• Title/Summary/Keyword: plasma in liquid

Search Result 614, Processing Time 0.031 seconds

Preparation and characterization of high transmittance and low resistance index matched transparent conducting oxide coated glass for liquid crystal on silicon panel

  • Jang, Chang-Young;Paik, Woo-Sung;Choi, Bum-Ho;Kim, Young-Back;Lee, Jong-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1415-1417
    • /
    • 2009
  • High transmittance and low resistance index matched transparent conducting oxide (IMTCO) coated glass was prepared and characterized. IMTCO was deposited by RF magnetron sputtering with the thickness of 15nm and 90nm thick anti-reflection layer was evaporated. To modify surface to hydrophilic, in-situ plasma treatment was also performed. IMTCO coated glass exhibited 96.6% of transmittance in the wavelength range of 400~700nm which is relatively high value compared to commercially available IMTCO glass. The sheet resistance uniformity was measured to be 1.53%.

  • PDF

Fabrication of refractive PMMA microlens array using transparent acrylic resin (투명 아크릴 레진을 이용한 초소형 PMMA 렌즈 배열의 제작)

  • Ahn, Si-Hong;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3316-3318
    • /
    • 1999
  • PMMA(poly-methyl methacrylate) microlens array is fabricated using transparent acrylic resin. PMMA is commonly used material for plastic lens due to its excellent visibility larger than 90% and other optical characteristics so much close to those of glass. Orthodontic resin (DENTSPLY International Inc.), commonly used in dentistry, is an transparent acrylic resin kit including MMA liquid and polymerization powder. Their mixture results in PMMA through polymerization. Using the resin PMMA layer is formed on the substrate through spin-coating. Designed pattern of lens structure is transferred to PMMA layer by RIE (Reactive Ion Etching) with oxygen plasma. Final lens shape is formed by thermal treatment that causes PMMA to reflow, The thickness of PMMA spun on the substrate is $17{\mu}m$ that is also final sag of microlens, Designed diameters of the microlenses are $200{\mu}m$, $300{\mu}m$,and $500{\mu}m$, respectively.

  • PDF

Properties of ITO Transparent Conducting Film by DC Magnetron Sputtering Method (DC 마그네트론 스퍼터법에 의한 ITO 투명전도막 특성)

  • Park, Kang-Il;Kim, Byung-Sub;Lim, Dong-Gun;Park, Gi-Yub;Kwak, Dong-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.95-98
    • /
    • 2003
  • Tin doped indium oxide(ITO) films, which is widely used as a transparent conductor in optoelectronic devices such as solar cell, liquid crystal display, plasma display panel, thermal heater, and other sensors, were prepared by using the capacitively coupled DC magnetron sputtering method. The influence of the substrate temperature, working gas pressure and deposition time on the electrical, optical and morphological properties were investigated experimentally. ITO films with the optimum growth conditions showed resistivity of $2.36{\times}10^{-4}(\Omega}-cm$ and transmittance of 86.28% for a film 680nm thick in the wavelength range of the visible spectrum.

  • PDF

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.

A Freeze-fracture Study on the Odontoblast of Dental Pulp in the Rat Incisor (흰쥐 절치치수의 Odontoblast에 관한 Freeze-Fracture 연구)

  • Kim, Myung-Kook
    • Applied Microscopy
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study was to investigate the morphology and intercellular junctions of the odontoblast of dental pulp in the rat incisor by means of the freeze fracture electron microscopy. Twenty male Sprague-Dawley rats weighing $150{\sim}200g$ were used. After being anesthetized by an intraperitoneal injection of 0.5 ml sodium pentobarbital per kg in body weight(60 mg/ml) the animals were perfused with 2.5% glutaraldehyde-2% paraformaldehyde fixative in 0.1 M cacodylate buffer, pH 7.2 through the ascending aorta for one hour. The incisors were carefully extracted from the jaws and demineralized by suspending them in 0.1 M EDTA in 3% glutaraldehyde (pH 7.2) for two weeks. After demineralization, the specimens were obtained from the portion divided into five equal parts. For freeze-fracture replication, demineralized tissues were infiltrated for several hours with 10%, 25% glycerol in 0.1M cacodylate buffer as a cryoprotectant and then frozen in liquid Freon 22 and stored in liquid nitrogen. Fracturing and replication were done in Balzers BAF 400D high-vacuum freeze-fracture apparatus at $-120^{\circ}C$ under routine $5X10^{-7}$ Torr vacuum. The tissue was immediately replicated with platinum unidirectionally at $45^{\circ}$ angle and reinforced with carbon at $90^{\circ}$ angle unidirectionally or by using a rotary stage. The replication process was monitored by a quartz-crystal device. The replicas were immersed in 100% methanol overnight. The tissue was then digested from the replica by clorox (laundry bleach), placed into 5% EDTA, and washed repeatedly with distilled water. The replicas were picked up on 0.3% formvar-coated 75 mesh grids and examined in the JEOL 100B electron microscope. The results were as follows; 1. Both in thin sections and freeze-fracture replicas, three types of intercellular junctions were recognizable in the plasma membrane of odontoblast: gap junction, tight junction and desmosome-like junction. 2. The nuclear pores were evenly distributed over the nuclear envelope. The pore complex formed a ring about 70 nm in diameter. 3. Gap junctions were found between odontoblasts as well as odontoblasts and neighbouring pulp cells (fibroblast, subodontoblastic cell process, nerve-like fibre). Gap junctions, which were round, ellipsoid and pear-shaped and 600 nm in diameter, were observed in the odontoblast. 4. Numerous round and ellipsoid gap junctions could be frequently seen on the plasma membranes in cell body and apical part of the odontoblasts. On the P face, the junctions were recognized as a cluster of closely packed particles, measuring about 9 nm in diameter, and on the E face, the junctions were recognized as a shallow grooves.

  • PDF

Separation and identification of selenoproteins in selenium-enriched yeast (셀레늄이 강화된 이스트에서 셀레늄 단백질의 분리 및 확인)

  • Kim, Kyong-Mi;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.357-363
    • /
    • 2013
  • Selenium-containing proteins were separated from selenium-enriched yeast (SEY) using Trizol$^{(R)}$ reagent followed by anion exchange (AE) chromatography. This method is simpler and less time consuming than electrophoresis. Five selenium containing proteins were identified by on-line AE HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry). Each protein was enzymatically hydrolyzed to seleno-amino acids and separated with RP (reverse phase) HPLC for the identification of selenoproteins.

Determination of Toxic Elements in Blood by Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang-Jun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.99-99
    • /
    • 1993
  • 혈액 및 생체시료 중 필수원소 혹은 독극성 원소의 극미량상분 정밀측정과 동위원소비율측정에 널리 사용되는 유도결합플라즈마 질량분석기(ICP-MS)의 기본원리를 소개하고 ICP-SM를 이용한 혈액중 낮은 ppb수준의 Cd, Hg 그리고 Pb의 정밀분석법을 소개한다. 혈액은 많은 양의 유기물을 포함하고 있으므로 digestion bomb에 질산과 과산화수소를 넣어 microwave oven에서 고온고압 상태로 분해시켜 많은 용액을 얻어 이 용액을 플라즈마에 주입시켜 분석한다. 그리고 수온은 tin(II) chloride 용액을 환원제로하여 생성시킨 수은원소증기를 membrane liquid-gas separator를 이용하여 뽑아내어 플라즈마에 주입시켜 낮은 ppt 수준의 검출한계를 얻는다. 또한 높은 정밀도와 정확도와 극미량 원소 측정에 사용되는 동위원소 회석법율 소개하고 실제 혈액분석에의 응용방법을 제시한다.

  • PDF

Two-Dimensional Simulation of Hg Flat Fluorescent Lamps for an LCD Backlight unit (액정디스플레이 후판광원용 평판형 수은 형광램프의 2차원 시뮬레이션 연구)

  • Yoon, Hyun-Jin;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1275-1281
    • /
    • 2007
  • The discharge phenomena in a flat fluorescent lamp for the backlight unit of liquid crystal displays are simulated by sung a two-dimensional fluid model. The numerical methods for the calculation of plasma dynamics and the radiation transport are introduced for the discharge simulation and for the transmission of the vacuum ultraviolet lights. The simulation results are presented to compare the luminance and the luminance efficacy with the variation of gas pressure, gas mixture ratio, driving voltage, and frequency.

Liquid precursor delivery system for ultra thin film preparation (극미세 절연체 박막 증착을 위한 액상전구체 공급장치 제작)

  • Ahn, Tae-Jun;Choi, Bum Ho;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.175-176
    • /
    • 2018
  • We have developed liquis precursotr delivery system (LDS) for ultra thin film preparation in semiconductor devices. The LDS concists of 3 major parts : aerosol generator, vaporizer and vapor storage. By uaing LDS which was attached to plasma enhanced chemical vapor deposition system, thin Al2O3 layer was prepared at extremely low temperature and characterized.

  • PDF