• 제목/요약/키워드: plasma discharge

검색결과 1,417건 처리시간 0.029초

Surface treatment of sol-gel bioglass using dielectric barrier discharge plasma to enhance growth of hydroxyapatite

  • Soliman, Islam El-Sayed;Metawa, Asem El-Sayed;Aboelnasr, Mohamed Abdel Hameed;Eraba, Khairy Tohamy
    • Korean Journal of Chemical Engineering
    • /
    • 제35권12호
    • /
    • pp.2452-2463
    • /
    • 2018
  • Surface treatment of sol-gel bioglass is required to increase its biomedical applications. In this study, a dielectric barrier discharge (DBD) plasma treatment in atmospheric pressure was performed on the surface of [$SiO_2-CaO-P_2O_5-B_2O_3$] sol-gel derived glass. The obtained bioglass was treated by plasma using discharge current 12 mA with an exposure period for 30 min. The type of discharge can be characterized by measuring the discharge current and applied potential waveform and the power dissipation. Apatite formation on the surface of the DBD-treated and untreated samples after soaking in simulated body fluid (SBF) at $37^{\circ}C$ is characterized by Fourier transform infrared spectroscopy (FTIR), X-Ray diffraction (XRD), inductively coupled plasma (ICP-OES) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS). We observed a marked increase in the amount of apatite deposited on the surface of the treated plasma samples than those of the untreated ones, indicating that DBD plasma treatment is an efficient method and capable of modifying the surface of glass beside effectively transforming it into highly bioactive materials.

플라즈마 디스플레이 패널의 방선 AND gate에 간한 연구 (A Study on the Discharge AND Gate of Plasma Display Panels)

  • 손현성;채승엽;염정덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.39-46
    • /
    • 2001
  • The plasma display panel with the electrode structure of new discharge AND gate was developed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the imput discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore, it is possible to apply to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning electrical discharge does not influence the picture quality.

  • PDF

이산화탄소의 무성방전특성에 미치는 방전관의 구조 (The Effect of Discharge Chamber Structure on the Barrier Discharge of $CO_2$)

  • 박명하;곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.207-211
    • /
    • 2000
  • Deep Interests have been paid on the application of non-thermal plasma technique to solve the environmental pollution problems. $CO_2$ is one of the severe pollutants which cause the acid rain and global warming. In this study, in order to improve the conversion efficiency of $CO_2$, the streamer corona discharge plasma and barrier discharge plasma reactors were made, and the conversion characteristics of $CO_2$ by the corona discharge plasma and some discharge characteristics of these discharge chambers are studied experimentally.

  • PDF

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권3호
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

히터 일체형 하이브리드 단판형 플라즈마 방전소자 (One-Plate Type Hybrid Plasma Discharge Device with Heating Element)

  • 최우진;최은혜;성형석;권진구;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

Electron Temperature, Plasma Density and Luminous Efficiency in accordance with Discharge Time in coplanar AC PDPs

  • Jeong, S.H.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1203-1206
    • /
    • 2005
  • Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP's) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time ($0{\sim}72$ Hours). As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature. So the plasma density was decreased from $1.8{\times}10^{12}cm^{-3}$ to $8{\times}10^{11}cm^{-3}$ at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

  • PDF

Characteristics of Nonthermal Plasma Source in Various Liquids

  • Lim, Seung-Ju;Min, Boo-Ki;Taylor, Nathan;Kim, Tae-Gyu;Kim, Hyeong-Seok;Yang, Seon-Pil;Jung, Jin-Yong;Han, Jin-Hyun;Lee, Jong-Yong;Kang, Seung-Oun;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.259.1-259.1
    • /
    • 2014
  • Recently non-thermal plasma has been frequently applied to various research fields. The liquid plasma have received much attention lately because of interests in surgical and nanomaterial synthesis applications. Especially, intensive researches have been carried out for non-thermal plasma in liquid by using various electrode configurations and power supplies. We have developed a bioplasma source which could be used in a liquid, in which outer insulator has been covered onto the outer electrode. Also we have also put an insulator between the inner and outer electrode. Based on the surface discharge mode, the nonthermal bioplasma has been generated inside a liquid by using an alternating current voltage generator with peak voltage of 12 kV under driving frequency of 22 KHz. Here the discharge voltage and current have been measured for electrical characteristics. Especially, We have measured discharge and optical characteristics under various liquids of deionized (DI) water, tap water, and saline by using monochromator. We have also observed nitric oxide (NO), hydrogen peroxide (H2O2), and hydroxyl (OH) radical species by optical emission spectroscopy during the operation of bioplasma discharge inside various kinds of DI water, tap water, and saline. Here the temperature has been kept to be $40^{\circ}C$ or less when discharge in liquid has been operated in this experiment. Also we have measured plasma temperature by high speed camera image and density by using either H-alpha or H-beta Stark broadening method.

  • PDF

AC PDP의 온도에 따른 방전 특성 연구 (A Study on the Temperature-Dependent Discharge Characteristics in Alternating Current Plasma Display Panel)

  • 이석현;김지용
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.577-582
    • /
    • 2007
  • The plasma display panel is an image expression display using gas discharge plasma. However, gas discharge characteristics vary with temperature as gas discharge is sensitive to temperature. The discharge time lag extends a lot in low temperature and it is known as the cause which hinders high speed addressing which is essential for the size enlargement of the panel. Accordingly this research aims at identifying the temperature-dependent discharge characteristic. The lower temperature becomes, the longer addressing discharge time lag becomes. Particularly the statistical time lag extends much in low temperature. The increasing of electric field shortens discharge time lag in low temperature. Also, when priming particles are sufficiently supplied, stable discharge can be performed regardless of the influence of temperature.

3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode)

  • 문재덕;정재승
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

Advanced Microwave Plasma Technology for Liquid Treatment

  • Toyoda, Hirotaka;Takahashi, T.;Takada, N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.121.1-121.1
    • /
    • 2014
  • Recently, much attention has been given to plasma production under liquid and its applications [1]. However, most of plasma production techniques reported so far utilize high voltage dc, ac, rf or microwave power [2], where damage to discharge electrodes and small discharge volume are remained issues. As an alternative of plasma production method under liquid, we have proposed pulsed microwave excited plasma using slot antenna, where damage to the slot electrode can be minimized and plasma volume can be increased. We have also reported improvement of treatment efficiency with use of reduced-pressure condition during the discharge [3]. To realize low pressure conditions in liquid, various alternative technique can be considered. One possible technique is simultaneous injection of microwave power and ultrasonic wave. Ultrasonic wave induces pressure fluctuation with the wave propagation and is so far used for cavitation production in the water. We propose utilization of reduced pressure induced by ultrasonic cavitation for improvement of the plasma production. Correlation between the plasma production and the ultrasonic power will be discussed.

  • PDF