• 제목/요약/키워드: plastic rotation

검색결과 352건 처리시간 0.024초

하악전돌증의 술후 동태에 관한 두부계측학적 분석 (CEPHALOMETRIC ANALYSIS OF POSTSURGICAL BEHAVIOR OF MANDIBULAR PROGNATHISM)

  • 김종렬;김태규;정인교;양동규;박수병;손우성;이병태
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권2호
    • /
    • pp.123-128
    • /
    • 1993
  • For the purpose of studying postsurgical stability of mandibular prognathism, 18 patients(8 men and 10 women) were selected who underwent sagittal split ramus osteotomy and lateral cephalograms taken preoperatively, immediate postoperatively, and over 6-month follow-up were traced and analysed. The following results were obtained. 1. Average magnitude of setback vas 11.0mm, and aberage relapse was 3.0mm, so the rate of relapse was 27%. 2. Magnitude of mandibular setback contributed to relapse. 3. The patients of less than 10mm setback showed average 10% of relapse rate, and it was of little clinical significance. 4. Proper detachment of pterygomasseteric sling prevention of clockwise rotation of proximal segment and rigid fixation are recommended for the better postoperative stability.

  • PDF

하중-균열열림변위를 이용한 굽힘하중이 작용하는 원주방향 관통균열 배관의 새로운 J 실험법 (New J Testing Method Using Load-COD Curve for Circumferential Through-Wall Cracked Pipes under Bending)

  • 허남수;김윤재;김영진
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.60-65
    • /
    • 2006
  • The present paper provides experimental J estimation equation for the circumferential through-wall cracked pipe under four-point bending, based on the load-crack opening displacement (COD) record. Based on the limit analysis and the kinematically admissible rigid-body rotation field, the plastic ${\eta}$-factor for the load-COD record is derived and is compared with that for the load-load line displacement record. Comparison with the J results from detailed elastic-plastic finite element (FE) analysis shows that the proposed method based on the load-COD record provides reliable J estimates even for shallow cracks, whereas the conventional approach based on the load-load line displacement record gives erroneous results for shallow cracks. Thus, the proposed J estimation method could be recommended for testing the circumferential through-wall cracked pipe, particularly with shallow cracks.

비틀림 모멘트가 부가되는 일체형 중공 드라이브 샤프트의 구조 안정성 분석 (Investigation of Structural Safety of Monobloc Tubular Drive Shaft Subjected to Torque)

  • 국대선;안동규;이호진;정종훈
    • 한국정밀공학회지
    • /
    • 제32권12호
    • /
    • pp.1073-1080
    • /
    • 2015
  • A drive shaft is used to transmit torque and rotation through the connection of components of a drive train. Recently, a monobloc drive shaft without welding regions is developed to improve the safety of the drive shaft. The drive shaft bears the shear stress induced by torque. The objective of this paper is to investigate into the structural safety of a monobloc tubular drive shaft subjected to torque. Elasto-plastic finite element (FE) analysis is performed to estimate the deformation behavior of the drive shaft and stress-strain distribution in the drive shaft. Several techniques are used to create finite element (FE) model of the monobloc tubular drive shaft subjected to torque. Through the comparison of the results of FE analyses with those of experiments from the viewpoint of rotational angle, appropriate correction coefficients for different load conditions are estimated. The safety of the tubular drive shaft is examined using the results of FE analyses for different load conditions. Finally, it is noted that the designed tubular drive shaft has a sufficient structural safety.

등통로각압축공정을 통한 결정립의 균질한 초미세립화에 대한 고찰 (Evaluation of Homogeneous Ultra-fine Grain Refinements via Equal Channel Angler Pressing Process)

  • 김우열;이학현;서승재;이재근;윤태식;김형섭
    • 소성∙가공
    • /
    • 제27권4호
    • /
    • pp.222-226
    • /
    • 2018
  • Severe plastic deformation (SPD) is a promising method for drastically enhancing the mechanical properties of the materials by grain refinement of metallic materials. However, inhomogeneous deformation during the SPD process results in the inhomogeneous microstructure of the SPD-processed material. We manufactured cylindrical copper specimens of 42 mm in diameter with ultrafine grains (UFG) using an equal channel angular pressing (ECAP) to figure out the relationship between homogeneous microstructure and the number of the processing passes. Two specimens, which are ECAP-processed 4 times (4pass) and 6 times (6pass) each with Route Bc, are prepared for comparison of mechanical properties and microstructure. The results show that the mechanical properties of the two specimens (4pass and 6pass) are similar. Moreover, both the specimens show highly enhanced mechanical properties. The 4pass specimen, however, shows inhomogeneity in hardness distribution, while the 6pass specimen shows a homogeneous distribution. Microstructure analysis reveals that the 4pass specimen has an inhomogeneous microstructure with incompletely refined grain structure. This inhomogeneity of the 4pass specimen could be explained by the circumferential rotation during ECAP process.

Botulinum toxin-A injection into the anterior belly of the digastric muscle for the prevention of post-operative open bite in class II malocclusions: a case report and literature review

  • Kang, Yei-Jin;Cha, Bong Kuen;Choi, Dong Soon;Jang, In San;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.17.1-17.5
    • /
    • 2019
  • Background: Class II malocclusion patients with hyperdivergent facial types are characterized by short mandibular body lengths and anterior open bite. Accordingly, the treatment for hyperdivergent skeletal class II malocclusion is a lengthening of the mandibular body length and a counterclockwise rotation of the mandible. To prevent post-operative relapse, botulinum toxin-A (BTX-A) injection can be a retention modality. Case presentation: A class II open-bite patient received BTX-A injection to the anterior belly of her digastric muscle for the prevention of post-operative relapse. The relapse was evaluated via a clinical examination and a lateral cephalometric radiograph after the completion of post-surgical orthodontic treatment. The patient showed stable occlusion without any signs of relapse at 15 months post-operatively. Conclusion: In this case presentation, a single injection into the anterior belly of the digastric muscle was sufficient for the prevention of post-operative open bite.

X선 회절과 유한요소법을 이용한 터빈 블레이드의 파괴기구에 관한 연구 (A Study on the Failure Mechanism of Turbine Blade using X-Ray Diffraction and FEM)

  • 김성웅;홍순혁;전형용;조석수;주원식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.258-265
    • /
    • 2001
  • Turbine blade is subject to force of three type ; torsional force by torsion-mount, centrifugal force by rotation of rotor and cyclic bending force by steam pressure. Cyclic bending force of them is main factor on fatigue fracture. In the X-ray diffraction method, the change in the values related to plastic deformation and residual stress near the fracture surface mat be determined, and information of internal structure of material can be obtained. Therefore, to find a fracture mechanism of torsion-mounted blade in nuclear plant, based on the information from the fracture surface obtained by fatigue test, the correlation of X-ray parameter and fracture mechanics parameter was determined, and then the load applied to actual broken turbine blade parts was predicted. Failure analysis is performed by finite element method and Goodman diagram on torsion-mounted blade.

  • PDF

Performance Evaluation of CT Using Visible Scintillation Light

  • Kodama, Kiyoyuki;Hashimoto, Masatoshi;Hanada, Takashi;Suzuki, Tamotsu;Ide, Tatsuya;Maruyama, Koichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.464-467
    • /
    • 2002
  • We propose the use of visible scintillation light for monitoring the X-ray CT in the gantry of a diagnostic CT for its performance test and maintenance works. We placed a disk of bare plastic scintillator disk in the gantry opening area of a helical X-ray CT. When we operated the CT, we could observe the emission of blue scintillation light from the scintillator in a dark room. Visible light was identified under all scanning conditions of diagnostic uses. As a result, we observed the direction and the spread of the incident X-ray in the scintillator. We also observed the change of the part of the scintillator where visible light was generated, and the move that took place associating with the rotation of the X-ray tube during one CT scan. On the basis of the observation, we examined the usefulness of the visible scintillation light as a convenient performance-evaluating tool as well as a maintenance tool of the CT.

  • PDF

Al6061-T6의 마찰교반용접 시 회전 Tool Pin 형상에 따른 기계적 특성 평가 (Mechanical Characteristic Evaluation by Spin Tool of Different Pin Shapes in Friction Stir Welding Al6061-T6)

  • 임병철;김대환;박상흡
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.345-349
    • /
    • 2014
  • In this study, an age-hardened 6061-T6 alloy sheet was used, which is commonly utilized for auto parts. The junction strength characteristics in relation to the stirring speed and welding speed were studied in accordance with the friction stir welding rotation of the tool pin. Micro hardness measurements of A type and B type pins, for a welding speed of 400 mm/min and a tool rotational speed 3000 rpm, were obtained as Hv104 and Hv111, respectively. For a welding speed of 200 mm/min and a tool rotational speed of 2000 rpm, we obtained Hv48 and Hv50 for A and B type pins, respectively. Microstructure observation showed that the stirring portion was fine and uniform, which occurred because of its plastic deformation. In the thermomechanically affected zone, partial recrystallization was present because of the plastic deformation. The crystal grains in the heat affected zone were coarsened due to the heat generated by friction stir welding.

두경부 재건에 융용한 두가지 도서형 피판 : 대흉근피판과 외측 승모근피판 (Versatile Two Island Flaps for Head and Neck Reconstruction)

  • 이혜경;신극선;김광문
    • 대한두경부종양학회지
    • /
    • 제7권2호
    • /
    • pp.92-98
    • /
    • 1991
  • Numerous mycoutaneous island flaps or free flaps have been used to reconstruct a defect which resulted from the wide resection of tumor mass in head and neck region. Since the curative resection of tumor usually include muscles and bones as well as skin and mucosa, the anatomical and functional restoration of the defect depend on which and what amount of tissues were provided to cover the defect; good aesthetic appearance subsequently follows the result. Furthermore, a simultaneous neck nodes dissection usually results in exposure of major neck vessels., which should be protected with sufficient padding. The ideal method to reconstruct a defect in the head and neck region requires a sufficient coverage by muscle layer with good vascularity, a wide arc of rotation, and minimization of donor site defect. The pectoralis major myocutaneous flap which was first decribed by Ariyan and lateral trapezius myocutaneous flap by Demergasso meet these criteria. We describe the use of these myocutaneous flaps in reconstruction of mandible and oral cavity.

  • PDF

The External Auricular Reconstruction with Inferior Based Retroauricular Flap Including the Posterior Auricular Artery

  • Choi, Jong Hwan;Ki, Sae Hwi
    • Archives of Reconstructive Microsurgery
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The external ear is a common area of trauma on the body prone to exposure of ultraviolet light, which can lead to skin cancer. Thus, variable techniques have been developed and used for reconstruction of the external ear. The aim of this study is to review the surgical method, its area of application, as well as advantages and pitfalls of reconstruction of the external ear with inferior based retroauricular flaps. Materials and Methods: Eight patients underwent external ear reconstruction with inferior based retroauricular flap for external ear defects in our institute from September 2012 to June 2015. According to the area of the defect, patients were classified as middle 1/3 (n=4), inferior 1/3 (n=2), superior auroculo-cephalic sulcus (n=1), and external auditory canal (n=1). Results: All of the flaps survived the operation and there was no marginal necrosis. Mean size of the defect was $2.8{\times}1.8cm$ and mean size of the retroauricular flap was $5{\times}2cm$. For insetting of the flap, a subcutaneous tunneling technique was used in 6 cases and rotation without subcutaneous tunneling was used in 2 cases. Transient paresthesia occurred in 3 cases. Two cases recovered within 3 months but one case did not recover until 6 months. Conclusion: The inferior based retroauricular flap is an available technique in external ear reconstruction with one stage operation.