• Title/Summary/Keyword: plasma $D_3$

Search Result 1,087, Processing Time 0.03 seconds

Development and Validation of an LC-MS/MS Method for Determination of Damaurone D in Rat Plasma and its Application to Pharmacokinetic Study in Rats

  • Lee, Wonpyo;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.38-42
    • /
    • 2019
  • Damaurone D belongs to the genus Rosa and is a traditional medicinal product used for the treatment of depression, inflammation, and infectious diseases. The purpose of this study was to develop a simple liquid chromatography-tandem mass spectrometry method for the detection of damaurone D in rat plasma and to demonstrate its application in pharmacokinetic studies. Damaurone D and berberine (internal standard) were extracted with acetonitrile using a protein precipitation method. Mass transition was monitored in multiple reaction monitoring mode at m/z $323.2{\rightarrow}267.0$ for damaurone D and m/z $336.1{\rightarrow}320.0$ for berberine in positive ion mode. Analytical validation was conducted by evaluating the specificity, linearity, accuracy, precision, matrix effect, extraction recovery, and stability. The calibration curves were linear over 2-1000 ng/mL. The intra- and inter-day precision and accuracy of quality control samples were 4.79-13.33% and 86.23-102.75%, respectively. The matrix effect and extraction recovery were 96.11-98.47% and 96.11-102.25%, respectively. In the pharmacokinetic study after intravenous administration of damaurone D at a dose of 3 mg/kg in rats, the area under the curve and clearance of damaurone D in rat plasma were $16750.26{\pm}2676.10min{\cdot}ng/mL$ and $182.44{\pm}31.36mL/min/kg$, respectively.

Investigation of the TiCrN Coating Deposited by Inductively Coupled Plasma Assisted DC Magnetron Sputtering. (Inductively Coupled Plasma Assisted D.C. Magnetron Sputtering법으로 제작된 TiCrN 코팅층의 특성 분석)

  • Cha, B.C.;Kim, J.H.;Lee, B.S.;Kim, S.K.;Kim, D.W.;Kim, D.;You, Y.Z.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.5
    • /
    • pp.267-274
    • /
    • 2009
  • Titanium Chromium Nitrided (TiCrN) coatings were deposited on stainless steel 316 L and Si (100) wafer by inductively coupled plasma assisted D.C. magnetron sputtering at the various sputtering power on Cr target and $N_2/Ar$ gas ratio. Increasing the sputtering power of Cr target, XRD patterns were changed from TiCrN to nitride $Cr_2Ti$. The maximum hardness was $Hk_{3g}$ 3900 at $0.3\;N_2/Ar$ gas ratio. The thickness of the TiCrN films increased as the Cr target power increased, and it showed over $Hk_{5g}3100$ hardness at 100 W, 150 W. TiCrN films were deposited by the ICP assisted DC magnetron sputtering shown good wear resistance as the $N_2/Ar$ gas ratio was 0.1, 0.3.

Fabrication and Characterization of 7.5 wt% Y2O3-ZrO2 Thermal Barrier Coatings Deposited by Suspension Plasma Spray (서스펜션 플라즈마 용사법을 이용한 7.5 wt% Y2O3-ZrO2 열차폐코팅 제조 및 평가)

  • Lee, Won-Jun;Oh, Yoon-Suk;Lee, Sung-Min;Kim, Hyung-Tae;Lim, Dae-Soon;Kim, Seongwon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.6
    • /
    • pp.598-604
    • /
    • 2014
  • Considerable research efforts have been explored attempting to enhance the thermal durability of thermal barrier coatings (TBCs) at the high operating temperatures of gas turbines. In this study, the suspension plasma spray (SPS) process was applied to produce TBCs with a segmented structure by using an yttria-stabilized zirconia (YSZ) suspension. Four different experiment sets were carried out by controlling the ratio between surface roughness of the bond coat and feed stock size ($R_a/D_{50}$) in order to examine the effect of $R_a/D_{50}$ ratio on the microstructure of SPS-prepared coatings. When the $R_a/D_{50}$ had a high value of 11.8, a deposited thick coating turned out to have a cone-type columnar microstructure. In contrast, at the low $R_a/D_{50}$ values of 2.9 and 0.18, a deposited thick coating appeared to have a dense, vertically-cracked microstructure. However, with the very low $R_a/D_{50}$ value of 0.05 the coating was delaminated.

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF

Plasma nitriding on chromium electrodeposit

  • Wang Liang;K.S. Nam;Kim, D.;Kim, M.;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.29-30
    • /
    • 2001
  • This paper presents some results of plasma nitriding on hard chromium deposit. The substrates were C45 steel and $30~50{\;}\mu\textrm{m}$ of chromium deposit by electroplating was formed. Plasma nitriding was carried out in a plasma nitriding system with $95NH_3{\;}+{\;}SCH_4$ atmosphere at the pressure about 600 Pa and different temperature from $450^{\circ}C{\;}to{\;}720^{\circ}C$ for various time. Optical microscopy and X-ray diffraction were used to evaluate the characteristics of surface nitride layer formed by nitrogen diffusion from plasma atmosphere inward iCr coating and interface carbide layer formed by carbon diffusion from substrate outward Cr coating. The microhardness was measured using microhareness tester at the load of 100 gf. Corrosion resistance was evaluated using the potentiodynamic measurement in 3.5% NaG solution. A saturated calomel electrode (SiCE) was used as the reference electrode. Fig.1 shows the typical microstructures of top surface and cross-section for nitrided and unnitrided samples. Aaer plasma nitriding a sandwich structure was formed consisting of surface nitride layer, center chromium layer and interface carbide layer. The thickness of nitride and carbide layers was increased with the increase of processing temperature and time. Hardness reached about 1000Hv after nitriding while 900Hv for unnitrided hard chromium deposit. X-ray diffraction indicated that surface nitrided layer was a mixture of $Cr_2N$ and CrN at low temperature and erN at high temperature (Fig.2). Anodic polarization curves showed that plasma nitriding can greatly improve the corrosion resistance of chromium e1ectrodeposit. After plasma nitriding, the corrosion potential moved to noble direction and passive current density was lower by 1 to 4 orders of magnitude compared with chromium deposit(Fig.3).

  • PDF

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF

Plasma Surface Modification of Graphene and Combination with Bacteria Cellulose (Graphene의 플라즈마 표면 개질과 박테리아 셀룰로오스와의 결합성 검토)

  • Yim, Eun-Chae;Kim, Seong-Jun;Oh, Il-Kwon;Kee, Chang-Doo
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.388-393
    • /
    • 2013
  • The study was focused to evaluate the possibility for combination membrane of bacterial cellulose (BC) and graphene with high electrical properties. BC with natural polymer matrix was known to have strong physical strength. For the combination of graphene with BC, the surface of graphene was modified with oxygen plasma by changing strength and time of radio waves in room temperature. Water contact angle of modified graphene grew smaller from $130^{\circ}$ to $12^{\circ}$. XPS analysis showed that oxygen content after treatment increased from 2.99 to 10.98%. Damage degree of graphene was examined from $I_D/I_G$ ratio of Raman analysis. $I_D/I_G$ ratio of non-treated graphene (NTG) was 0.11, and 0.36 to 0.43 in plasma treated graphene (PTG), increasing structural defects of PTG. XRD analysis of PTG membrane with BC was $2{\theta}$ same to BC only, indicating chemically combined membrane. In FT-IR analysis, 1,000 to 1,300 $cm^{-1}$ (C=O) peak indicating oxygen radicals in PTG membrane had formed was larger than NTG membrane. The results suggest that BC as an alternation of plastic material for graphene combination has a possibility in some degree on the part like transparent conductive films.

Preparation and Investigation of Characteristics of Diamond-like Carbon Thin Films by Acetylene Plasma (아세틸렌 플라스마를 이용한 다이아몬드성 탄소 박막의 제작 및 특성)

  • Youk, Do Jin;Kang, Sung Soo;Lee, Won Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • The a-C:H films have been grown on the glass substrate by PECVD mathod, where plasma was generated with a 60Hz line power source. The carbonization is checked from peak intensities of D($sp^3$) and G($sp^2$) peaks in Raman spectra. The hydronization and C-H bonding status in films can also be determined from FTIR results. Both the bonding strength of C-H and the ratio of $sp^3$ to $sp^2$ in bonding are found to be slightly dependent of partial pressure of $C_2H_2$. Judging from above results, we can conclude that the best value for partial pressure of $C_2H_2$ in growing process of thick films is about 15%.

  • PDF

Identification and Characterization of Phytochrome-Regulated Phospholipase D in Oat Cells (Avena sativa L.)

  • Park, Cheon;Park, Moon-Hwan;Chae, Quae
    • BMB Reports
    • /
    • v.29 no.6
    • /
    • pp.535-539
    • /
    • 1996
  • The activation of phospholipase D (PLD) catalyzes hydrolysis of phosphatidylcholine (PC) to phosphatidic acid (PA) and choline in plants as well as animals. To determine the presence of PLD in oat cells, we prepared inside-out plasma membrane and cytosolic fractions from oat tissues. PLD activities in both cytosol and plasma membrane were detected by ion chromatography method. The activity of PLD in plasma membrane was dependent upon $Ca^{2+}$ concentration and was heat stable. To investigate whether G-protein couples to PLD, the effects of $GTP{\gamma}S$ and $GDP{\beta}S$ on the PLD activity were measured. PLD activity was dramatically increased 300~400% in the presence of 50 ${\mu}M$ $GTP{\gamma}S$ but not in the presence of 50 ${\mu}M$ $GDP{\beta}S$. These results indicate that G-protein may be involved in regulation of PLD activity. To identify whether PLD is regulated by red light receptor, phytochrome, we irradiated red, far-red, or red/far-red/red light on oat protoplasts. PLD activity has increased 5-fold and 3-fold by treatment with red light and red/far-red/red light, respectively. In contrast, irradiation with far-red light had little or no effect on PLD activity. These results suggest that phytochrome regulates PLD activity through activation of G-protein in oat cells.

  • PDF

Surface Modification by Atmospheric Pressure DBDs Plasma: Application to Electroless Ni Plating on ABS Plates

  • Song, Hoshik;Choi, Jin Moon;Kim, Tae Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.133-138
    • /
    • 2013
  • Acrylonitrile-butadiene-styrene (ABS) plastic is a polymer material extensively used in electrical and electronic applications. Nickel (Ni) thin film was deposited on ABS by electroless plating, after its surface was treated and modified with atmospheric plasma generated by means of dielectric barrier discharges (DBDs) in air. The method in this study was developed as a pre-treatment for electroless plating using DBDs, and is a dry process featuring fewer processing steps and more environmentally friendliness than the chemical method. After ABS surfaces were modified, surface morphologies were observed using a scanning electron microscope (SEM) to check for any physical changes of the surfaces. Cross-sectional SEM images were taken to observe the binding characteristics between metallic films and ABS after metal plating. According to the SEM images, the depths of ABS by plasma are shallow compared to those modified by chemically treatment. The static contact angles were measured with deionized (DI) water droplets on the modified surfaces in order to observe for any changes in chemical activities and wettability. The surfaces modified by plasma showed smaller contact angles, and their modified states lasted longer than those modified by chemical etching. Adhesion strengths were measured using 3M tape (3M 810D standard) and by 90° peel-off tests. The peel-off test revealed the stronger adhesion of the Ni films on the plasma-modified surfaces than on the chemically modified surfaces. Thermal shock test was performed by changing the temperature drastically to see if any detachment of Ni film from ABS would occur due to the differences in thermal expansion coefficients between them. Only for the plasma-treated samples showed no separation of the Ni films from the ABS surfaces in tests. The adhesion strengths of metallic films on the ABS processed by the method developed in this study are better than those of the chemically processed films.