Design and Application of Thermal Vapor Compressor for Multi-Effect Desalination Plant (열증기압축기 설계와 MED 담수설비에의 적용)

  • Park, Il-Seok;Park, Sang-Min;Ha, Ji-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1670-1675
    • /
    • 2004
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape. mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element, In this paper, the experimental results for Various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in comparing with CFD results. The two results show a good agreement with each other within 3.5 % accuracy with regard to the entrainment ratio.

  • PDF

A Study on the Insulation Design Parameters of the Reactor in the Korean Standard Nuclear Power Plant (한국표준원전 원자로용기의 단열 설계에 관한 연구)

  • 김석범;백세진;임덕재;최해윤;이상섭;박종호
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.285-292
    • /
    • 1999
  • The design parameter of the reactor vessel insulation for the Korea Standard Power Plant has been studied numerically. The heat loss from the reactor vessel through the insulation is analysed by using the computational fluid dynamics code, FLUENT. Parametric study has been performed on the air gap width between the reactor vessel wall and the inner surface of the insulation, and on the insulation thickness. Also evaluated is the performance degradation due to the chimney effect caused by gaps between the panels during the installation of the insulation system. From the analysis results, the optimal air gap width and the optimal insulation thickness are obtained.

  • PDF

Histopathological Comparison of Animal Models of Skin Inflammation and Inhibition of the Inflammatory Responses by Plant Flavonoid, Wogonin

  • Kim, Hyun-Pyo
    • Biomolecules & Therapeutics
    • /
    • v.13 no.3
    • /
    • pp.133-137
    • /
    • 2005
  • Wogonin(5,7-dihydroxy-8-methoxyflavone), an anti-inflammatory plant flavonoid, was previously demonstrated to modulate the several parameters of animal skin inflammation. This compound inhibited edematic response as well as proinflammatory gene expression. In this investigation, the histopathological changes of the lesions from different types of experimental skin inflammation were compared and the potential therapeutic effect of topically applied wogonin was evaluated. From the results, it was found that multiple TPA treatment drastically increased ear edema accompanied with epidermal hyperplasia and inflammatory cell infiltration, while phenol treatment provoked only edematic response in the dermal area. Wogonin somewhat differently inhibited these animal models of skin inflammation.

A Real-time Calculation Method on Performance Impact of Controllable Operation Parameters for Combined Cycle rower Plant (복합화력 제어가능 운전 파라미터의 실시간 영향산출 기법)

  • Joo Yong-Jin;Park Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.67-73
    • /
    • 2006
  • A calculation method on performance impact of the controllable operations parameter such as GT inlet filter ${\Delta}P$, compressor efficiency, and condenser pressure was devised to achieve best performance of combined cycle power plant with the on-line performance monitoring system. This method calculates the performance impact on the deviation between 'Expected' values and 'Actual' values. Controllable parameter targets are determined based on achievable performance given existing equipments and control conditions.

Control Method for State Constrained Control Systems: Dynamic Anti-Widup Based Approach (동적 와인드엎 방지법에 기초한 상태 제한이 존재하는 시스템의 제어 방법)

  • Park, Jong-Koo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.8
    • /
    • pp.672-681
    • /
    • 2000
  • Based on the dynamic anti-windup strategy a novel control methodology for state constrained control systems is presented. First a linear controller is designed for an open-loop stable plant to show a desirable nominal performance by ignoring state constraints. And then an additional dynamic compensator is introduced to preserve the nominal performance as closely as possible int he face of state constraints. This paper focuses on the second step under the assumption that a linear controller has already been designed appropriately by using an effective controller design method. By minimizing a reasonable performance index the dynamic compensator is derived explicitly which is expressed int he plant and controller parameters. the proposed method not only guarantees the total stability of the overall resulting systems but also provides desirable output performance because it solves the state-positioning problem completely.

  • PDF

EVALUATION OF NIRS FOR ASSESSING PHYSICAL AND CHEMICAL CHARACTERISTICS OF LINEN WEFT YARN

  • Sharma, Hss;Kernaghan, K.;Whiteside, L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1091-1091
    • /
    • 2001
  • Previous reports have shown that Near Infrared Spectroscopy (NIRS) can be used to assess physical and chemical properties of flax fibre and fabric quality. Currently, spinners assess yarn quality mainly based on strength and regularity measurements. There two key characteristics are influenced by quality of raw fibres used, especially the degree of rotting and strength. The aim of this investigation was to evaluate the use of NIRS for assessing quality of weft grade yarn available on the commercial market. In order to develop the NIR calibrations, a range of samples representing poor, medium and good quality weft yarn samples was included in the calibration and validation sample sets. The samples were analysed for physical and chemical parameters including caustic weight loss, fibre fractions, lipid, ash and minerals. A detailed protocol for assessing yarn quality has been developed to maximize the accuracy of the reflectance spectra. The development of partial least squares regression models and validation of the calibration equations using blind samples will be presented and discussed.

  • PDF

Identification of a Parametric ARX Model of a Steam Generation and Exhaust Gases for Refuse Incineration Plants (소각 프린트의 증기발생 및 배기가스에 대한 파라메트릭 ARX 모델규명)

  • Hwang, Lee-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.7
    • /
    • pp.556-562
    • /
    • 2002
  • This paper studies the identification of a combustion model, which is used to design a linear controller of a steam generation quantity and harmful exhaust gases of a Refuse Incineration Plant(RIP). Even though the RIP has strong nonlinearities and complexities, it is identified as a MIMO parametric ARX model from experimental input-output data sets. Unknown model parameters are decided from experimental input-output data sets, using system identification algorithm based on Instrumental Variables(IV) method. It is shown that the identified model well approximates the input-output combustion characteristics.

A Study on the Bidding Strategies of Combined Cycle Plants in a Competitive Electricity Market (경쟁적 전력시장에서 복합화력발전의 입찰전략에 대한 연구)

  • Kim, Sang-Hoon;Lee, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.694-699
    • /
    • 2009
  • Combined cycle plants which feature distinct advantages for power generation such as fast response, high efficiency, environmental friendliness, fuel flexiblity represent the majority of new generating plant installations across the globe. Combined cycle plants have different operating modes where the operating parameters can differ greatly depending which mode is operating at the time. This paper addresses the bidding strategy model of combined cycle plants in a competitive electricity market by using a characteristic of multiple operating modes of combined cycle plants. Simulation results of case studies show that an operating mode among multiple ones is selected strategically in generation bidding for more profit of generation company.

Evaluation of the Ductile-Brittle Transition Behavior of fracture Toughness by Material Degradation (열화에 따른 파괴인성치의 연성-취성 천이거동 평가)

  • 석창성;김형익;김상필
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.140-147
    • /
    • 2003
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time at a high temperature, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sized specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

Experimental study on the capacity of pilot scale FBC for paper sludge (Pilot plant 규모 유동충 소각로의 제지 슬러지 소각 용량에 관한 실험적 연구)

  • La, Seung-Hyuck;Moon, Dong-Jin;Kang, Kyung-Tae;Shin, Dong-Hoon;Hwang, Jung-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.199-203
    • /
    • 2002
  • In this paper, the effects of water contents on combustion characteristics of paper sludge and capacity of fluidized bed combustor(FBC) were investigated using 0.26m diameter, 1.75m height pilot-plant scale combustor. Combustion tests of paper sludge containing water contents between 40wt% and 50wt% were performed. The temperature and emission variation, the pressure inside combustor were measured to monitor the fluidization quality. The experimental results showed that 30kg/hr feeding rate of sludge containing water up to 45wt% was preferable for this system. Sludge loading rate, heat release rate were calculated from experimental data as major parameters showing FBC capacity. Comparsion with sludge loading rate from other source was also performed

  • PDF