 따른 RC 전단벽과 강재 보 전단접합부의 비탄성 거동)

  • Song, Han-Beom;Lee, Jung-Han;Yang, Won-Jik;Kang, Dae-Eon;Lee, Kyung-Hwun;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.138-141
    • /
    • 2006
  • Shear wall-frame system is one of the most, if not the most, popular system for resisting lateral loads. The core is the primary lateral load-resisting systems, the perimeter frame is designed for gravity loads, and the connection between perimeter frame and core is generally a shear connection. Specially, single plate shear connection have gained considerable popularity in recent years due to their ease of fabrication and erection. Single plate shear connection should be designed to satisfy the dual criteria of shear strength and rotational ductility. An experimental program was undertaken to evaluate seismic behavior of single plate shear connection. The main test variable is the reinforcing detail of connection. Through the experimental program, the cyclic behavior of typical and reinforcing single plate shear connection was established.

  • PDF

Local Buckling Behavior of Pultruded Structural Flexural Members (펄트루젼 구조용 휨부재의 국부좌굴 거동)

  • 정재호;윤순종
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.147-151
    • /
    • 2003
  • In this study, we discussed the local buckling behavior of pultruded structural flexural members. Previous works were briefly reviewed and the local buckling behavior of orthotropic box-shape flexural members was discussed. The simplified form of equation for finding the width ratio of plate element of box-shape flexural members in which all plate components buckle simultaneously was proposed and the macro flow-chart for finding local buckling strength of pultruded flexural members was also suggested. To establish the design guide line for the local buckling of pultruded flexural members, further studies need to be performed as follows; the simplified form of solutions for finding the minimum buckling coefficient of orthotropic plate with various loading and boundary conditions including rotationally restrained boundary conditions, the simplified form of equation for calculating the coefficient of restraint provided by the adjacent plate elements.

  • PDF

An Experimental Study on Strengthened Behavior of Reinforced Concrete Columns with Steel Plate (강판 보강된 철근 콘크리트 기둥의 거동에 대한 실험적 연구)

  • 박주현;홍기섭;홍영균;신영수;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.557-564
    • /
    • 1997
  • This research is aimed to evaluate the effects of repair conditions, axial load intensities and the enlargement of cross sections after strengthening with steel plate and on the structural behavior of the reinforced concrete columns subjected to axial and lateral loadings. 6 columns were tested under uniform axial compression and concentrated load at the midspan until failiure occurs. As test results, It has been found that the amount of grout bar and the condition of strengthening significantly affect the behavior or reinforced concrete column with steel plate and grout 4 bar (C-G4S2 serise) and enlarged reinforced concrete column with steel plate and grout 8 bar (C-G8S2 serise) are increased to 1000% and 1200% in comparison of those of unstrengthened reinforced concrete columns, respectively

  • PDF