• Title/Summary/Keyword: plasma technique

Search Result 748, Processing Time 0.031 seconds

Low-temperature synthesis of graphene on nickel foil by microwave plasma chemical vapor deposition

  • Kim, Y.;Song, W.;Lee, S.Y.;Jung, W.;Kim, M.K.;Jeon, C.;Park, C.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.80-80
    • /
    • 2010
  • Graphene has attracted tremendous attention for the last a few years due to it fascinating electrical, mechanical, and chemical properties. Up to now, several methods have been developed exclusively to prepare graphene, which include micromechanical cleavage, polycrystalline Ni employing chemical vapor deposition technique, solvent thermal reaction, thermal desorption of Si from SiC substrates, chemical routes via graphite intercalation compounds or graphite oxide. In particular, polycrystalline Ni foil and conventional chemical vapor deposition system have been widely used for synthesis of large-area graphene. [1-3] In this study, synthesis of mono-layer graphene on a Ni foil, the mixing ratio of hydrocarbon ($CH_4$) gas to hydrogen gas, microwave power, and growth time were systemically optimized. It is possible to synthesize a graphene at relatively lower temperature ($500^{\circ}C$) than those (${\sim}1000^{\circ}C$) of previous results. Also, we could control the number of graphene according to the growth conditions. The structural features such as surface morphology, crystallinity and number of layer were investigated by scanning electron microscopy (SEM) and atomic force microscopy (AFM), transmission electron microscopy (TEM) and resonant Raman spectroscopy with 514 nm excitation wavelength. We believe that our approach for the synthesis of mono-layer graphene may be potentially useful for the development of many electronic devices.

  • PDF

Classical swine fever disease in Cheolwon

  • Park Yang-Soon;Shin Myung-Kyun;Chong Dong-Soo;Cheong Ki-Soo;Park Young-Nam;Choi Jee-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.4
    • /
    • pp.345-354
    • /
    • 2004
  • Two cases of classical swine fever (CSF) disease have broken out in Cheolwon (7 April, 2002). The suspected pig herds were huddled together because of high fever (over $40^{\circ}C$) and showed remarkable decrease of the leukocytes. The staggering gait related to posterior weakness, constipation and lethargy, hyperemia, hemorrhagic lesions (on the skin, muzzle, ears, limbs, tail and inner part of legs) and conjunctivitis with dirty streaks below the eyes were observed. The inflammation in the lung, infarction in the spleen, swelling and hemorrhage in lymph nodes, kidney, intestine, heart and cheese like purulent inflammation of the tonsil were observed. The ulcers of the colon were also detected. Several clinical and laboratory techniques including blood test, histo-pathological examinations, indirect fluorescent antibody (IFA) test and RT-PCR test were applied to diagnose the disease. Inoculation test on PK-15 cell was also performed. The necrosis of the lymphatic cells and infiltration of the vessel circumferential cells in the brain and lymph organs were commonly viewed. The proliferation of the glia cell (gliosis) in the lymph was particular. Cytopathogenic effect (CPE) and specific fluorescent-bright-green areas (with IFA) appeared in PK-15 cells inoculated with suspected blood plasma. The IFA test on the epithelial and mucous membrane cells of tonsil was positive. RT-PCR technique required more working hours and labor than other techniques in this examination but it was useful because of the sensitivity to the CSF viral gene.

Shubnikov-de Haas Oscillations in an Individual Single-Crystalline Semimetal Bismuth Nanowire (단결정 반금속 비스무스 단일 나노선의 Shubnikov-de Haas 진동)

  • Kim, Jeong-Min;Ham, Jin-Hee;Shim, Woo-Young;Lee, Kyoung-Il;Jeon, Kye-Jin;Jeung, Won-Young;Lee, Woo Young
    • Korean Journal of Materials Research
    • /
    • v.18 no.2
    • /
    • pp.103-106
    • /
    • 2008
  • The magneto-transport properties of an individual single crystalline Bi nanowire grown by a spontaneous growth method are reported. A four-terminal device based on an individual 400-nm-diameter nanowire was successfully fabricated using a plasma etching technique that removed an oxide layer that had formed on the surface of the nanowire. Large transverse ordinary magnetoresistance (1401%) and negative longitudinal ordinary magnetoresistance (-38%) were measured at 2 K. It was observed that the period of Shubnikov-de Haas oscillations in transverse geometry was $0.074^{T-1}$, $0.16^{T-1}$ and $0.77^{T-1}$, which is in good agreement with those of bulk Bi. However, it was found that the period of SdH oscillation in longitudinal geometry is $0.24^{T-1}$, which is larger than the value of $0.16^{T-1}$ reported for bulk Bi. The deviation is attributable to the spatial confinement arising from scattering at the nanowire surface boundary.

General Pharmacology of Erythropoietin Produced by a New Recombinant DNA Technique (새로운 유전자 재조합 기술에 의하여 생산된 Erythropoietin의 일반약리작용)

  • 김영훈;정성목;임동문;조효진;정재경;김달현;박관하;이동억;김현수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.336-342
    • /
    • 1994
  • The general pharmacological properties of EPO were investigated in various animals administering intravenously and in vitro system. The results were as follows. 1. Central nervous system: EPO at doses of 70, 700, 7000 U/kg showed no effect In mice on general behavior, on strychnine- and pentetrazol-induced convulsion and on acetic acid-induced writhing syndrome. The hexobarbital-induced sleeping time in mice was slightly reduced by EPO at a dose of 7000 U/kg but did not change at doses of 70, 700 U/kg. The body temperature in rats was slightly decreased by EPO at doses of 700, 7,000 U/kg but the change was in normal physiological range. 2. Respiratory and cardiovascular system: EPO showed no effect on respiratory rate, blood pressure, heart rate, femoral blood flow, and electrocardiogram in anesthetized dogs at doses of 70, 700, 7000 U/kg. 3. Smooth muscle: EPO at concentrations of 70, 700 U/ml had no effect on the contractile response of isolated guinea pig ileum to histamine and acetylcholine. 4. Water and electrolytes excretion: EPO at dose above 700 U/kg increased urine volume in rats but did not affect the concentrations of $Na^{+},\;K^{+},\;Cl^{-}$ in urine. 5. Gastrointestinal system: EPO(70, 700, 7000 U/kg) had no effect on the intestinal charcoal meal propulsion 6. Blood coagulation system: The administration of EPO(70, 700, 7000 U/kg) had no effect on the plasma prothrombin time(PT) and activated partial thromboplastin time(APTT) in mice. Platelet aggregation induced by ADP and collagen was not influenced by EPO(70 U/ml, 700 U/ml). The overall results obtained indicated that EPO exerts almost no serious pharmacological effect even at a 100-fold clinical dose(7000 U/kg).

  • PDF

Hard TiN Coating by Magnetron-ICP P $I^3$D

  • Nikiforov, S.A.;Kim, G.H.;Rim, G.H.;Urm, K.W.;Lee, S.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.414-420
    • /
    • 2001
  • A 30-kV plasma immersion ion implantation setup (P $I^3$) has been equipped with a self-developed 6'-magnetron to perform hard coatings with enhanced adhesion by P $I^3$D(P $I^3$ assisted deposition) process. Using ICP source with immersed Ti antenna and reactive magnetron sputtering of Ti target in $N_2$/Ar ambient gas mixture, the TiN films were prepared on Si substrates at different pulse bias and ion-to-atom arrival ratio ( $J_{i}$ $J_{Me}$ ). Prior to TiN film formation the nitrogen implantation was performed followed by deposition of Ti buffer layer under A $r^{+}$ irradiation. Films grown at $J_{i}$ $J_{Me}$ =0.003 and $V_{pulse}$=-20kV showed columnar grain morphology and (200) preferred orientation while those prepared at $J_{i}$ $J_{Me}$ =0.08 and $V_{pulse}$=-5 kV had dense and eqiaxed structure with (111) and (220) main peaks. X-ray diffraction patterns revealed some amount of $Ti_{x}$ $N_{y}$ in the films. The maximum microhardness of $H_{v}$ =35 GN/ $M^2$ was at the pulse bias of -5 kV. The P $I^3$D technique was applied to enhance wear properties of commercial tools of HSS (SKH51) and WC-Co alloy (P30). The specimens were 25-kV PII nitrogen implanted to the dose 4.10$^{17}$ c $m^{-2}$ and then coated with 4-$\mu\textrm{m}$ TiN film on $Ti_{x}$ $N_{y}$ buffer layer. Wear resistance was compared by measuring weight loss under sliding test (6-mm $Al_2$ $O_3$ counter ball, 500-gf applied load). After 30000 cycles at 500 rpm the untreated P30 specimen lost 3.10$^{-4}$ g, and HSS specimens lost 9.10$^{-4}$ g after 40000 cycles while quite zero losses were demonstrated by TiN coated specimens.s.

  • PDF

Studying Thermochemical Conversion of Sm2O3 to SmCl3 using AlCl3 in LiCl-KCl Eutectic Melt

  • Samanta, Nibedita;Chandra, Manish;Maji, S.;Venkatesh, P.;Annapoorani, S.;Jain, Ashish
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.279-291
    • /
    • 2022
  • In this report the thermochemical conversion of Sm2O3 to SmCl3 using AlCl3 in LiCl-KCl melt at 773 K is discussed. The final product was a mixture of SmCl3, Al2O3, unreacted Sm2O3 and AlCl3 in the chloride melt. The electrochemical attributes of the mixture was analyzed with cyclic voltammetry (CV) and square wave voltammetry (SWV). The crystallographic phases of the mixture were studied with X-ray diffraction (XRD) technique. The major chemical conversion was optimized by varying the effective parameters, such as concentrations of AlCl3, duration of reaction and the amount of LiCl-KCl salt. The extent of conversion and qualitative assessment of efficiency of the present protocol were evaluated with fluorescence spectroscopy, UV-Vis spectrophotometry and inductively coupled plasma atomic emission spectroscopy (ICP-AES) studies of the mixture. Thus, a critical assessment of the thermochemical conversion efficiency was accomplished by analysing the amount of SmCl3 in LiCl-KCl melt. In the process, a conversion efficiency of 95% was achieved by doubling the stoichiometric requirement of AlCl3 in 50 g of LiCl-KCl salt. The conversion reaction was found to be very fast as the reaction reached equilibrium in 15 min.

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.

Elemental alteration of the surface of dental casting alloys induced by electro discharge machining (치과용 주조 합금의 방전가공에 따른 표면 성분 변화)

  • Jang, Yong-Chul;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

Heavy Metal Contents in Upland Soils and Crops of Korea (우리나라 밭 토양 및 작물의 중금속함량)

  • Jung, Goo-Bok;Kim, Ho-Chung;Jung, Ki-Yeol;Jung, Beung-Kan;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.3
    • /
    • pp.225-232
    • /
    • 1998
  • In order to monitor the degree of heavy metal distribution in upland cultivations in Korea, both the cultivated soils and crops were collected from the 854 and 140 sites, respectively. The contents of cadmium (Cd), copper(Cu), lead(Pb), and zinc(Zn) in each sample were measured by Inductively Coupled Plasma(ICP) technique after 1N-HCl extraction. The content of Arsenic(As) was also measured with the same technique after 1N-HCl extraction. The average contents of heavy metal in surface soils(0~15 cm depth) were $0.135mg\;kg^{-1}$ for Cd, $2.77mg\;kg^{-1}$ for Cu, $3.47mg\;kg^{-1}$ for Pb, $10.7mg\;kg^{-1}$ for Zn, and $0.57mg\;kg^{-1}$ for As. Heavy metal contents of soil were similar to those values measured for upland soils in 1989, lower than soils under plastic film house in 1996. However, these contents were lower than "Countermeasure values for soil contamination"(Cd: 4, Cu: 125, Pb: 300, and As: $15mg\;kg^{-1}$ in soil) describled in Soil Environmental Conservation Act in Korea(1996). The contents of heavy metal in fresh vegetable, and root and tuber crops ranged $0.005{\sim}0.019mg\;kg^{-1}$ for Cd, $0.20{\sim}1.03mg\;kg^{-1}$ for Cu, $0.042{\sim}0.104mg\;kg^{-1}$ for Pb, and $2.0{\sim}4.0mg\;kg^{-1}$ for Zn, respectively.

  • PDF

Knockdown of Archvillin by siRNA Inhibits Myofibril Assembly in Cultured Skeletal Myoblast

  • Lee, Yeong-Mi;Kim, Hyun-Suk;Choi, Jun-Hyuk;Choi, Jae-Kyoung;Joo, Young-Mi;Ahn, Seung-Ju;Min, Byung-In;Kim, Chong-Rak
    • Biomedical Science Letters
    • /
    • v.13 no.4
    • /
    • pp.251-261
    • /
    • 2007
  • A myofiber of skeletal muscle is composed of myofibrils, sarcolemma (plasma membrane), and constameres, which anchor the myofibrils to the sarcolemma. Achvillin is a recently identified F-actin binding muscle protein, co-isolates with dystrophin and caveolin-3 in low-density sarcolemma of striated muscle, and colocalizes with dystrophin at costameres, the specialized adhesion sites in muscle. Archvillin also binds to nebulin and localizes at myofibrillar Z-discs, the lateral boundaries of the sarcomere in muscle. However other roles of archvillin on the dynamics of myofibrillogenesis remain to be defined. The goal of this study is, by using siRNA-mediated gene silencing technique, to investigate the effect of archvillin on the dynamics of myofibrillogenesis in cell culture of a mouse skeletal myogenic cell line (C2C12), where presumptive myoblasts withdraw from the cell cycle, fuse, undergo de novo myofibrillogenesis, and differentiate into mature myotubes. The roles of archvillin in the assembly and maintenance of myofibril and during the progression of myofibrillogenesis induced in skeletal myoblast following gene silencing in the cell culture were investigated. Fluorescence microscopy demonstrated that the distribution of archvillin was changed along the course of myofibril assembly with nebulin, vinculin and F-actin and then located at Z-lines with nebulin. Fluorescence microscopy demonstrated that knockdown of mouse archvillin expression led to an impaired assembly of new myofibrillar clusters and delayed fusion and myofibrillogenesis although the mouse archvillin siRNA did not affect those expressions of archvillin binding proteins, such as nebulin and F-actin. This result is corresponded with that of RT-PCR and western blots. When the perturbed archvillin was rescued by co-transfection with GFP or Red tagged human archvillin construct, the inhibited cell fusion and myotube formation was recovered. By using siRNA technique, archvillin was found to be involved in early stage of myofibrillogenesis. Therefore, the current data suggest the idea that archvillin plays critical roles on cell fusion and dynamic myofibril assembly.

  • PDF