• 제목/요약/키워드: plastic local buckling

검색결과 103건 처리시간 0.021초

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar;Anandavalli, N.;Madheswaran, C.K.;Lakshmanan, N.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.239-258
    • /
    • 2012
  • In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

Seismic behavior of thin-walled CFST pier-to-base connections with tube confined RC encasement

  • Xuanding Wang;Yue Liao;Jiepeng Liu;Ligui Yang;Xuhong Zhou
    • Steel and Composite Structures
    • /
    • 제50권2호
    • /
    • pp.217-235
    • /
    • 2024
  • Concrete-filled steel tubes (CFSTs) nowadays are widely used as the main parts of momentous structures, and its connection has gained increasing attention as the complexity in configuration and load transfer mechanism. This paper proposes a novel CFST pier-to-footing incorporating tube-confined RC encasement. Such an innovative approach offers several benefits, including expedited on-site assembly, effective confinement, and collision resistance and corrosion resistance. The seismic behavior of such CFST pier-to-footing connection was studied by testing eight specimens under quasi-static cyclic lateral load. In the experimental research, the influences on the seismic behavior and the order of plastic hinge formation were discussed in detail by changing the footing height, axial compression ratio, number and length of anchored bars, and type of confining tube. All the specimens showed sufficient ductility and energy dissipation, without significant strength degradation. There is no obvious failure in the confined footing, while local buckling can be found in the critical section of the pier. It suggests that the footing provides satisfactory strength protection for the connection.

종방향 영구지반변형에 의한 매설관로의 거동 특성 해석 (Response Analysis of Buried Pipelines Considering Longitudinal Permanent Ground Deformation)

  • 김태욱
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.184-191
    • /
    • 2000
  • In this research, a numerical model is developed for analysis of buried pipelines considering longitudinal permanent ground deformation(PGD) due to liquefaction induced lateral spreading. Buried pipelines and surrounding soil are medeled as continuous pipelines using the beam elements and a series of elasto-plastic springs uniformly distributed along the pipelines, respectively. Idealized various PGD patte군 based on the observation of PGD are used as a loading configuration and the length of the lateral spread zone is considered as a loading parameter. Numerical results are verified with other research results and efficient applicability of developed procedure is shown. Analyses are performed by varying different parameters such as PGD pattern, pipe diameter and pipe thickness. Results show that response of buried pipelines are more affected by pipe thickness than pipe diameter. Finally, the critical length of the lateral spread zone and the critical magnitude of PGD which cause yielding, local buckling or tension failure are proposed for the steel pipe which are normally used in Korea.

  • PDF

포물선형상의 성형성에 관한 유한요소해석 (Finite Element Analysis on Formability of Parabolic Shape)

  • 정상원;이경원
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.677-682
    • /
    • 2012
  • For the product with small diameter, long column, and parabolic shape, the forging formability of the high-carbon steel wire rod was investigated in this study. By using the three-dimensional finite element method, the formability of wire was reviewed by forming analysis for the desired parabolic shape of local part. Analysis results due to forging direction, forging velocity, friction coefficient and constraint location were also investigated. On the basis of these results, it is noted that the forging direction has the big influence when the product with long column is forged. As the forging velocity increases, buckling tends to be limited and formability of parabolic shape is improved. By constraining the lower parabolic shape part to suppress plastic strain, the effect depending on friction coefficient is not almost appeared. And good parabolic shape is obtained at the region of the forging velocity of more than 0.5 m/s.

Effect of stiffeners on failure analyses of optimally designed perforated steel beams

  • Erdal, Ferhat
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.183-201
    • /
    • 2016
  • Perforated steel beams can be optimised by increased beam depth and the moment of inertia combined with a reduced web thickness, favouring the use of original I-section beams. The designers are often confronted with situations where optimisation cannot be carried out effectively, taking account of the buckling risk at web posts, moment-shear transfers and local plastic deformations on the transverse holes of the openings. The purpose of this study is to suggest solutions for reducing these failure risks of tested optimal designed beams under applying loads in a self-reacting frame. The design method for the beams is the hunting search optimisation technique, and the design constraints are implemented from BS 5950 provisions. Therefore, I have aimed to explore the strengthening effects of reinforced openings with ring stiffeners, welded vertical simple plates on the web posts and horizontal plates around the openings on the ultimate load carrying capacities of optimally designed perforated steel beams. Test results have shown that compared to lateral stiffeners, ring and vertical stiffeners significantly increase the loadcarrying capacity of perforated steel beams.

On the large plastic deformation of tubular beams under impact loading

  • Wang, B.
    • Structural Engineering and Mechanics
    • /
    • 제3권5호
    • /
    • pp.463-474
    • /
    • 1995
  • When a tubular cantilever beam is loaded by a dynamic force applied transversely at its tip, the strain hardening of the material tends to increase the load carrying capacity and local buckling and cross-sectional overlization occurring in the tube section tends to reduce the moment carrying capacity and results in structural softening. A theoretical model is presented in this paper to analyze the deformation of a tubular beam in a dynamic response mode. Based on a large deflection analysis, the hardening/softening M-${\kappa}$ relationship is introduced. The main interest is on the curvature development history and the deformed configuration of the beam.

축압축력을 받는 원통형 축대칭 쉘구조의 거동에 관한 연구 (A Study on the Behavior of Cylindrical Shell Structure Subjected to Axial Compression)

  • 조현영;정진환;황상필
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.249-253
    • /
    • 1997
  • A numerical method for evaluating the equilibrium path of cylindrical shell subject to axial load and eccentrically axial load is presented. The effects of both material and geometric nonlinearities were also considered in the analysis. The nonlinear formulation was based on the total Lagrangian description and nonlinear equtions were solved by the Newton-Raphson method with load increment procedures. Degenerate shell elements with layered approach were employed for the analysis. The elasto-plastic deformation can be found in several examples and a large eccentricity of the axial load reduces the stress level at the time of the local buckling of the pipe considerably.

  • PDF

콘크리트 채움 U형 메가 합성보의 내진성능 평가 (Seismic Performance Evaluation of Concrete-filled U-shaped Mega Composite Beams)

  • 이철호;안재권;김대경;박지훈;이승환
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.111-122
    • /
    • 2017
  • 본 연구에서는 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보의 합성보통모멘트골조에 대한 적용성을 검토하였다. 대형 합성보의 실물대 내진성능실험에 대한 현실적 제약으로 인하여 작은 규모의 실험체에 대해 수행된 기존 실험결과의 분석과 수치해석연구의 보완을 통해 연구를 수행하였다. 이러한 형태의 합성보는 부모멘트 작용시의 웨브국부좌굴이 가장 중요하므로 선행 실물대 실험결과로부터 웨브의 판폭두께비와 층간변형능력 사이의 관계를 분석하였다. 그 결과, 25mm 두께의 U형 강재단면을 지닌 1900mm급의 대형 합성보라 하더라도 층간변위각 2% 이후 웨브국부좌굴을 경험하고 3% 이후 최대변형에 도달하는 것으로 확인되었다. 이는 합성보통모멘트골조의 요구조건을 상회하는 것으로 AISC 기준에 따른 웨브 판폭두께비 제한이 본 연구의 U형 단면에는 보수적임을 시사하기도 한다. 유한요소해석을 통해서는 합성보의 휨성능 및 웨브국부좌굴에 대한 수평스티프너의 영향을 분석하였다. 대형 합성보는 스티프너 보강과 관련없이 부모멘트 방향으로 공칭소성모멘트 이상의 휨성능을 발휘하였으며, 스티프너를 보강할 경우에는 웨브국부좌굴이 상당히 지연되는 긍정적인 효과가 있었다. 이상의 실험결과 분석 및 해석연구에 의하면 1900mm급의 춤이 깊은 콘크리트 채움 U형 메가 합성보는 합성보통모멘트골조에 보수적으로 적용가능한 것으로 판단된다.

편심이 고려된 강관-가셋트 접합부의 극한 내력 (A Study on the Ultimate Strength of Tube-Gusset Connection Considering Eccentricity)

  • 김우범
    • 한국강구조학회 논문집
    • /
    • 제13권2호
    • /
    • pp.201-210
    • /
    • 2001
  • 본 연구에서는 편심 축력을 받는 가셋트-강관 접합부의 극한 내력을 파악하기 위하여 실험 및 유한요소해석을 수행하였다. 가셋트-강관 접합부의 내력에 영향을 주는 요소는 강관의 직경, 가셋트판 길이, 축력과 횡력의 비, 횡력에 의한 편심 등으로 이들이 주재의 좌굴내력에 미치는 영향을 정량적으로 파악하여 접합부 강도식을 제안하였다. 특히 횡력에 의한 편심이 주재에 작용할 때 이를 설계식에 반영하기 위하여 횡력을 등가의 모멘트 및 편심 축력으로 대치한 수치 모형을 제시하였다. 결과적으로 접합부의 작용하는 외력을 주주재 축력, 모멘트, 편심 축력으로 분해하고 각 외력에 대한 독립적인 극한내력을 구한후 이들의 상관 관계식을 구함으로써 접합부 극한강도식을 제시하였다.

  • PDF

개선소성힌지해석과 SUMT를 이용한 평면 강골조의 연속최적설계 (Optimum Design of Plane Steel Frame Structures Using Refined Plastic Hinge Analysis and SUMT)

  • 윤영묵;강문명;이말숙
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.21-32
    • /
    • 2004
  • 본 연구에서는 다제약 설계변수를 갖는 비선형 문제를 무제약 최소화 문제로 전환하는 축차무제약 최소화기법(SUMT)과 효과적인 강골조의 2차비탄성해석 방법 중의 하나인 개선소성힌지해석 방법을 접목시킨 평면 강골조의 연속최적설계 모델 및 프로그램을 개발하였다. 최적설계를 위한 목적함수로는 강골조물을 구성하는 모든 부재의 중량 합을, 제약조건으로는 AISC-LRFD의 휨강도, 전단강도, 압축 및 인장강도, 국부좌굴 및 부재좌굴, 그리고 단면형상 등에 관한 설계기준을 사용하였다. 본 연구에서 개발한 연속최적설계 모델을 이용하여 여러 평면 강골조의 최적설계를 수행하였으며, 최적설계 견과로부터 개발한 연속최적설계 모델의 사용성, 타당성, 효율성 및 경제성 등을 검토하였다.