• 제목/요약/키워드: plant parameters

검색결과 1,814건 처리시간 0.031초

자가용 발전기 모델 정수 결정 (Determination of Co-generator Model Parameters)

  • 김동준;김학만;전영환;김지원;전진홍;국경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.236-240
    • /
    • 2001
  • This paper presents the derivation of model parameters against a comparatively small industrial power plant, and validates its model parameters using the stored data measured at the time of on-site generator characteristic testing. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. Those of the comparisons between measured results and simulation results show good match.

  • PDF

하수의 염소 소독시 총잔류염소 감소 특성에 관한 연구 (Studies on Chlorine Demand and Its Decay Kinetics in Chlorinated Sewage Effluents)

  • 백영석;손진식
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.176-183
    • /
    • 2005
  • Chlorination of wastewater is recently practiced in Korea. While many researchers have studied the kinetics of aqueous chlorine(HOCl) with nitrogeneous compounds and other organic/inorganic contaminants in drinking water, the researches of wastewater chlorination are relatively few. The purpose of this study was to investigate the chlorine decay kinetics and parameters on wastewater chlorination. Chlorine decay rate increased with increasing initial chlorine concentration. The parameters affecting chlorine decay rate were different in each wastewater treatment plant. One of the most important parameters affecting chlorine decay was initial chlorine concentration, and other parameters such as $NH_3-N$, total coliform, $UV_{254}$ and Fe were also affected. The decay ratio of chlorine was decreased with increasing initial chlorine concentration, and the disinfection efficiency showed good correlation with the decay ratio.

서천화력 발전기 및 제어시스템 모델링 (Power Generation Unit Modelling in Thermal Power Plant)

  • 김용학;김태균;추진부;주준영;송석하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.15-18
    • /
    • 2003
  • This paper provides the procedure to derive model parameters from the field tests. Since the accuracy of power system analysis depends on the accuracy of models used to represent the generation units, the reliability of power system analysis could be affected by parameters used in those models. The objective of this paper is to validate and update the models. So the field test had performed for thermal units and adjusting the variables to match with the measured values derived their model parameters. And the model parameters are verified by comparing the variables between models.

  • PDF

USN 기술 기반의 비접촉 식물 생장 측정 시스템 구현 (Implementation of Non-contact Plant Growth Measurement System based on USN Technologies)

  • 석진원;유인태
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권10호
    • /
    • pp.137-145
    • /
    • 2010
  • 본 논문은 USN(Ubiquitous Sensor Network) 기술 기반의 적외선 센서를 사용한 비접촉식 식물 생장 측정 시스템을 제안한다. 제안된 시스템은 식물 생장을 측정할 때 식물의 생장 피해를 줄이기 위하여 비접촉 센서를 사용하였다. 이 시스템은 직경, 단면적, 비대 형상과 같은 식물 생장 요소를 실시간 비접촉 방식으로 측정할 수 있다. 측정된 데이터는 센서 네트워크 기술을 사용하여 원격 서버까지 전송되고, 서버에서 저장 및 분석되며, 최종적으로 분석된 데이터는 사용자에게 제공될 수 있도록 구성하였다. 본 논문에서 제안된 식물 생장 측정시스템은 측정 방식과 장치에 비접촉 적외선 센서를 사용하여 설계 및 구현을 하였다. 그리고 시스템의 성능은 필드에서 측정 실험을 통하여 검증해 보았다.

냉각공기 예냉각을 통한 가스터빈 설계변수 변화에 의한 복합발전시스템 성능향상 분석 (Analysis of Performance Enhancement of a Combined Cycle Power Plant by the Change of Design Parameters of Gas Turbine Using Coolant Pre-cooling)

  • 권현민;김동섭;강도원;손정락
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.61-67
    • /
    • 2016
  • Turbine blade cooling is one of the major technologies to enhance the performance of gas turbine and combined cycle power plants. In this study, two cases of coolant pre-cooling schemes were applied in combined cycle power plant: decrease of coolant mass flow needed to cool turbine blade and increase of turbine inlet temperature (TIT). Both schemes are benefited by the decrease of coolant temperature through coolant pre-cooling. Under the same degree of pre-cooling, increasing TIT exhibits larger plant power boost and higher plant efficiency than reducing coolant flow. As a result, the former produces the same gas turbine power with a much smaller degree of pre-cooling than the latter. Another advantage of increasing TIT is a higher plant efficiency. Even with an assumption of partial achievement of the theoretically predicted TIT, the method of increasing TIT can provide considerably larger power output.

Biocontrol of Late Blight and Plant Growth Promotion in Tomato Using Rhizobacterial Isolates

  • Lamsal, Kabir;Kim, Sang Woo;Kim, Yun Seok;Lee, Youn Su
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권7호
    • /
    • pp.897-904
    • /
    • 2013
  • Seven bacterial isolates (viz., AB05, AB10, AB11, AB12, AB14, AB15, and AB17) were derived from the rhizosphere and evaluated in terms of plant growth-promoting activities and the inhibition of Phytophthora infestans affecting tomatoes in Korea. According to 16S rDNA sequencing, a majority of the isolates are members of Bacillus, and a single isolate belongs to Paenibacillus. All seven isolates inhibited P. infestans by more than 60% in vitro. However, AB15 was the most effective, inhibiting mycelial growth of the pathogen by more than 80% in vitro and suppressing disease by 74% compared with control plants under greenhouse conditions. In a PGPR assay, all of the bacterial isolates were capable of enhancing different growth parameters (shoot/root length, fresh biomass, dry matter, and chlorophyll content) in comparison with non-inoculated control plants. AB17-treated plants in particular showed the highest enhancement in fresh biomass with 18% and 26% increments in the root and shoot biomass, respectively. However, isolate AB10 showed the highest shoot and root growth with 18% and 26% increments, respectively. Moreover, the total chlorophyll content was 14%~19% higher in treated plants.

Genotype-Environment Interaction and Stability Analysis for Yield and Yield Contributing Characters in Soybean(Glycine max L.)

  • Islam, Mohammad Saiful;Newaz, Muhammad Ali;Islam, Md. Jahidul;Heo, Seong-Il;Wang, Myeong-Hyeon
    • 한국자원식물학회지
    • /
    • 제20권6호
    • /
    • pp.504-510
    • /
    • 2007
  • GE interaction is the expression of differential genotypic adaptation across environments. GE interactions through different stability parameters and performance of the traits of genotypes were studied. The traits were days to maturity, pod length, number of pods/ plant, 100-seed weight and seed yield/plant in ten soybean genotypes across five environments. Significant differences were observed for genotypes, environments and GE interactions. Stability analysis after Eberhart and Russell's model suggested that the genotypes used in this study were all more or less responsive to environmental changes. Most of the genotypes perform better in Env.3. Based on phenotypic indices(Pi), regression ($S^2di$) genotype Garurab was found fairly stable for days to maturity. BS-23 and G-2120 may be considered as stable genotype for pod length. All the genotypes except G-2120 showed that the genotypes were relatively unstable under environmental fluctuation for the number of pod/plant. Genotype BS-23 was found most stable among all the genotypes for 100-seed weight. BS-3 and Gaurab was the most stable and desirable genotypes for seed yield in soybean.

The application of machine learning for the prognostics and health management of control element drive system

  • Oluwasegun, Adebena;Jung, Jae-Cheon
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2262-2273
    • /
    • 2020
  • Digital twin technology can provide significant value for the prognostics and health management (PHM) of critical plant components by improving insight into system design and operating conditions. Digital twinning of systems can be utilized for anomaly detection, diagnosis and the estimation of the system's remaining useful life in order to optimize operations and maintenance processes in a nuclear plant. In this regard, a conceptual framework for the application of digital twin technology for the prognosis of Control Element Drive Mechanism (CEDM), and a data-driven approach to anomaly detection using coil current profile are presented in this study. Health management of plant components can capitalize on the data and signals that are already recorded as part of the monitored parameters of the plant's instrumentation and control systems. This work is focused on the development of machine learning algorithm and workflow for the analysis of the CEDM using the recorded coil current data. The workflow involves features extraction from the coil-current profile and consequently performing both clustering and classification algorithms. This approach provides an opportunity for health monitoring in support of condition-based predictive maintenance optimization and in the development of the CEDM digital twin model for improved plant safety and availability.

국내 무연탄 발전소 역청탄 사용시 탈황 특성 연구 (Desulfurization Characteristics for Anthracite Coal Power Plant by Increasing Bituminous Coal Fuel)

  • 김정유;문승재;이재헌
    • 플랜트 저널
    • /
    • 제4권4호
    • /
    • pp.71-77
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the sudden rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Taldinsky Mine in Russia. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Yong Dong thermal power plant.

  • PDF

심지형 가습장치를 이용한 식물바이오필터의 토양수분 및 식물 생육의 안정성 (Stabilization of Soil Moisture and Plant Growth on a Botanical Biofilter with a Wick-Typed Humidifying Apparatus)

  • 김유나;천만영;이창희
    • 한국자원식물학회지
    • /
    • 제29권5호
    • /
    • pp.579-587
    • /
    • 2016
  • 본 연구의 최종 목표는 심지가습장치를 이용하여 소형화된 식물바이오필터를 개발함으로써 토양수분을 안정화하고, 이 바이오필터에 의해 실내공기의 오염 물질을 정화하는 것이다. 심지자동가습기가 장착된 신규 식물바이오필터는 2015년에 만든 대형바이오필터에서 흡수탑 가습장치를 제거하여 더 소형화된 디자인으로 제작하였다. 본 연구는 신규 바이오필터 내부의 가습장치에 심지의 수를 조절함에 따른 식재층간의 토양수분 변화를 비교하고, 이 바이오필터의 식재층에 스파티필름 (Spathiphyllum wallisii ‘Mauna Loa’)을 식재하기 전과 후의 토양수분 변화와 식물 생육을 비교하였다. 심지의 개수에 따른 식재층간 토양수분은 비슷하게 나타났으며, 모든 토양수분의 선형회귀선은 장기간 토양수분이 안정화되었기 때문에 거의 수평의 선을 나타내었다. S. wallisii ‘Mauna Loa’의 식재 전과 식재 후 30일째의 생육 지표를 비교한 결과, 모든 생육 지표에 있어 통계적 유의성이 없었다. 따라서, 식물바이오필터의 토양수분 함량은 흡수탑 가습장치를 사용한 이전의 바이오필터보다 심지의 개수에 관계없이 심지가습장치를 적용하였을 때 보다 안정화 되었다.