Aging Effect Management for Class 1 Piping of PWR (가압경수로 원전 안전 1등급 배관의 노화영향 관리)

  • Chang, Y.S.;Jin, T.E.;Song, T.H.;Jeong, I.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.316-321
    • /
    • 2001
  • A previous feasibility study for the Korean lead plant, PLiM Phase I, showed a strong possibility of continued operation beyond the original licensed period. In 1998, PLiM Phase II study was initiated aimed at performing additional detailed evaluations on a wider range of components. The objective of this paper is to present the Korean PLiM efforts for Class 1 piping which is identified as one of the critical components with regard to long-term operation. The key findings such as typical design features, degradation mechanisms, technical issues, draft results from the lifetime evaluation for Class 1 piping of the lead plant are briefly described.

  • PDF

The operation Characteristic of Pilot-scale 2-Stage Coal gasifier (Pilot 규모 2단 형상 가스화기 운전특성 실험)

  • Hong, Jin-Pyo;Chung, Jae-Hwa;Seo, Seok-Bin;Chi, Jun-Hwa;Lee, Seung-Jun;Chung, Suk-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.528-532
    • /
    • 2009
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of gasification process to type and structure of gasifier. For this purpose, the performance characteristics of gasification reaction are analyzed with the operation characteristic of pilot-scale 2-stage coal gasifier. It is found that gasification reaction, floating characteristic of melted slag, particle stick of inside of the gasifier, particle stick and deposit of Syngas cooler are the causes in the different performance characteristics.

  • PDF

PERIODIC SAFETY REVIEW ON KORI UNIT 1 (고리 1호기 주기적안전성 평가)

  • Kim, Tae-Ryong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.403-414
    • /
    • 2003
  • Periodic safety review on Kori Unit 1 has been successfully done for the first time in Korea. 11 safety factors of the review were fully evaluated in accordance with the domestic legal system. Although it is the oldest nuclear power plant in Korea, Kori Unit 1 was found to have maintained good operating conditions and continuously enhanced its safety by implementing post-TMI action plans and other safety issues, such as replacing steam generators and process/control system. It can be therefore confirmed that safe operation of Kori Unit 1 is guaranteed until next periodic safety review. Nevertheless, some corrective action items were recommended to enhance further its safety level, such as equipment qualification, additional ageing management program, strengthening of some procedures related to administration and human factor. The results of PSR can be utilized for the continued operation beyond the design life as long as the plant safety is maintained and improved. Experiences of the PSR on Kori Unit 1 can be also applied to PSR on other plants.

  • PDF

Analysis of the $CO_2$ emission amount and characteristics of combined heat and power plants in industrial complex by using the fuel analysis method (연료분석 방법을 적용한 산업단지 열병합발전소 이산화탄소 배출량 및 배출특성분석)

  • Kang, Seok-Hun;Chung, Dae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1243-1248
    • /
    • 2008
  • $CO_2$ emission amount and characteristics of combined heat and power (CHP) plant in industrial complex of Korea is evaluated by using the fuel analysis method. Fuel analysis methods of several foreign countries and developed one which is developed considering the operation characteristics of the surveyed CHP plants are used. The operation data is surveyed for all of the CHP plants in industrial complex and is composed of fuel consumption amount, generation, sale and efficiency of heat and electricity, condensed steam enthalpy, and etc of the each CHP.

  • PDF

Comparison between ISO 9000 Specification and Nuclear Quality Assurance Specification and Expected Application Effect (ISO 9000규격과 원자력품질보증 규격과의 비교 및 예상 적용 효과)

  • Lee, Tae-Hoon;Ha, Ji-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.3
    • /
    • pp.79-89
    • /
    • 2011
  • Since commercial operation of Kori-1 nuclear power plant in 1978, twenty units are under operation and six units are under construction at 2011 present. Nuclear power become a main energy source in our country. However, the plant was constructed by a USA vendor in its beginning period, the Quality Assurance requirements of USA was applied. Even though Quality Assurance requirements were newly established to the Korea Atomic Energy Act, its contents are quite similar to those of USA. And 10 CFR 50 App.B, ASME NQA-1 apply to most of nuclear industries as a quality assurance plan. In this paper, Quality Assurance requirement of domestic nuclear industries has been investigated and applicable method of ISO Quality Assurance application to the nuclear industries is suggested by a comparison ISO 9000 and nuclear quality assurance specification.

The Study of Improvement in Reactor Thermal Power Measurement Method using KALMAN FILTER (KALMAN FILTER를 이용한 원자로 열출력측정 방법개선에 관한 고찰)

  • 정남교
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.5
    • /
    • pp.82-95
    • /
    • 1997
  • A Study of Improvement in Reactor Thermal Power Measurement Method using Kalman Filter. The objectives of the safety analysis of nuclear power plants are to maintain the surface temperature of fuel and fuel cladding within limit value in case of Loss of Coolant accident (LOCA) so that it ensures the safety and reliability of nuclear power plants. The new technique evaluating the reactor power and improvement of existing plant system increase the safety margin of nuclear power plant operation, and accordingly, economic effect will be anticipated. Hereby, 1 would like to introduce reactor power measurement method using Kalman filter that enables to calculate the reactor power more precisely combining the parameters, for example, turbine output as the 1 st stage pressure of high pressure turbine, and reactor power using energy equilibrium relation. It is expected that the new technique will enhance the accuracy of measurement of reactor power and maintain the reliability of nuclear power operation by increasing operational safety margin, and gain the economic benefit

  • PDF

The Development of Graphic Display and Operator Console System for Monitoring the Operation of Power Plant (발전소 운전 감시용 그래픽 디스플례이 및 오퍼레이터 console 시스템의 개발)

  • Cho, Y.J.;Moon, B.C.;Kim, B.K.;Youn, M.J.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.216-220
    • /
    • 1987
  • A graphic display and operator console system is developed for monitoring the operation of power plant. It has multiprocessor structure using VME bus and common memory. The graphic monitoring system is applied to fault tolerant control system for enhancing reliability of boiler analog controller. As a result, it displays all the operating date as color graphic images with 14 pages. Moreover, it can transfer the operator commands to the other micro-processors through common memory.

  • PDF

Efficiency Calculation of Operating Induction Motors in Plant (플랜트에서 운전 중인 유도전동기의 효율 계산)

  • Park, Hyung-Joon;Chung, Chan-Soo;Lee, Hae-Soo;Lee, Sang-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2046-2047
    • /
    • 2007
  • This paper is about the energy efficiency calculation of operating electric motors in production facilities. The most important 1st step to efficient operation of plants is the evaluation of the energy efficiency of the production facilities in that plant. Through this procedure, we can decide that which facilities i.e. induction motors, in this paper, should do maintenance or not. There are mainly 2 types of energy which are used in production facilities, the one is electric energy and the other is heat energy but in order to make calculation simple, in this paper, we are only focusing on electric energy, efficiency and energy loss of the electric motors under operation conditions. As a case study, we chose electric motors in a certain process in a production facilities, and calculated efficiency and loss by using measured data.

  • PDF

Dynamic Matrix Control of Grade Change Operations in Paper Mills (제지공정의 모델예측제어)

  • 박종호;여영구;강홍
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2004.11a
    • /
    • pp.212-220
    • /
    • 2004
  • In this work the Dynamic Matrix Control method is applied to control the grade change operations in paper mills. Paper process trained by neural network regards a real-plant. The model obtained with operation data is used to achieve DMC. Results of simulations for DMC control of grade change operations are compared with plant operation data response. From the comparison, we can see that the proposed DMC method exhibits faster response for the grade change of paper and achieves stable steady-state.

  • PDF

A study on advanced treatment of domestic wastewater nutrient removal by using Biosorption (생흡착을 이용한 생활하수의 염양염류제거에 관한 고도처리 연구)

  • Park, Ju-Seok;Kim, Hyun-Kab;An, Chang-Hwan;Whang, Jung-Ki;Ahn, Sang-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.29-35
    • /
    • 1999
  • The purpose of this study is to remove the organics, nitrogen and phosphorus using biosorption for the domestic sewage. The new process using biosorption is based on the methods of contact-stabilization, which remove the organics by absorbing them to the surface of the microorganism in the activated sludge. This process consists of biosorption reactor, biosorption clarifier, nitrifying reactor, nitrifying clarifier, denitrifying reactor, phosphorus uptake(polishing) reactor and final clarifier. The efficiency of removal could be reached 91% for organics, 76% for nitrogen, 90% for phosphorus in Eujungbu pilot plant. We operated the plant which irrigated $10m^3$ per day for sewage. During our operation the HRT(Hydraulic Retention time) was maintained for 10.5hr, but it could be reduced as 8.5hr according to our operation results.

  • PDF